GLUCOSE POTENTIOMETRIC ELECTRODES BASED ON MEDIATORLESS BIOELECTROCATALYSIS - A NEW APPROACH

被引:23
|
作者
GHINDILIS, AL
KUROCHKIN, IN
机构
[1] Dept. of Biosensors, Research Centre for Molecular Diagnostics, 113149 Moscow
关键词
GLUCOSE; GLUCOSE OXIDASE; PEROXIDASE; BIOSENSOR;
D O I
10.1016/0956-5663(94)80035-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric method has been developed for analysis of glucose on the basis of glucose oxidase and peroxidase co-immobilized on the surface of an electrode made of composite carbonic material. Catalytic oxidation of glucose results in the formation of hydrogen peroxide. Mediatorless peroxidase catalysis of electroreduction of hydrogen peroxide leads to a shift in the electrode potential. The rate of the increase of the electrode potential is proportional to glucose concentration and calibration curve is linear at 0.025-2.0 mM. Electrodes permit at least 100 measurements without any loss in the activity. Electrodes remain stable for 90 days when stored at 277 K.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 50 条
  • [1] Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis
    Ghindilis, AL
    Morzunova, TG
    Barmin, AV
    Kurochkin, IN
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (09) : 873 - 880
  • [2] A LACCASE-GLUCOSE DEHYDROGENASE RECYCLING-ENZYME ELECTRODE BASED ON POTENTIOMETRIC MEDIATORLESS ELECTROCATALYTIC DETECTION
    GHINDILIS, AL
    MAKOWER, A
    SCHELLER, FW
    ANALYTICAL METHODS AND INSTRUMENTATION, 1995, 2 (03): : 129 - 132
  • [3] Potentiometric Biosensing of Glucose by Fullerene-Based Silver Selective Electrodes
    Kumar, Anish
    Patel, Bhargav
    Patel, Gaurang
    Menon, Shobhana K.
    FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2010, 18 (03) : 186 - 197
  • [4] AMPEROMETRIC BIOSENSORS BASED ON BIOCATALYST ELECTRODES. MEDIATED AND MEDIATORLESS ENZYME ELECTRODES
    Ikeda, Tokuji
    Miyaoka, Syuji
    Ozawa, Shyogo
    Matsushita, Fumio
    Kobayashi, Daisuke
    Senda, Mitsugi
    ANALYTICAL SCIENCES, 1991, 7 : 1443 - 1446
  • [5] Direct Electron Transfer-type Bioelectrocatalysis of Peroxidase at Mesoporous Carbon Electrodes and Its Application for Glucose Determination Based on Bienzyme System
    Hong-qi Xia
    Yuki Kitazumi
    Osamu Shirai
    Kenji Kano
    Analytical Sciences, 2017, 33 : 839 - 844
  • [6] Direct Electron Transfer-type Bioelectrocatalysis of Peroxidase at Mesoporous Carbon Electrodes and Its Application for Glucose Determination Based on Bienzyme System
    Xia, Hong-qi
    Kitazumi, Yuki
    Shirai, Osamu
    Kano, Kenji
    ANALYTICAL SCIENCES, 2017, 33 (07) : 839 - 844
  • [7] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    German, Natalija
    Ramanaviciene, Almira
    Voronovic, Jaroslav
    Ramanavicius, Arunas
    MICROCHIMICA ACTA, 2010, 168 (3-4) : 221 - 229
  • [8] STRIPPING MEASUREMENTS OF HYDROGEN-PEROXIDE BASED ON BIOCATALYTIC ACCUMULATION AT MEDIATORLESS PEROXIDASE CARBON PASTE ELECTRODES
    WANG, J
    CISZEWSKI, A
    NASER, N
    ELECTROANALYSIS, 1992, 4 (08) : 777 - 782
  • [9] Glucose monitoring by a biosensor based on mercury thin film electrodes
    Sezginturk, Mustafa Kemal
    Goktug, Tuge
    Dinckaya, Erhan
    ANALYTICAL LETTERS, 2008, 41 (06) : 1074 - 1082
  • [10] Potentiometric glucose biosensor based on a pH stainless steel electrode
    Cerón-Aparicio, R
    del Rosal-Vargas, JD
    Pérez-Saavedra, JJ
    Galán-Vidal, CA
    QUIMICA ANALITICA, 1999, 18 : 158 - 159