INFLUENCE OF CARDIAC MOTION ON DOPPLER MEASUREMENTS USING IN-VITRO AND IN-VIVO MODELS

被引:15
作者
CAO, T
SHAPIRO, SM
BERSOHN, MM
LIU, SCK
GINZTON, LE
机构
[1] UNIV CALIF LOS ANGELES,LOS ANGELES CTY HARBOR MED CTR,DEPT MED,DIV CARDIOL,BLDG RB-2,TORRANCE,CA 90509
[2] VET AFFAIRS MED CTR,LOS ANGELES,CA
[3] UNIV CALIF LOS ANGELES,SCH MED,LOS ANGELES,CA 90024
[4] FOURTH MIL MED UNIV,SECOND TEACHING HOSP,XIAN,PEOPLES R CHINA
关键词
D O I
10.1016/0735-1097(93)90843-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Using both in vitro and in vivo techniques, we investigated the extent to which cardiac motion alters Doppler-measured blood flow velocity and thus potentially can alter the calculation of valve areas or pressure gradients. Background. Blood flow velocity measured by Doppler ultrasound represents the net motion of the blood relative to the transducer. It is widely assumed that the measured velocity represents the actual flow. It has been demonstrated that cardiac motion generates regularly occurring low velocity Doppler signals that are commonly treated as artifact. Methods. We used an in vitro model that allowed us to measure and independently control the flow of a liquid through a chamber and the motion of the chamber relative to the Doppler beam. A cornstarch-water slurry was driven by a pulsatile pump through tubing to simulate the blood flow within the heart, and the tubing was cyclically moved by a piston to simulate the heart motion. We also measured cardiac motion using M-mode and two-dimensional echocardiography and compared the results with the Doppler signal derived from cardiac motion in subjects without cardiac disease. Results. In the in vitro model, alteration in the motion of the tubing resulted in apparent changes in the measured maximal velocity of the fluid. The Doppler spectrum of the combined motion of the tubing and the fluid was the algebraic sum of their Doppler signals. In human subjects, the maximal slope of the M-mode tracing of the aortic annular motion and the peak Doppler signal due to cardiac motion were compared and were highly correlated. Conclusions. Cardiac motion alters the Doppler signal derived from blood flow. This effect can be demonstrated in vitro and in vivo.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 12 条
  • [1] Cao T, 1991, CHIN J ULTRASOUND ME, V7, P84
  • [2] Movements of the base of the ventricle and the relative constancy of the cardiac volume
    Hamilton, WF
    Rompf, JH
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1932, 102 (03): : 559 - 565
  • [3] Hammarstrom E, 1991, J Am Soc Echocardiogr, V4, P131
  • [4] DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF LOW VELOCITY MOTION OF THE LEFT-VENTRICULAR POSTERIOR WALL
    ISAAZ, K
    THOMPSON, A
    ETHEVENOT, G
    CLOEZ, JL
    BREMBILLA, B
    PERNOT, C
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (01) : 66 - 75
  • [5] ISAAZ K, 1989, CIRCULATION S2, V80, P169
  • [6] JONES CJH, 1991, BRIT HEART J, V65, P31
  • [7] MITRAL ANULUS MOTION - RELATION TO PULMONARY VENOUS AND TRANSMITRAL FLOWS IN NORMAL SUBJECTS AND IN PATIENTS WITH DILATED CARDIOMYOPATHY
    KEREN, G
    SONNENBLICK, EH
    LEJEMTEL, TH
    [J]. CIRCULATION, 1988, 78 (03) : 621 - 629
  • [8] PULMONARY VENOUS FLOW PATTERN - ITS RELATIONSHIP TO CARDIAC DYNAMICS - A PULSED DOPPLER ECHOCARDIOGRAPHIC STUDY
    KEREN, G
    SHEREZ, J
    MEGIDISH, R
    LEVITT, B
    LANIADO, S
    [J]. CIRCULATION, 1985, 71 (06) : 1105 - 1112
  • [9] SIZE AND MOTION OF THE MITRAL-VALVE ANNULUS IN MAN .1. A TWO-DIMENSIONAL ECHOCARDIOGRAPHIC METHOD AND FINDINGS IN NORMAL SUBJECTS
    ORMISTON, JA
    SHAH, PM
    TEI, C
    WONG, M
    [J]. CIRCULATION, 1981, 64 (01) : 113 - 120
  • [10] SHAPIRO SM, 1991, J AM COLL CARDIOL, V17, P1145