MEASUREMENT OF INTRACELLULAR PH USING FLOW-CYTOMETRY WITH CARBOXY-SNARF-1

被引:61
|
作者
WIEDER, ED [1 ]
HANG, HY [1 ]
FOX, MH [1 ]
机构
[1] COLORADO STATE UNIV,DEPT RADIOL HLTH SCI,FT COLLINS,CO 80523
来源
CYTOMETRY | 1993年 / 14卷 / 08期
关键词
DICYANOHYDROQUINONE; SNARF-1; FLOW CYTOMETRY; INTRACELLULAR PH;
D O I
10.1002/cyto.990140810
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The new intracellular pH (pH(i)) dye carboxy-seminaphthorhodafluor (SNARF-1) was compared to the established dye 2,3-dicyanohydroquinone (DCH) using flow cytometry. Both dyes give high-resolution pH(i) measurements. SNARF-1 remains trapped within cells much longer than DCH, so that pH(i) can be monitored during and after treatments with chemicals or hyperthermia. The toxicity of the dyes is similar, and both dyes can be used at concentrations that result in low toxicity to cells. Adequate staining of cells with SNARF-1 is dependent on the cell concentration. The absolute pH(i) values indicated by SNARF-1 are higher than values measured with DCH. However, the trends measured by both dyes are consistent, and both are useful for making pH(i) measurements. (C) 1993 Wiley-Liss, Inc.
引用
收藏
页码:916 / 921
页数:6
相关论文
共 50 条
  • [1] RATIOMETRIC MEASUREMENT OF INTRACELLULAR PH IN CULTURED HUMAN KERATINOCYTES USING CARBOXY-SNARF-1 AND FLOW-CYTOMETRY
    VANERP, PEJ
    JANSEN, MJJM
    DEJONGH, GJ
    BOEZEMAN, JBM
    SCHALKWIJK, J
    CYTOMETRY, 1991, 12 (02): : 127 - 132
  • [2] APPLICATION OF A NEW PH-SENSITIVE FLUOROPROBE (CARBOXY-SNARF-1) FOR INTRACELLULAR PH MEASUREMENT IN SMALL, ISOLATED CELLS
    BUCKLER, KJ
    VAUGHANJONES, RD
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1990, 417 (02): : 234 - 239
  • [3] Detection of apoptosis by flow cytometry of cells simultaneously stained for intracellular pH (Carboxy SNARF-1) and membrane permeability (Hoechst 33342)
    Reynolds, JE
    Li, JF
    Eastman, A
    CYTOMETRY, 1996, 25 (04): : 349 - 357
  • [4] Use of flow cytometry and SNARF to calibrate and measure intracellular pH in NSO cells
    Bond, J
    Varley, J
    CYTOMETRY PART A, 2005, 64A (01) : 43 - 50
  • [5] THE MEASUREMENT OF INTRACELLULAR ANTIGENS AND DNA BY MULTIPARAMETRIC FLOW-CYTOMETRY
    CAMPLEJOHN, RS
    JOURNAL OF MICROSCOPY-OXFORD, 1994, 176 : 1 - 7
  • [6] Flow cytometry for the intracellular pH measurement of glutamate producing Corynebacterium glutamicum
    Leyval, D
    Debay, F
    Engasser, JM
    Goergen, JL
    JOURNAL OF MICROBIOLOGICAL METHODS, 1997, 29 (02) : 121 - 127
  • [7] DETECTION OF INTRACELLULAR CYTOKINES BY FLOW-CYTOMETRY
    JUNG, T
    SCHAUER, U
    HEUSSER, C
    NEUMANN, C
    RIEGER, C
    JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 159 (1-2) : 197 - 207
  • [8] MEASUREMENT OF ALLOANTIBODY BY FLOW-CYTOMETRY
    LEENAERTS, PL
    DERUYSSCHER, D
    VANDEPUTTE, M
    WAER, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 130 (01) : 73 - 79
  • [9] Measurement of intracellular pH in cultured cells by flow cytometry with BCECF-AM
    Franck, P
    Petitipain, N
    Cherlet, M
    Dardennes, M
    Maachi, F
    Schutz, B
    Poisson, L
    Nabet, P
    JOURNAL OF BIOTECHNOLOGY, 1996, 46 (03) : 187 - 195
  • [10] SIMULTANEOUS MEASUREMENT OF CELL-SURFACE AND INTRACELLULAR ANTIGENS BY MULTIPLE FLOW-CYTOMETRY
    SUMNER, H
    ABRAHAM, D
    BOUGHARIOS, G
    PLATERZYBERK, C
    OLSEN, I
    JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 136 (02) : 259 - 267