Comparison of 21-gauge and 22-gauge Needles for Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration of Mediastinal and Hilar Lymph Nodes

被引:38
作者
Saji, Junko [1 ]
Kurimoto, Noriaki [2 ]
Morita, Katsuhiko [2 ]
Nakamura, Miho [1 ]
Inoue, Takeo [1 ]
Nakamura, Haruhiko [2 ]
Miyazawa, Teruomi [1 ]
机构
[1] St Marianna Univ, Sch Med, Div Resp & Infect Dis, Dept Internal Med, Kawasaki, Kanagawa, Japan
[2] St Marianna Univ, Sch Med, Div Chest Surg, Dept Surg, Kawasaki, Kanagawa, Japan
关键词
EBUS-TBNA; needle; diagnostic yield; lung cancer;
D O I
10.1097/LBR.0b013e3182273b41
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Although endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) using a 22-gauge needle has emerged as an accurate, minimally invasive, and safe technique for accessing undiagnosed mediastinal adenopathy, particularly in patients with lung cancer, the small sample size obtained by a conventional needle may limit the accuracy of the result. Objectives: We evaluated the safety and efficacy of obtaining specimens using 21-gauge needles, comparing diagnostic yield with conventional 22-gauge needles. Methods: Participants consisted of 56 consecutive patients with mediastinal lesions referred to our institution for diagnostic EBUS-TBNA. The 21-gauge needle group (21 G) included 24 patients with 6 nonmalignancies and the 22-gauge needle group (22G) included 32 patients with 9 nonmalignancies. Final diagnosis was based on cytology, histology, surgical results, appropriate clinical pictures on examination, and/or clinical follow-up. Results: Comparing 21G and 22G, inadequate material rates were 0% versus 3.1% in cytology, and 4.2% versus 18.8% in histology, respectively. Accuracy in cytology, histology, and combined cytology and/or histology were 91.7% versus 65.6% (P=0.02), 95.8% versus 81.3% (P=0.11), and 100% versus 84.4% (P=0.04), respectively. After limiting cases to suspected malignancies, sensitivity in cytology, histology, and combined cytology and/or histology were 88.9% versus 52.2% (P=0.01), 100% versus 82.6% (P=0.09), and 100% versus 87.0% (P=0.17), respectively. Conclusions: Increasing sample volume using a 21-gauge needle rather than a 22-gauge needle might improve diagnostic yield in EBUS-TBNA. This study revealed the benefits of using a 21-gauge needle for cytological and histologic diagnostic yields.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 18 条
  • [1] RAPID ON-SITE EVALUATION OF TRANSBRONCHIAL ASPIRATES
    DAVENPORT, RD
    [J]. CHEST, 1990, 98 (01) : 59 - 61
  • [2] The utility of transbronchial needle aspiration in the staging of bronchogenic carcinoma
    Harrow, EM
    Abi-Saleh, W
    Blum, J
    Harkin, T
    Gasparini, S
    Addrizzo-Harris, DJ
    Arroliga, AC
    Wight, G
    Mehta, AC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (02) : 601 - 607
  • [3] FINE NEEDLE ASPIRATION CYTOLOGY - AN INVITRO STUDY OF CELL YIELD
    HARTLEY, MN
    TUFFNELL, DJ
    HUTTON, JL
    PALMER, M
    ALJAFARI, MS
    [J]. BRITISH JOURNAL OF SURGERY, 1988, 75 (04) : 380 - 381
  • [4] Real-time endobronchial ultrasound guided transbronchial needle aspiration for sampling mediastinal lymph nodes
    Herth, F. J. F.
    Eberhardt, R.
    Vilmann, P.
    Krasnik, M.
    Ernst, A.
    [J]. THORAX, 2006, 61 (09) : 795 - 798
  • [5] Actual role of endobronchial ultrasound (EBUS)
    Herth, Felix J. F.
    Eberhardt, R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (07) : 1806 - 1812
  • [6] Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis
    Holty, JEC
    Kuschner, WG
    Gould, MK
    [J]. THORAX, 2005, 60 (11) : 949 - 955
  • [7] ENDOBRONCHIAL SONOGRAPHY - FEASIBILITY AND PRELIMINARY-RESULTS
    HURTER, T
    HANRATH, P
    [J]. THORAX, 1992, 47 (07) : 565 - 567
  • [8] SAMPLE-SIZE IN FINE NEEDLE ASPIRATION BIOPSY
    KREULA, J
    BONDESTAM, S
    VIRKKUNEN, P
    [J]. BRITISH JOURNAL OF SURGERY, 1989, 76 (12) : 1270 - 1272
  • [9] Targeting Area in Metastatic Lymph Nodes in Lung Cancer for Endobronchial Ultrasonography-guided Transbronchial Needle Aspiration
    Kurimoto, Noriaki
    Osada, Hiroaki
    Miyazawa, Teruomi
    Nishisaka, Takashi
    Murayama, Masaki
    [J]. JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2008, 15 (03) : 134 - 138
  • [10] Comparison of 21-gauge and 22-gauge aspiration needle during endobronchial ultrasound-guided transbronchial needle aspiration
    Nakajima, Takahiro
    Yasufuku, Kazuhiro
    Takahashi, Ryo
    Shingyoji, Masato
    Hirata, Tetsushi
    Itami, Makiko
    Matsui, Yukiko
    Itakura, Meiji
    Iizasa, Toshihiko
    Kimura, Hideki
    [J]. RESPIROLOGY, 2011, 16 (01) : 90 - 94