共 50 条
DETERMINATION OF BACLOFEN IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
被引:0
|作者:
TOSUNOGLU, S
ERSOY, L
机构:
来源:
关键词:
BACLOFEN DETERMINATION;
4-CHLORO-7-NITROBENZOFURAN;
HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY;
BIOLOGICAL FLUID;
D O I:
暂无
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
An isocratic reversed-phase column liquid chromatographic assay for baclofen was developed. Prior to analysis, derivatization of urine or deproteinized plasma with 4-chloro-7-nitrobenzofurazan (NBD-CI) reagent was employed. After solid-phase extraction on a small silica gel column, the mixture was chromatographed on a 10 mu m Bondapak C-18 column using methanol-water (45 + 55 v/v) as the mobile phase, The NBD-baclofen derivative was detected spectrofluorimetrically by monitoring the emission at 524 nm with excitation at 463 nm. The method was tested for suitability in routine analysis. After a single oral dose of 20 mg of baclofen, the plasma concentration and the cumulative urinary excretion of the drug were determined. The average recoveries were 99.5 and 98.5% for plasma and urine, respectively.
引用
收藏
页码:373 / 375
页数:3
相关论文