NONINVASIVE QUANTIFICATION OF REGIONAL BLOOD-FLOW IN THE HUMAN HEART USING N-13 AMMONIA AND DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING

被引:482
作者
HUTCHINS, GD [1 ]
SCHWAIGER, M [1 ]
ROSENSPIRE, KC [1 ]
KRIVOKAPICH, J [1 ]
SCHELBERT, H [1 ]
KUHL, DE [1 ]
机构
[1] UNIV CALIF LOS ANGELES, SCH MED, DIV NUCL MED & BIOPHYS, BIOMED & ENVIRONM SCI LAB, LOS ANGELES, CA 90024 USA
关键词
D O I
10.1016/0735-1097(90)90237-J
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Evaluation of regional myocardial blood flow by conventional scintigraphic techniques is limited to the qualitative assessment of regional tracer distribution. Dynamic imaging with positron emission tomography allows the quantitative delineation of myocardial tracer kinetics and, hence, the measurement of physiologic processes such as myocardial blood flow. To test this hypothesis, positron emission tomographic imaging in combination with N-13 ammonia was performed at rest and after pharmacologically induced vasodilation in seven healthy volunteers. Myocardial and blood time-activity curves derived from regions of interest over the heart and ventricular chamber were fitted using a three compartment model for N-13 ammonia, yielding rate constants for tracer uptake and retention. Myocardial blood flow (K1) averaged 88 ± 17 ml/min per 100 g at rest and increased to 417 ± 112 ml/min per 100 g after dipyridamole infusion (0.56 mg/kg) and handgrip exercise. The coronary reserve averaged 4.8 ± 1.3 and was not significantly different in the septal, anterior and lateral walls of the left ventricle. Blood flow values showed only a minor dependence on the correction for blood metabolites of N-13 ammonia. These data demonstrate that quantification of regional myocardial blood flow is feasible by dynamic positron emission tomographic imaging. The observed coronary flow reserve after dipyridamole is in close agreement with the results obtained by invasive techniques, indicating accurate flow estimates over a wide range. Thus, positron emission tomography may provide accurate and noninvasive definition of the functional significance of coronary artery disease and may allow the improved selection of patients for revascularization. © 1990.
引用
收藏
页码:1032 / 1042
页数:11
相关论文
共 35 条
  • [2] BERGMAN ST, 1978, CIRCULATION, V61, P34
  • [3] QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15
    BERGMANN, SR
    FOX, KAA
    RAND, AL
    MCELVANY, KD
    WELCH, MJ
    MARKHAM, J
    SOBEL, BE
    [J]. CIRCULATION, 1984, 70 (04) : 724 - 733
  • [4] BRACEWELL RN, 1978, FOURIER TRANSFORM IT, P24
  • [5] INTRAVENOUS DIPYRIDAMOLE COMBINED WITH ISOMETRIC HANDGRIP FOR NEAR MAXIMAL ACUTE INCREASE IN CORONARY FLOW IN PATIENTS WITH CORONARY-ARTERY DISEASE
    BROWN, BG
    JOSEPHSON, MA
    PETERSEN, RB
    PIERCE, CD
    WONG, M
    HECHT, HS
    BOLSON, E
    DODGE, HT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (06) : 1077 - 1085
  • [6] COOPER AJL, 1987, J BIOL CHEM, V262, P1073
  • [7] Endo M, 1987, Ann Nucl Med, V1, P1
  • [8] GAMBHIR SS, 1989, J NUCL MED, V30, P359
  • [9] NONINVASIVE ASSESSMENT OF CORONARY STENOSES BY MYOCARDIAL PERFUSION IMAGING DURING PHARMACOLOGICAL CORONARY VASODILATION .8. CLINICAL FEASIBILITY OF POSITRON CARDIAC IMAGING WITHOUT A CYCLOTRON USING GENERATOR-PRODUCED RB-82
    GOULD, KL
    GOLDSTEIN, RA
    MULLANI, NA
    KIRKEEIDE, RL
    WONG, WH
    TEWSON, TJ
    BERRIDGE, MS
    BOLOMEY, LA
    HARTZ, RK
    SMALLING, RW
    FUENTES, F
    NISHIKAWA, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) : 775 - 789
  • [10] HENZE E, 1983, J NUCL MED, V24, P987