A DISPOSABLE END-TIDAL CO2 DETECTOR TO VERIFY ENDOTRACHEAL INTUBATION

被引:55
|
作者
ANTON, WR
GORDON, RW
JORDAN, TM
POSNER, KL
CHENEY, FW
机构
[1] Respiratory Care Services, University of Washington Medical Center, Seattle
[2] Department of Anesthesiology, University of Washington Medical Center, Seattle
关键词
end-tidal carbon dioxide; endotracheal intubation;
D O I
10.1016/S0196-0644(05)80938-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We compared the performed of the Fenem FEF(TM) endtidal CO2 detector with TRIMED capnometer to verify endotracheal intubation. Design: The FEF(TM) indicates the presence of CO2 by the color change of a chemically treated indicator; the TRIMED uses infrared technology. Both devices were used during 60 intubations. Setting: Intubations during in-hospital emergency situations outside of the operating room were studied. Type of participants: Adult patients undergoing intubation for respiratory failure, CPR, and other airway protection situations were enrolled in the study. Interventions: The TRIMED monitor and FEF(TM) detector were placed in series between the manual resuscitator and the patient's endotracheal tube adapter after endotracheal tube placement. Measurements and main results: We defined the acceptable criterion for detection of CO2 as production of a positive signal within six mannual resuscitator bag breaths. The TRIMED met this criterion in 58 of 60 patients (sensitivity, 0.97) and the FEF(TM) met this criterion in 59 of 60 patients (sensitivity, 0.98). A paired t test showed no statistically significant difference in performance between the two devices. In five of nine cases of intubation during CPR, the color change of the FEF(TM) was described as "subtle." In one CPR case, a positive signal was not obtained by either device. Conclusion: We conclude that the performance of the FEF(TM) CO2 detector is equal to that of the TRIMED monitor for verification of endotracheal intubation in nonCPR situations. Interpretation of FEF(TM) color changes during CPR should be approached with caution until further studies using the FEF(TM) during CPR are completed.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 41 条
  • [31] Paediatric exhaled CO2 detector causes leaks
    Martherus, Tessa
    den Hoed, Annika
    Cramer, Sophie J. E.
    Tan, Ratna N. G. B.
    Hooper, Stuart B.
    te Pas, Arjan B.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2020, 105 (04): : F441 - F443
  • [32] Norepinephrine with dopamine infusion on the end-tidal carbon dioxide (ETco2) pressure in patients with septic shock
    Sazgar, Mohammad
    Golikhatir, Iraj
    Pashaee, Seyedeh Masoomeh
    Tirandaz, Fatemeh
    Firouzian, Abolfazl
    Aminiahidashti, Hamed
    CASPIAN JOURNAL OF INTERNAL MEDICINE, 2021, 12 (04) : 580 - 585
  • [33] A SUDDEN INCREASE IN PARTIAL PRESSURE END-TIDAL CARBON DIOXIDE (PETCO2) AT THE MOMENT OF RETURN OF SPONTANEOUS CIRCULATION
    Pokorna, Milana
    Necas, Emanuel
    Kratochvil, Jaroslav
    Skripsky, Roman
    Andrlik, Michal
    Franek, Ondrej
    JOURNAL OF EMERGENCY MEDICINE, 2010, 38 (05) : 614 - 621
  • [34] The use of end-tidal carbon dioxide (ETCO2) measurement to guide management of cardiac arrest: A systematic review
    Paiva, Edison F.
    Paxton, James H.
    O'Neil, Brian J.
    RESUSCITATION, 2018, 123 : 1 - 7
  • [35] LACK OF CORRELATION BETWEEN END-TIDAL CARBON-DIOXIDE CONCENTRATIONS AND PACO2 IN CARDIAC-ARREST
    BARTON, C
    CALLAHAM, M
    CRITICAL CARE MEDICINE, 1991, 19 (01) : 108 - 110
  • [36] TRANSLARYNGEAL JET VENTILATION AND END-TIDAL PCO2 MONITORING DURING VARYING DEGREES OF UPPER AIRWAY-OBSTRUCTION
    WARD, KR
    MENEGAZZI, JJ
    YEALY, DM
    KLAIN, MM
    MOLNER, RL
    GOODE, JS
    ANNALS OF EMERGENCY MEDICINE, 1991, 20 (11) : 1193 - 1197
  • [37] Control of end-tidal PCO2 reduces middle cerebral artery blood velocity variability:: Implications for physiological neuroimaging
    Harris, AD
    Ide, K
    Poulin, MJ
    Frayne, R
    NEUROIMAGE, 2006, 29 (04) : 1272 - 1277
  • [38] Thoracoscopic sympathectomy: Endobronchial anesthesia vs endotracheal anesthesia with intrathoracic CO2 insufflation
    El-Dawlatly A.
    Al-Dohayan A.
    Riyad W.
    Thalaj A.
    Delvi B.
    Al-Saud S.
    Journal of Anesthesia, 2002, 16 (1) : 13 - 16
  • [39] Data supporting the use of end-tidal carbon dioxide (ETCO2) measurement to guide management of cardiac arrest: A systematic review
    Paiva, Edison F.
    Paxton, James H.
    O'Neil, Brian J.
    DATA IN BRIEF, 2018, 18 : 1497 - 1508
  • [40] Monitoring Transcutaneously Measured Partial Pressure of CO2 During Intubation in Critically III Subjects
    Frerou, Aurelien
    Maamar, Adel
    Rafi, Sonia
    Lhommet, Claire
    Phelouzat, Pierre
    Pontis, Emmanuel
    Reizine, Florian
    Lesouhaitier, Mathieu
    Camus, Christophe
    Le Tulzo, Yves
    Tadie, Jean-Marc
    Gacouin, Arnaud
    RESPIRATORY CARE, 2021, 66 (06) : 1004 - 1015