Simplified protocol for flow cytometry analysis of fluorescently labeled exosomes and microvesicles using dedicated flow cytometer

被引:297
作者
Pospichalova, Vendula [1 ]
Svoboda, Jan [2 ,3 ]
Dave, Zankruti [1 ]
Kotrbova, Anna [1 ]
Kaiser, Karol [1 ]
Klemova, Dobromila [4 ]
Ilkovics, Ladislav [4 ]
Hampl, Ales [4 ]
Crha, Igor [5 ]
Jandakova, Eva [6 ,7 ]
Minar, Lubos [5 ]
Weinberger, Vit [5 ]
Bryja, Vitezslav [1 ,8 ]
机构
[1] Masaryk Univ, Fac Sci, CZ-62500 Brno, Czech Republic
[2] Acad Sci Czech Republ, Inst Microbiol, Cytometry & Microscopy Facil, Prague, Czech Republic
[3] Bioport Europe, Svinare, Czech Republic
[4] Masaryk Univ, Fac Med, CZ-62500 Brno, Czech Republic
[5] Fac Hosp Brno, Dept Obstet & Gynecol, Brno, Czech Republic
[6] Masaryk Univ, Dept Pathol, CZ-62500 Brno, Czech Republic
[7] Univ Hosp Brno, Brno, Czech Republic
[8] Acad Sci Czech Republ, Inst Biophys, CS-61265 Brno, Czech Republic
关键词
exosomes; microvesicles; extracellular vesicles; quantification; flow cytometry; fluorescent labeling; CFSE; lipophilic styryl dye; ascites;
D O I
10.3402/jev.v4.25530
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Flow cytometry is a powerful method, which is widely used for high-throughput quantitative and qualitative analysis of cells. However, its straightforward applicability for extracellular vesicles (EVs) and mainly exosomes is hampered by several challenges, reflecting mostly the small size of these vesicles (exosomes: similar to 80-200 nm, microvesicles: similar to 200-1,000 nm), their polydispersity, and low refractive index. The current best and most widely used protocol for beads-free flow cytometry of exosomes uses ultracentrifugation (UC) coupled with floatation in sucrose gradient for their isolation, labeling with lipophilic dye PKH67 and antibodies, and an optimized version of commercial high-end cytometer for analysis. However, this approach requires an experienced flow cytometer operator capable of manual hardware adjustments and calibration of the cytometer. Here, we provide a novel and fast approach for quantification and characterization of both exosomes and microvesicles isolated from cell culture media as well as from more complex human samples (ascites of ovarian cancer patients) suitable for multiuser labs by using a flow cytometer especially designed for small particles, which can be used without adjustments prior to data acquisition. EVs can be fluorescently labeled with protein-(Carboxyfluoresceinsuccinimidyl ester, CFSE) and/or lipid- (FM) specific dyes, without the necessity of removing the unbound fluorescent dye by UC, which further facilitates and speeds up the characterization of microvesicles and exosomes using flow cytometry. In addition, double labeling with protein-and lipid-specific dyes enables separation of EVs from common contaminants of EV preparations, such as protein aggregates or micelles formed by unbound lipophilic styryl dyes, thus not leading to overestimation of EV numbers. Moreover, our protocol is compatible with antibody labeling using fluorescently conjugated primary antibodies. The presented methodology opens the possibility for routine quantification and characterization of EVs from various sources. Finally, it has the potential to bring a desired level of control into routine experiments and non-specialized labs, thanks to its simple bead-based standardization.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 32 条
[1]   Exosomes and communication between tumours and the immune system: are all exosomes equal? [J].
Bobrie, Angelique ;
Thery, Clotilde .
BIOCHEMICAL SOCIETY TRANSACTIONS, 2013, 41 :263-267
[2]  
Bohren C. F., 2004, ABSORPTION SCATTERIN, DOI [10.1002/9783527618156, DOI 10.1002/9783527618156]
[3]   Wnt-3a utilizes a novel low dose and rapidly pathway that does not require casein kinase 1-mediated phosphorylation of Dvl to activate β-catenin [J].
Bryja, Vitezslav ;
Schulte, Gunnar ;
Arenas, Ernest .
CELLULAR SIGNALLING, 2007, 19 (03) :610-616
[4]   A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometer [J].
Chandler, W. L. ;
Yeung, W. ;
Tait, J. F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (06) :1216-1224
[5]   Sizing and phenotyping of cellular vesicles using Nanoparticle Tracking Analysis [J].
Dragovic, Rebecca A. ;
Gardiner, Christopher ;
Brooks, Alexandra S. ;
Tannetta, Dionne S. ;
Ferguson, David J. P. ;
Hole, Patrick ;
Carr, Bob ;
Redman, Christopher W. G. ;
Harris, Adrian L. ;
Dobson, Peter J. ;
Harrison, Paul ;
Sargent, Ian L. .
NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2011, 7 (06) :780-788
[6]   Extracellular vesicle sizing and enumeration by nanoparticle tracking analysis [J].
Gardiner, Chris ;
Ferreira, Yannick J. ;
Dragovic, Rebecca A. ;
Redman, Christopher W. G. ;
Sargent, Ian L. .
JOURNAL OF EXTRACELLULAR VESICLES, 2013, 2 (01)
[7]   Syntenin-ALIX exosome biogenesis and budding into multivesicular bodies are controlled by ARF6 and PLD2 [J].
Ghossoub, Rania ;
Lembo, Frederique ;
Rubio, Aude ;
Gaillard, Carole Baron ;
Bouchet, Jerome ;
Vitale, Nicolas ;
Slavik, Josef ;
Machala, Miroslav ;
Zimmermann, Pascale .
NATURE COMMUNICATIONS, 2014, 5
[8]   A comprehensive overview of exosomes as drug delivery vehicles - Endogenous nanocarriers for targeted cancer therapy [J].
Johnsen, Kasper Bendix ;
Gudbergsson, Johann Mar ;
Skov, Martin Najbjerg ;
Pilgaard, Linda ;
Moos, Torben ;
Duroux, Meg .
BIOCHIMICA ET BIOPHYSICA ACTA-REVIEWS ON CANCER, 2014, 1846 (01) :75-87
[9]   Meeting the challenge of ascites in ovarian cancer: new avenues for therapy and research [J].
Kipps, Emma ;
Tan, David S. P. ;
Kaye, Stan B. .
NATURE REVIEWS CANCER, 2013, 13 (04) :273-282
[10]   Standardization of platelet-derived microparticle enumeration by flow cytometry with calibrated beads: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshop [J].
Lacroix, R. ;
Robert, S. ;
Poncelet, P. ;
Kasthuri, R. S. ;
Key, N. S. ;
Dignat-George, F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (11) :2571-2574