DIFFERENTIAL PERMEATION OF HYDROGEN-SULFIDE THROUGH A MICROPOROUS VYCOR-TYPE GLASS MEMBRANE IN THE SEPARATION SYSTEM OF HYDROGEN AND HYDROGEN-SULFIDE

被引:15
作者
KAMEYAMA, T
DOKIYA, M
FUKUDA, K
KOTERA, Y
机构
[1] National Chemical Laboratory For Industry, Tsukuba Research Center, Yatabe
关键词
D O I
10.1080/01496397908058105
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The differential permeation of hydrogen sulfide through a microporous Vycor-type glass membrane was found in the hydrogen and hydrogen sulfide separation system. Separation factors of less than 1.0 were obtained at 10°C under higher pressures of a feed gas mixture having a low hydrogen concentration. © 1979, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:953 / 957
页数:5
相关论文
共 11 条
[1]   STUDY OF THERMOCHEMICAL HYDROGEN PREPARATION .4. APPLICATION OF EFFUSION ON THERMOCHEMICALLY LIMITED REACTION [J].
DOKIYA, M ;
KAMEYAMA, T ;
FUKUDA, K .
DENKI KAGAKU, 1977, 45 (11) :701-703
[2]   CATALYTIC DECOMPOSITION OF HYDROGEN-SULFIDE [J].
FUKUDA, K ;
DOKIYA, M ;
KAMEYAMA, T ;
KOTERA, Y .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1978, 17 (04) :243-248
[3]  
HAGERBAUMER DH, 1954, CHEM ENG PROG S SER, V50, P25
[4]  
Higashi K., 1964, J NUCL SCI TECHNOL, V1, P298, DOI DOI 10.1080/18811248.1964.9732128
[5]  
HUCKINS HE, 1953, CHEM ENG PROG, V49, P180
[6]  
Hwang S.T., 1966, SEPARATION SCI, V1, P629
[7]   SURFACE DIFFUSION IN MICROPOROUS MEDIA [J].
HWANG, ST ;
KAMMERMEYER, K .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1966, 44 (02) :82-+
[8]  
HWANG ST, 1975, MEMBRANES SEPARATION, P269
[9]   EFFECT OF ADSORPTION IN BARRIER SEPARATION [J].
KAMMERMEYER, K ;
WYRICK, DD .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1958, 50 (09) :1309-1310
[10]  
RAYMONT MED, 1975, HYDROCARB PROCESS, V54, P139