A 200 MM INPUT FIELD, 5-80 KEV DETECTOR BASED ON AN X-RAY IMAGE INTENSIFIER AND CCD CAMERA

被引:64
|
作者
MOY, JP
机构
[1] Detector Group, European Synchrotron Radiation Facility
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1994年 / 348卷 / 2-3期
关键词
D O I
10.1016/0168-9002(94)90815-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A special X-Ray Image Intensifier (XRII), derived from a medical device, has been developed for low energy X-ray detection. The performance of a complete detection system using this XRII optically coupled to a slow scan CCD camera is presented. DQE in excess of 50% between 6 and 25 ke V is obtained, together with an equivalent input dark signal of a few X-ray quanta per second per cm2; spatial resolution is 250 mum FWHM. One megapixel images with a 14 bit dynamic range are obtained in 5 s.
引用
收藏
页码:641 / 644
页数:4
相关论文
共 50 条
  • [11] X-RAY SPECTROMETER IN RANGE 5-200 KEV
    STRACHAN, JD
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (05): : 852 - 852
  • [12] A physical image quality evaluation of a CCD-based X-ray image intensifier digital fluorography system for cardiac applications
    Baker, EL
    Cowen, AR
    Kemner, R
    Bastiaens, R
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 430 - 441
  • [13] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [14] VERSATILE X-RAY SPECTROMETER IN RANGE 5-200 KEV
    STRACHAN, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (12): : 1542 - 1546
  • [15] CCD camera as feasible large-area-size x-ray detector for x-ray fluorescence spectroscopy and imaging
    Zhao, Wenyang
    Sakurai, Kenji
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (06):
  • [16] Soft X-ray spectrograph with CCD-Based detector
    Volkov, GS
    Zaitsev, VI
    AttelanLanglet, S
    Mishenskii, VO
    Papazyan, YV
    Fedulov, MV
    Smirnov, VP
    Etlicher, B
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1997, 40 (01) : 113 - 117
  • [17] X-ray imaging using CCD based area detector
    Sinha, A
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 71 - 74
  • [18] MTF OF A 210-70-MM FIBEROPTIC OUTPUT X-RAY IMAGE INTENSIFIER TUBE
    BATES, CW
    SPARKS, SD
    APPLIED OPTICS, 1975, 14 (07): : 1484 - 1485
  • [19] Image noise properties of a phosphor-coated CCD X-ray detector
    Gambaccini, M
    Taibi, A
    Baldelli, P
    Del Guerra, A
    Tuffanelli, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 508 - 510
  • [20] Image noise properties of a phosphor-coated CCD X-ray detector
    Gambaccini, M.
    Taibi, A.
    Baldelli, P.
    Del Guerra, A.
    Tuffanelli, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 409 (1-3): : 508 - 510