A DISPOSABLE END-TIDAL CO2 DETECTOR TO VERIFY ENDOTRACHEAL INTUBATION

被引:55
|
作者
ANTON, WR
GORDON, RW
JORDAN, TM
POSNER, KL
CHENEY, FW
机构
[1] Respiratory Care Services, University of Washington Medical Center, Seattle
[2] Department of Anesthesiology, University of Washington Medical Center, Seattle
关键词
end-tidal carbon dioxide; endotracheal intubation;
D O I
10.1016/S0196-0644(05)80938-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We compared the performed of the Fenem FEF(TM) endtidal CO2 detector with TRIMED capnometer to verify endotracheal intubation. Design: The FEF(TM) indicates the presence of CO2 by the color change of a chemically treated indicator; the TRIMED uses infrared technology. Both devices were used during 60 intubations. Setting: Intubations during in-hospital emergency situations outside of the operating room were studied. Type of participants: Adult patients undergoing intubation for respiratory failure, CPR, and other airway protection situations were enrolled in the study. Interventions: The TRIMED monitor and FEF(TM) detector were placed in series between the manual resuscitator and the patient's endotracheal tube adapter after endotracheal tube placement. Measurements and main results: We defined the acceptable criterion for detection of CO2 as production of a positive signal within six mannual resuscitator bag breaths. The TRIMED met this criterion in 58 of 60 patients (sensitivity, 0.97) and the FEF(TM) met this criterion in 59 of 60 patients (sensitivity, 0.98). A paired t test showed no statistically significant difference in performance between the two devices. In five of nine cases of intubation during CPR, the color change of the FEF(TM) was described as "subtle." In one CPR case, a positive signal was not obtained by either device. Conclusion: We conclude that the performance of the FEF(TM) CO2 detector is equal to that of the TRIMED monitor for verification of endotracheal intubation in nonCPR situations. Interpretation of FEF(TM) color changes during CPR should be approached with caution until further studies using the FEF(TM) during CPR are completed.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 41 条
  • [1] VALIDITY OF A DISPOSABLE END-TIDAL CO2 DETECTOR IN VERIFYING ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS AND CHILDREN
    BHENDE, MS
    THOMPSON, AE
    COOK, DR
    SAVILLE, AL
    ANNALS OF EMERGENCY MEDICINE, 1992, 21 (02) : 142 - 145
  • [2] VERIFICATION OF ENDOTRACHEAL-TUBE PLACEMENT WITH COLORIMETRIC END-TIDAL CO2 DETECTION
    MACLEOD, BA
    HELLER, MB
    GERARD, J
    YEALY, DM
    MENEGAZZI, JJ
    ANNALS OF EMERGENCY MEDICINE, 1991, 20 (03) : 267 - 270
  • [3] EVALUATION OF AN END-TIDAL CO2 DETECTOR DURING PEDIATRIC CARDIOPULMONARY-RESUSCITATION
    BHENDE, MS
    THOMPSON, AE
    PEDIATRICS, 1995, 95 (03) : 395 - 399
  • [4] A Novel Method of Distal End-Tidal CO2 Capnography in Intubated Infants: Comparison With Arterial CO2 and With Proximal Mainstream End-Tidal CO2
    Kugelman, Amir
    Zeiger-Aginsky, Dana
    Bader, David
    Shoris, Irit
    Riskin, Arieh
    PEDIATRICS, 2008, 122 (06) : E1219 - E1224
  • [5] COLORIMETRIC END-TIDAL CO2 DETECTOR FOR VERIFICATION OF ENDOTRACHEAL-TUBE PLACEMENT IN OUT-OF-HOSPITAL CARDIAC-ARREST
    HAYDEN, SR
    SCIAMMARELLA, J
    VICCELLIO, P
    THODE, H
    DELAGI, R
    ACADEMIC EMERGENCY MEDICINE, 1995, 2 (06) : 499 - 502
  • [6] Use of Disposable End Tidal Carbon Dioxide Detector Device for Checking Endotracheal Tube Placement
    Jain, H.
    Vargese, C.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2007, 1 (03) : 104 - 109
  • [7] Bedside end-tidal CO2 tension as a screening tool to exclude pulmonary embolism
    Hemnes, A. R.
    Newman, A. L.
    Rosenbaum, B.
    Barrett, T. W.
    Zhou, C.
    Rice, T. W.
    Newman, J. H.
    EUROPEAN RESPIRATORY JOURNAL, 2010, 35 (04) : 735 - 741
  • [8] Pulmonary embolism in Bradford, UK: role of end-tidal CO2 as a screening tool
    Riaz, Imad
    Jacob, Badie
    CLINICAL MEDICINE, 2014, 14 (02) : 128 - 133
  • [9] Can end-tidal CO2 measurement replace arterial partial CO2 in emergency department respiratory distress management?
    Selki, Kudret
    Demir, Mehmet Cihat
    Senguldur, Erdinc
    Erdem, Emre
    Guldal, Hatice
    Tasdemir, Murat
    Kiciroglu, Alp Kaan Furkan
    Bogan, Mustafa
    MEDICINA INTENSIVA, 2024, 48 (09) : 511 - 519
  • [10] Noninvasive monitoring of the response to therapy during diabetic ketoacidosis:: Is end-tidal CO2 useful?
    Tobias, JD
    CRITICAL CARE MEDICINE, 2003, 31 (10) : 2562 - 2563