A SIMPLIFIED PROXIMAL ISOVELOCITY SURFACE-AREA APPROACH FOR ESTIMATING SEVERITY OF MITRAL REGURGITATION - MEASUREMENT OF PISA RADIUS VERSUS ISOVELOCITY

被引:0
|
作者
YAMACHIKA, S [1 ]
REID, CL [1 ]
GARDIN, JM [1 ]
机构
[1] UNIV CALIF IRVINE,IRVINE,CA 92717
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:109 / 109
页数:1
相关论文
共 50 条
  • [21] A simple different method to use proximal isovelocity surface area (PISA) for measuring mitral valve area
    Uzun, M
    Baysan, O
    Erinc, K
    Ozkan, M
    Sag, C
    Genc, C
    Karaeren, H
    Yokusoglu, M
    Isik, E
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (06): : 633 - 640
  • [22] SIMPLIFIED FORMULA FOR ESTIMATING REGURGITANT FRACTION BY THE COLOR DOPPLER PROXIMAL ISOVELOCITY SURFACE-AREA METHOD - INVITRO VALIDATION
    YAMACHIKA, S
    UTSUNOMIYA, T
    SAVANI, D
    TALATI, R
    DESAI, J
    SUTHER, M
    GARDIN, JM
    CLINICAL RESEARCH, 1992, 40 (01): : A121 - A121
  • [23] A simple different method to use proximal isovelocity surface area (PISA) for measuring mitral valve area
    Uzun, M.
    Baysan, O.
    Erinc, S. K.
    Sag, C.
    Yokusoglu, M.
    Ozkan, M.
    Genc, C.
    Isik, E.
    EUROPEAN HEART JOURNAL, 2005, 26 : 690 - 690
  • [24] CAN PROXIMAL ISOVELOCITY SURFACE-AREA METHOD CALCULATE STENOTIC MITRAL-VALVE AREA IN PATIENTS WITH ASSOCIATED AORTIC REGURGITATION
    IKAWA, H
    HABU, H
    HIRANO, Y
    NAITOU, T
    SASAKI, T
    KATORI, R
    CIRCULATION, 1993, 88 (04) : 450 - 450
  • [25] CARDIAC MOTION CAN ALTER PROXIMAL ISOVELOCITY SURFACE-AREA (PISA) CALCULATIONS OF REGURGITANT FLOW
    CAPE, EG
    YOGANATHAN, AP
    MURALIDHARAN, E
    HEINRICH, R
    LEVINE, RA
    CIRCULATION, 1992, 86 (04) : 258 - 258
  • [26] Simple method for estimating regurgitant volume with use of a single radius for measuring proximal isovelocity surface area: An in vitro study of simulated mitral regurgitation
    Tokushima, T
    Reid, CL
    Hata, A
    Gardin, JM
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (02) : 104 - 113
  • [27] Quantification of Mitral Valve Regurgitation in Cavalier King Charles Spaniels and Chihuahuas Using Radius of Proximal Isovelocity Surface Area
    Koch, Jorgen
    Engeland, Inge V.
    Willesen, Jakob L.
    Schroder, Anders S.
    Gleerup, Caroline H.
    Bach, Maiken B. T.
    ANIMALS, 2024, 14 (19):
  • [28] CON: Proximal isovelocity surface area should not be measured routinely in all patients with mitral regurgitation
    Savage, Robert M.
    Konstadt, Steven
    ANESTHESIA AND ANALGESIA, 2007, 105 (04): : 944 - 946
  • [29] True shape and area of proximal isovelocity surface area (PISA) when flow convergence is hemispherical in valvular regurgitation
    Francis, DP
    Willson, K
    Davies, LC
    Florea, VG
    Coats, AJS
    Gibson, DG
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2000, 73 (03) : 237 - 242
  • [30] Proximal isovelocity surface area should be routinely measured in evaluating mitral regurgitation: A core review
    Lambert, A. Stephane
    ANESTHESIA AND ANALGESIA, 2007, 105 (04): : 940 - 943