A 200 MM INPUT FIELD, 5-80 KEV DETECTOR BASED ON AN X-RAY IMAGE INTENSIFIER AND CCD CAMERA

被引:64
|
作者
MOY, JP
机构
[1] Detector Group, European Synchrotron Radiation Facility
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1994年 / 348卷 / 2-3期
关键词
D O I
10.1016/0168-9002(94)90815-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A special X-Ray Image Intensifier (XRII), derived from a medical device, has been developed for low energy X-ray detection. The performance of a complete detection system using this XRII optically coupled to a slow scan CCD camera is presented. DQE in excess of 50% between 6 and 25 ke V is obtained, together with an equivalent input dark signal of a few X-ray quanta per second per cm2; spatial resolution is 250 mum FWHM. One megapixel images with a 14 bit dynamic range are obtained in 5 s.
引用
收藏
页码:641 / 644
页数:4
相关论文
共 50 条
  • [1] The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detector
    Fujisawa, T
    Inoko, Y
    Yagi, N
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1106 - 1114
  • [2] 35 MM CINE CAMERA INCORPORATING A PHILIPS X-RAY IMAGE INTENSIFIER
    ARDRAN, GM
    WYATT, DG
    JOURNAL OF PHYSIOLOGY-LONDON, 1954, 126 (03): : P1 - P2
  • [3] PERFORMANCE OF A MEDICAL X-RAY IMAGE INTENSIFIER OPTICALLY COUPLED TO A COOLED CCD CAMERA
    MOY, JP
    MORSE, J
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 265 - 271
  • [4] INTRAORAL X-RAY FLUOROSCOPY WITH IMAGE INTENSIFIER AND CCD
    BOUCHIER, G
    LEDENMAT, D
    CAMUS, JP
    ROVILLE, JC
    MARTIN, G
    RICHARD, JC
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 558 - 558
  • [5] Studies of an X-ray imaging detector based on THGEM and CCD camera
    Peng, Zhi-Yuan
    Gu, Yung-Ting
    Xie, Yu-Guang
    Yan, Wen-Qi
    Zhao, Hang
    Li, Geng-Lan
    Jiang, Jie-Chen
    Feng, Huan-Bo
    Wang, Zhi-Gang
    Lv, Jun-Guang
    Hu, Tao
    Zhou, Li
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2018, 2 (01)
  • [6] HARD X-RAY-DETECTOR WITH AN MCP IMAGE INTENSIFIER WORKING IN THE 100 KEV 1 MEV X-RAY RANGE
    VEAUX, J
    CAVAILLER, C
    GEX, JP
    HAUDUCOEUR, A
    HYVERNAGE, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (06): : 1562 - 1567
  • [7] The solid-state x-ray image intensifier (SSXII): An EMCCD-Based x-ray detector
    Kuhls-Gilcrist, Andrew
    Yadava, Girijesh
    Patel, Vikas
    Jain, Amit
    Bednarek, Daniel R.
    Rudin, Stephen
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [8] Measurement of the effective size of the input phosphor of an x-ray image intensifier
    Feldman, A
    Cox, R
    Rosser, J
    MEDICAL PHYSICS, 1997, 24 (10) : 1641 - 1642
  • [9] X-RAY IMAGE INTENSIFIER WITH THIN METAL INPUT WINDOW.
    Sano, Testu
    Harao, Norio
    Denshi Tokyo/Electron Tokyo, 1980, (19): : 99 - 102
  • [10] Electric-field-induced structural changes measured with a CCD-coupled X-ray image intensifier
    van Reeuwijk, SJ
    Vonk, V
    Puig-Molina, A
    Graafsma, H
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2000, 33 : 1422 - 1429