A 200 MM INPUT FIELD, 5-80 KEV DETECTOR BASED ON AN X-RAY IMAGE INTENSIFIER AND CCD CAMERA

被引:64
|
作者
MOY, JP
机构
[1] Detector Group, European Synchrotron Radiation Facility
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1994年 / 348卷 / 2-3期
关键词
D O I
10.1016/0168-9002(94)90815-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A special X-Ray Image Intensifier (XRII), derived from a medical device, has been developed for low energy X-ray detection. The performance of a complete detection system using this XRII optically coupled to a slow scan CCD camera is presented. DQE in excess of 50% between 6 and 25 ke V is obtained, together with an equivalent input dark signal of a few X-ray quanta per second per cm2; spatial resolution is 250 mum FWHM. One megapixel images with a 14 bit dynamic range are obtained in 5 s.
引用
收藏
页码:641 / 644
页数:4
相关论文
共 50 条
  • [41] Calibration and application of an X-ray image intensifier/charge-coupled device detector for monochromatic macromolecular crystallography
    Hammersley, AP
    Brown, K
    Burmeister, W
    Claustre, L
    Gonzalez, A
    McSweeney, S
    Mitchell, E
    Moy, JP
    Svensson, SO
    Thompson, AW
    JOURNAL OF SYNCHROTRON RADIATION, 1997, 4 : 67 - 77
  • [42] Technical Note: Correction of geometric x-ray image intensifier distortion based on digital image correlation
    Sanctorum, Joaquim
    Van Wassenbergh, Sam
    Aerts, Peter
    Dirckx, Joris
    MEDICAL PHYSICS, 2020, 47 (02) : 597 - 603
  • [43] Evaluation of an X-ray imaging detector based on a CMOS camera with logarithmic response
    Ponchut, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 457 (1-2): : 270 - 278
  • [44] Evaluation of a digital X-ray detector based on a phosphor-coated CCD for mammography
    Taibi, A.
    Del Guerra, A.
    Gambaccini, M.
    Marziani, M.
    Tuffanelli, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 392 (1-3): : 210 - 213
  • [45] Evaluation of a digital X-ray detector based on a phosphor-coated CCD for mammography
    Taibi, A
    DelGuerra, A
    Gambaccini, M
    Marziani, M
    Tuffanelli, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 210 - 213
  • [46] Development of large area CCD-based X-ray detector for macromolecular crystallography
    Pokric, M
    Allinson, NM
    Jorden, AR
    Cox, MP
    Marshall, A
    Long, PG
    Moon, K
    Jerram, P
    Pool, P
    Nave, C
    Derbyshire, GE
    Helliwell, JR
    DETECTORS FOR CRYSTALLOGRAPHY AND DIFFRACTION STUDIES AT SYNCHROTRON SOURCES, 1999, 3774 : 46 - 57
  • [47] A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system
    Gutierrez, Luis F.
    Ozturk, Cengizhan
    McVeigh, Elliot R.
    Lederman, Robert J.
    MEDICAL PHYSICS, 2008, 35 (03) : 997 - 1007
  • [48] Noise Analysis Technology for Visual System of X-ray Image Intensifier Based on Time Domain
    Wei, Li
    Qing, Hou
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 700 - 704
  • [49] QUANTITATIVE ASPECTS OF IMAGE INTENSIFIER-TELEVISION-BASED DIGITAL X-RAY IMAGING.
    Nalcioglu, O.
    Roeck, W.W.
    Seibert, J.A.
    Lando, A.V.
    Tobis, J.M.
    Henry, W.L.
    1986, : 83 - 132
  • [50] Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier
    Ducote, Justin L.
    Xu, Tong
    Molloi, Sabee
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 183 - 196