DIRECT GAS-CHROMATOGRAPHIC DETERMINATION OF CARBAMATE PESTICIDES USING CARBOWAX 20M-MODIFIED SUPPORTS AND THE ELECTROLYTIC CONDUCTIVITY DETECTOR

被引:42
作者
HALL, RC [1 ]
HARRIS, DE [1 ]
机构
[1] US EPA,DIV ENVIRONM TOXICOL,HLTH EFFECTS RES LAB,RES TRIANGLE PK,NC 27711
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 169卷 / FEB期
关键词
D O I
10.1016/0021-9673(75)85048-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The gas chromatographic behavior of 32 carbamate pesticides was investigated using the Hall electrolytic conductivity detector. Relative retention indices were successfully determined for 24 carbamates on six different columns. Columns investigated included Ultra-Bond, 3% OV-101 on Ultra-Bond, 1% OV-17 on Ultra-Bond, 1 % OV-210 an Ultra Bond, 1 % Carbowax 20M on Ultra-Bond and 0.5 % OV-210 + 0.65% OV-17 on Ultra-Bond. Chemical-ionization gas chromatography-mass spectrometry was used to verify that the carbamates were chromatographed intact. Chemical-ionization mass spectra are reported. Analytical procedures are demonstrated for the determination of carbamate residue in soil. © 1979.