COMPARISON OF TESTS FOR GLYCATED HEMOGLOBIN AND FASTING AND 2 HOUR PLASMA-GLUCOSE CONCENTRATIONS AS DIAGNOSTIC METHODS FOR DIABETES

被引:392
|
作者
MCCANCE, DR
HANSON, RL
CHARLES, MA
JACOBSSON, LTH
PETTITT, DJ
BENNETT, PH
KNOWLER, WC
机构
[1] NIDDKD,PHOENIX EPIDEMIOL & CLIN RES BRANCH,DIABET & ARTHRITIS EPIDEMIOL SECT,PHOENIX,AZ 85014
[2] NIAMSD,PHOENIX,AZ 85014
来源
BRITISH MEDICAL JOURNAL | 1994年 / 308卷 / 6940期
关键词
D O I
10.1136/bmj.308.6940.1323
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To compare the ability of tests measuring two hour plasma glucose, fasting plasma glucose, and glycated haemoglobin concentrations in predicting the specific microvascular complications of non-insulin dependent diabetes mellitus. Design-Cross sectional and longitudinal analysis of the relation between complications and concomitant results of the three tests. Setting-Gila River Indian Community, Arizona. Subjects-Pima Indians (cross sectional, n=960), aged 25 years or above who were not receiving insulin or oral hypoglycaemic treatment at the baseline examination. Main outcome measures-Developement of retinopathy and nephropathy. Results-Cross sectionally, frequency distributions of logarithms of the three sets of results were bimodal, with the prevalence of retinopathy and nephropathy being, respectively, 12.0-26.7 and 3.9-4.2 times as high above as below cut off points which minimised overlap (two hour plasma glucose concentration 12.6mmol/l; fasting plasma glucose concentration 9.3mmol/l; glycated haemoglobin (HbA(1c)) concentration 7.8%). Longitudinally, each of the three measures of glycaemia significantly predicted the development of retinopathy (P<0.0001) and nephropathy (P<0.05). Receiver operating characteristic curves showed that two hour plasma glucose concentration was superior to fasting plasma glucose concentration (P<0.05) for prevalent cases of retinopathy, but otherwise no variable had a significant advantage for detecting incident or prevalent cases of either complication. Conclusions-These findings suggest that determination of glycated haemoglobin or fasting plasma glucose concentrations alone may be acceptable alternatives to measuring glucose concentration two hours after challenge with 75g glucose for the diagnosis of diabetes.
引用
收藏
页码:1323 / 1328
页数:6
相关论文
共 50 条
  • [41] FASTING HYPERGLYCEMIA STUDY - TARGETED SCREENING BY 2 FASTING PLASMA-GLUCOSE MEASUREMENTS
    HAMMERSLEY, MS
    MCLELLAN, JAS
    MEYER, LC
    MANLEY, SE
    CHRISTOPHER, P
    TURNER, RC
    HOLMAN, RR
    DIABETOLOGIA, 1993, 36 : A176 - A176
  • [42] COMPARATIVE CLINICAL RELIABILITY OF FASTING PLASMA-GLUCOSE AND GLYCOSYLATED HEMOGLOBIN IN NON-INSULIN-DEPENDENT DIABETES-MELLITUS
    PECORARO, RE
    KOEPSELL, TD
    CHEN, MS
    LIPSKY, BA
    BELCHER, DW
    INUI, TS
    DIABETES CARE, 1986, 9 (04) : 370 - 375
  • [43] Utility of Screening Fasting Plasma Glucose and Glycated Hemoglobin to Circumvent the Need for Oral Glucose Tolerance Test in Women with Prior Gestational Diabetes
    Goyal, Alpesh
    Gupta, Yashdeep
    Kubihal, Suraj
    Kalaivani, Mani
    Bhatla, Neerja
    Tandon, Nikhil
    ADVANCES IN THERAPY, 2021, 38 (02) : 1342 - 1351
  • [44] Utility of Screening Fasting Plasma Glucose and Glycated Hemoglobin to Circumvent the Need for Oral Glucose Tolerance Test in Women with Prior Gestational Diabetes
    Alpesh Goyal
    Yashdeep Gupta
    Suraj Kubihal
    Mani Kalaivani
    Neerja Bhatla
    Nikhil Tandon
    Advances in Therapy, 2021, 38 : 1342 - 1351
  • [45] GENETIC ANALYSES OF 2-HOUR PLASMA-GLUCOSE LEVELS
    YAMASHITA, TS
    MACKAY, WL
    RUSHFORTH, NB
    HOUSER, HB
    CLINICAL RESEARCH, 1983, 31 (04): : A741 - A741
  • [46] EFFECTS OF FASTING, ELEVATED PLASMA-GLUCOSE AND PLASMA-INSULIN CONCENTRATIONS ON MILK SECRETION IN WOMEN
    NEVILLE, MC
    SAWICKI, VS
    HAY, WW
    JOURNAL OF ENDOCRINOLOGY, 1993, 139 (01) : 165 - 173
  • [47] Fasting plasma glucose diagnostic criteria for diabetes mellitus
    Wiener, K
    Roberts, NB
    DIABETIC MEDICINE, 1999, 16 (11) : 970 - 970
  • [48] Glucose tolerance and cardiovascular mortality -: Comparison of fasting and 2-hour diagnostic criteria
    Borch-Johnsen, K
    Neil, A
    Balkau, B
    Larsen, S
    Nissinen, A
    Pekkanen, J
    Tuomilehto, J
    Jousilahti, P
    Lindstrom, J
    Pyörälä, M
    Pyörälä, K
    Eschwege, E
    Gallus, G
    Garancini, MP
    Bouter, LM
    Dekker, JM
    Heine, RJ
    Nijpels, HG
    Stehouwer, CDA
    Feskens, EJM
    Kromhout, D
    Peltonen, M
    Pajak, A
    Eriksson, J
    Qiao, Q
    ARCHIVES OF INTERNAL MEDICINE, 2001, 161 (03) : 397 - 405
  • [49] FASTING PLASMA-GLUCOSE - A POOR DETECTOR OF ASYMPTOMATIC DIABETES - THE ISRAEL GOH STUDY
    MODAN, M
    HALKIN, H
    KARASIK, A
    DIABETOLOGIA, 1984, 27 (02) : A311 - A311
  • [50] SENSITIVITY OF FASTING PLASMA-GLUCOSE IN DIAGNOSING DIABETES IN EPIDEMIOLOGIC STUDIES - ETHNIC COMPARISONS
    ROSENTHAL, M