COMPARISON OF TESTS FOR GLYCATED HEMOGLOBIN AND FASTING AND 2 HOUR PLASMA-GLUCOSE CONCENTRATIONS AS DIAGNOSTIC METHODS FOR DIABETES

被引:392
|
作者
MCCANCE, DR
HANSON, RL
CHARLES, MA
JACOBSSON, LTH
PETTITT, DJ
BENNETT, PH
KNOWLER, WC
机构
[1] NIDDKD,PHOENIX EPIDEMIOL & CLIN RES BRANCH,DIABET & ARTHRITIS EPIDEMIOL SECT,PHOENIX,AZ 85014
[2] NIAMSD,PHOENIX,AZ 85014
来源
BRITISH MEDICAL JOURNAL | 1994年 / 308卷 / 6940期
关键词
D O I
10.1136/bmj.308.6940.1323
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To compare the ability of tests measuring two hour plasma glucose, fasting plasma glucose, and glycated haemoglobin concentrations in predicting the specific microvascular complications of non-insulin dependent diabetes mellitus. Design-Cross sectional and longitudinal analysis of the relation between complications and concomitant results of the three tests. Setting-Gila River Indian Community, Arizona. Subjects-Pima Indians (cross sectional, n=960), aged 25 years or above who were not receiving insulin or oral hypoglycaemic treatment at the baseline examination. Main outcome measures-Developement of retinopathy and nephropathy. Results-Cross sectionally, frequency distributions of logarithms of the three sets of results were bimodal, with the prevalence of retinopathy and nephropathy being, respectively, 12.0-26.7 and 3.9-4.2 times as high above as below cut off points which minimised overlap (two hour plasma glucose concentration 12.6mmol/l; fasting plasma glucose concentration 9.3mmol/l; glycated haemoglobin (HbA(1c)) concentration 7.8%). Longitudinally, each of the three measures of glycaemia significantly predicted the development of retinopathy (P<0.0001) and nephropathy (P<0.05). Receiver operating characteristic curves showed that two hour plasma glucose concentration was superior to fasting plasma glucose concentration (P<0.05) for prevalent cases of retinopathy, but otherwise no variable had a significant advantage for detecting incident or prevalent cases of either complication. Conclusions-These findings suggest that determination of glycated haemoglobin or fasting plasma glucose concentrations alone may be acceptable alternatives to measuring glucose concentration two hours after challenge with 75g glucose for the diagnosis of diabetes.
引用
收藏
页码:1323 / 1328
页数:6
相关论文
共 50 条
  • [31] Fasting plasma glucose and glycated haemoglobin in the screening of diabetes and impaired glucose tolerance
    Mannucci, E
    Ognibene, A
    Sposato, I
    Brogi, M
    Gallori, G
    Bardini, G
    Cremasco, F
    Messeri, G
    Rotella, CM
    ACTA DIABETOLOGICA, 2003, 40 (04) : 181 - 186
  • [32] Fasting plasma glucose and glycated haemoglobin in the screening of diabetes and impaired glucose tolerance
    E. Mannucci
    A. Ognibene
    I. Sposato
    M. Brogi
    G. Gallori
    G. Bardini
    F. Cremasco
    G. Messeri
    C. M. Rotella
    Acta Diabetologica, 2003, 40 : 181 - 186
  • [33] Diabetes diagnostic thresholds of the glycated hemoglobin A1c and fasting plasma glucose levels considering the 5-year incidence of retinopathy
    Nakagami, Tomoko
    Takahashi, Kanako
    Suto, Chikako
    Oya, Junko
    Tanaka, Yuki
    Kurita, Moritoshi
    Isago, Chisato
    Hasegawa, Yukiko
    Ito, Arata
    Uchigata, Yasuko
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2017, 124 : 20 - 29
  • [34] THE ASSOCIATION BETWEEN FASTING PLASMA GLUCOSE AND GLYCATED HEMOGLOBIN IN THE PRE-DIABETES RANGE AND FUTURE DEVELOPMENT HYPERTENSION
    Geva, M.
    Shlomai, G.
    Berkovich, A.
    Leibowitch, A.
    Maor, E.
    Grossman, E.
    JOURNAL OF HYPERTENSION, 2019, 37 : E66 - E66
  • [35] COULD THE FASTING PLASMA-GLUCOSE ASSAY BE USED TO SCREEN FOR GESTATIONAL DIABETES
    SACKS, DA
    GREENSPOON, JS
    FOTHERINGHAM, N
    JOURNAL OF REPRODUCTIVE MEDICINE, 1992, 37 (11) : 907 - 909
  • [36] PROFILE OF 24-HOUR PLASMA-GLUCOSE AND INSULIN CONCENTRATIONS - THEIR VARIATION WITH 2 METHODS OF TOTAL PARENTERAL-NUTRITION ADMINISTRATION
    FINKELSTEIN, JW
    BOLEY, SJ
    KREAM, J
    COHEN, MI
    ARCHIVES OF SURGERY, 1979, 114 (12) : 1433 - 1437
  • [37] The utility of fasting plasma glucose in predicting glycosylated hemoglobin in type 2 diabetes
    Ai-Lawati, Jawad Ahmed
    Al-Lawati, Alya Murtadah
    ANNALS OF SAUDI MEDICINE, 2007, 27 (05) : 347 - 351
  • [38] GLYCATED HEMOGLOBIN, PLASMA-GLUCOSE AND DIABETIC-RETINOPATHY - CROSS-SECTIONAL AND PROSPECTIVE ANALYSES
    LIU, QZ
    PETTITT, DJ
    HANSON, RL
    CHARLES, MA
    KLEIN, R
    BENNETT, PH
    KNOWLER, WC
    DIABETOLOGIA, 1993, 36 (05) : 428 - 432
  • [39] FASTING PLASMA-GLUCOSE AND GLYCOSYLATED HEMOGLOBIN LEVELS IN THE ASSESSMENT OF DIABETIC CONTROL IN NON-INSULIN-DEPENDENT DIABETES IN THE YOUNG
    JIALAL, I
    JOUBERT, SM
    KENDALL, D
    SOUTH AFRICAN MEDICAL JOURNAL, 1982, 62 (24): : 889 - 891
  • [40] FASTING PLASMA MAGNESIUM CONCENTRATIONS AND GLUCOSE DISPOSAL IN DIABETES
    YAJNIK, CS
    SMITH, RF
    HOCKADAY, TDR
    WARD, NI
    BRITISH MEDICAL JOURNAL, 1984, 288 (6423): : 1032 - 1034