Comparison of 21-gauge and 22-gauge Needles for Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration of Mediastinal and Hilar Lymph Nodes

被引:38
作者
Saji, Junko [1 ]
Kurimoto, Noriaki [2 ]
Morita, Katsuhiko [2 ]
Nakamura, Miho [1 ]
Inoue, Takeo [1 ]
Nakamura, Haruhiko [2 ]
Miyazawa, Teruomi [1 ]
机构
[1] St Marianna Univ, Sch Med, Div Resp & Infect Dis, Dept Internal Med, Kawasaki, Kanagawa, Japan
[2] St Marianna Univ, Sch Med, Div Chest Surg, Dept Surg, Kawasaki, Kanagawa, Japan
关键词
EBUS-TBNA; needle; diagnostic yield; lung cancer;
D O I
10.1097/LBR.0b013e3182273b41
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Although endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) using a 22-gauge needle has emerged as an accurate, minimally invasive, and safe technique for accessing undiagnosed mediastinal adenopathy, particularly in patients with lung cancer, the small sample size obtained by a conventional needle may limit the accuracy of the result. Objectives: We evaluated the safety and efficacy of obtaining specimens using 21-gauge needles, comparing diagnostic yield with conventional 22-gauge needles. Methods: Participants consisted of 56 consecutive patients with mediastinal lesions referred to our institution for diagnostic EBUS-TBNA. The 21-gauge needle group (21 G) included 24 patients with 6 nonmalignancies and the 22-gauge needle group (22G) included 32 patients with 9 nonmalignancies. Final diagnosis was based on cytology, histology, surgical results, appropriate clinical pictures on examination, and/or clinical follow-up. Results: Comparing 21G and 22G, inadequate material rates were 0% versus 3.1% in cytology, and 4.2% versus 18.8% in histology, respectively. Accuracy in cytology, histology, and combined cytology and/or histology were 91.7% versus 65.6% (P=0.02), 95.8% versus 81.3% (P=0.11), and 100% versus 84.4% (P=0.04), respectively. After limiting cases to suspected malignancies, sensitivity in cytology, histology, and combined cytology and/or histology were 88.9% versus 52.2% (P=0.01), 100% versus 82.6% (P=0.09), and 100% versus 87.0% (P=0.17), respectively. Conclusions: Increasing sample volume using a 21-gauge needle rather than a 22-gauge needle might improve diagnostic yield in EBUS-TBNA. This study revealed the benefits of using a 21-gauge needle for cytological and histologic diagnostic yields.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 18 条
  • [11] Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging
    Rintoul, RC
    Skwarski, KM
    Murchison, JT
    Wallace, WA
    Walker, WS
    Penman, ID
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (03) : 416 - 421
  • [12] COMPARISON OF THE WANG 19-GAUGE AND 22-GAUGE NEEDLES IN THE MEDIASTINAL STAGING OF LUNG-CANCER
    SCHENK, DA
    CHAMBERS, SL
    DERDAK, S
    KOMADINA, KH
    PICKARD, JS
    STROLLO, PJ
    LEWIS, RE
    PATEFIELD, AJ
    HENDERSON, JH
    TOMSKI, SM
    MORALES, CF
    STERLING, JL
    SOLANKI, PH
    MOORE, J
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (05): : 1251 - 1258
  • [13] Yield of transbronchial needle aspiration in diagnosis of mediastinal lesions
    Sharafkhaneh, A
    Baaklini, W
    Gorin, AB
    Green, L
    [J]. CHEST, 2003, 124 (06) : 2131 - 2135
  • [14] A Randomized Controlled Trial of Standard vs Endobronchial Ultrasonography-Guided Transbronchial Needle Aspiration in Patients With Suspected Sarcoidosis
    Tremblay, Alain
    Stather, David R.
    MacEachern, Paul
    Khalil, Moosa
    Field, Stephen K.
    [J]. CHEST, 2009, 136 (02) : 340 - 346
  • [15] FLEXIBLE TRANS-BRONCHIAL NEEDLE ASPIRATION FOR STAGING OF BRONCHOGENIC-CARCINOMA
    WANG, KP
    BROWER, R
    HAPONIK, EF
    SIEGELMAN, S
    [J]. CHEST, 1983, 84 (05) : 571 - 576
  • [16] TRANS-BRONCHIAL NEEDLE ASPIRATION FOR DIAGNOSIS OF LUNG-CANCER
    WANG, KP
    MARSH, BR
    SUMMER, WR
    TERRY, PB
    EROZAN, YS
    BAKER, RR
    [J]. CHEST, 1981, 80 (01) : 48 - 50
  • [17] Endobronchial ultrasound: new insight for the diagnosis of sarcoidosis
    Wong, M.
    Yasufuku, K.
    Nakajima, T.
    Herth, F. J. F.
    Sekine, Y.
    Shibuya, K.
    Iizasa, T.
    Hiroshima, K.
    Lam, W. K.
    Fujisawa, T.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2007, 29 (06) : 1182 - 1186
  • [18] Real-time endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes
    Yasufuku, K
    Chiyo, M
    Sekine, Y
    Chhajed, PN
    Shibuya, K
    Iizasa, T
    Fujisawa, T
    [J]. CHEST, 2004, 126 (01) : 122 - 128