COMPARISON OF 8 MODIFICATIONS OF HEDLEY METHOD FOR FLOW CYTOMETRIC DNA PLOIDY ANALYSIS OF PARAFFIN-EMBEDDED TISSUE

被引:22
作者
SCHULTZ, DS
ZARBO, RJ
机构
[1] Department of Pathology, Henry Ford Hospital, Detroit, MI 48202
关键词
FLOW CYTOMETRY; HEDLEY METHOD; DNA PLOIDY; FLOW CYTOMETRY METHODS;
D O I
10.1093/ajcp/98.3.291
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Flow cytometric DNA analysis of nuclear suspensions from formalin-fixed, paraffin-embedded tissue often fails to detect aneuploid cell populations present in corresponding fresh tissue. Nuclear suspensions were prepared by 8 different modifications and standard Hedley's method using 50-mu-m sections of tissue blocks from 8 breast and 8 colonic carcinomas, all previously known to be DNA aneuploid by analysis of fresh tumor. Pepsin solutions of three different enzymatic activities were used to release nuclei using three different tissue digest formats. DNA aneuploidy was demonstrated overall in 7 of 72 different colon tumor experiments and 25 of 72 breast cancer experiments. Modifications yielded aneuploid populations not detected by the standard Hedley method; DNA aneuploidy of 4 breast and 2 colon cancers was detected by modifications compared to 2 breast and 1 colon cancer demonstrated by the standard. No single method consistently demonstrated DNA aneuploidy. High histogram baselines, presumably from debris, contributed to the marked loss of sensitivity in detecting most DNA aneuploid populations. Detection of DNA aneuploidy was most closely associated with specific cases, regardless of the method of nuclear suspension preparation. Recovery of DNA aneuploid nuclei seems to depend primarily on tissue processing or innate characteristics of the tumor cells, not on the method used to prepare the nuclear suspension.
引用
收藏
页码:291 / 295
页数:5
相关论文
共 17 条
  • [11] DIFFERENT OPINIONS ON CLASSIFICATION OF DNA HISTOGRAMS PRODUCED FROM PARAFFIN-EMBEDDED TISSUE
    JOENSUU, H
    KALLIONIEMI, OP
    [J]. CYTOMETRY, 1989, 10 (06): : 711 - 717
  • [12] EVIDENCE FOR FALSE ANEUPLOID PEAKS IN FLOW CYTOMETRIC ANALYSIS OF PARAFFIN-EMBEDDED TISSUE
    JOENSUU, H
    ALANEN, KA
    KLEMI, PJ
    AINE, R
    [J]. CYTOMETRY, 1990, 11 (03): : 431 - 437
  • [13] COMPARISON OF FRESH AND PARAFFIN-EMBEDDED TISSUE AS STARTING MATERIAL FOR DNA FLOW-CYTOMETRY AND EVALUATION OF INTRATUMOR HETEROGENEITY
    KALLIONIEMI, OP
    [J]. CYTOMETRY, 1988, 9 (02): : 164 - 169
  • [14] MODIFIED METHODOLOGY TO IMPROVE FLOW CYTOMETRIC DNA HISTOGRAMS FROM PARAFFIN-EMBEDDED MATERIAL
    MCLEMORE, DD
    ELNAGGAR, A
    STEPHENS, LC
    JARDINE, JH
    [J]. STAIN TECHNOLOGY, 1990, 65 (06): : 279 - 291
  • [15] REPRODUCIBILITY OF FCM DNA CONTENT FROM REPLICATE PARAFFIN BLOCK SAMPLES
    PRICE, J
    HERMAN, CJ
    [J]. CYTOMETRY, 1990, 11 (07): : 845 - 847
  • [16] FLOW CYTOMETRIC DETERMINATION OF DNA PLOIDY LEVEL IN NUCLEI ISOLATED FROM PARAFFIN-EMBEDDED TISSUE
    SCHUTTE, B
    REYNDERS, MMJ
    BOSMAN, FT
    BLIJHAM, GH
    [J]. CYTOMETRY, 1985, 6 (01): : 26 - 30
  • [17] EFFECT OF SECTION THICKNESS ON QUALITY OF FLOW CYTOMETRIC DNA CONTENT DETERMINATIONS IN PARAFFIN-EMBEDDED TISSUES
    STEPHENSON, RA
    GAY, H
    FAIR, WR
    MELAMED, MR
    [J]. CYTOMETRY, 1986, 7 (01): : 41 - 44