HUMAN CORONARY-ARTERIES - PROJECTION ANGIOGRAMS RECONSTRUCTED FROM BREATH-HOLD 2-DIMENSIONAL MR IMAGES

被引:46
作者
EDELMAN, RR
MANNING, WJ
PEARLMAN, J
LI, W
机构
[1] BETH ISRAEL HOSP,CHARLES A DANA RES INST,DEPT MED,DIV CARDIOVASC,BOSTON,MA 02215
[2] HARVARD UNIV,BETH ISRAEL HOSP,THORNDIKE LAB,BOSTON,MA 02215
[3] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
CORONARY VESSELS; STENOSIS OR OBSTRUCTION;
D O I
10.1148/radiology.187.3.8497620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors sought to render projection magnetic resonance (MR) angiograms depicting a substantial length of human coronary arteries from sequential breath-hold two-dimensional MR images. Tomographic images of the right and left anterior descending coronary arteries were collected with use of a segmented gradient-recalled sequence that incorporated fat suppression and prone positioning of the patient over a surface coil. After editing the images to eliminate overlapping chamber signals and after realigning the images, a maximum-intensity-projection algorithm was applied to create projection angiograms. For the 10 coronary arteries without severe narrowing, visualized length with projection MR angiography was 109 mm +/- 29 (mean +/- standard error of estimate) versus 121 mm +/- 29 with conventional coronary angiography (ranges, 62-147 mm and 70-180 mm, respectively). At conventional angiography linear regression indicated vessel length to be 1.03 times the length depicted at MR angiography with good correlation (r = .8). Results indicate good correlation between measurements of vessel length with both conventional and MR angiography.
引用
收藏
页码:719 / 722
页数:4
相关论文
共 9 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING
    CHO, ZH
    MUN, CW
    FRIEDENBERG, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) : 134 - 143
  • [3] CONGENITAL HEART-DISEASE - GATED MR IMAGING IN 72 PATIENTS
    DIDIER, D
    HIGGINS, CB
    FISHER, MR
    OSAKI, L
    SILVERMAN, NH
    CHEITLIN, MD
    [J]. RADIOLOGY, 1986, 158 (01) : 227 - 235
  • [4] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [5] FUNCTIONAL-EVALUATION OF THE HEART WITH MAGNETIC-RESONANCE IMAGING
    HIGGINS, CB
    HOLT, W
    PFLUGFELDER, P
    SECHTEM, U
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) : 121 - 139
  • [6] MAGNETIC-RESONANCE-IMAGING - A RELIABLE TEST FOR THE EVALUATION OF PROXIMAL ATHEROSCLEROTIC RENAL ARTERIAL-STENOSIS
    KENT, KC
    EDELMAN, RR
    KIM, DS
    STEINMAN, TI
    PORTER, DH
    SKILLMAN, JJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1991, 13 (02) : 311 - 318
  • [7] MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING
    LAUB, GA
    KAISER, WA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) : 377 - 382
  • [8] 3-DIMENSIONAL (VOLUME) GRADIENT-ECHO IMAGING OF THE CAROTID BIFURCATION - PRELIMINARY CLINICAL-EXPERIENCE
    MASARYK, TJ
    MODIC, MT
    RUGGIERI, PM
    ROSS, JS
    LAUB, G
    LENZ, GW
    TKACH, JA
    HAACKE, EM
    SELMAN, WR
    HARIK, SI
    [J]. RADIOLOGY, 1989, 171 (03) : 801 - 806
  • [9] INTRACRANIAL CIRCULATION - PULSE-SEQUENCE CONSIDERATIONS IN 3-DIMENSIONAL (VOLUME) MR ANGIOGRAPHY
    RUGGIERI, PM
    LAUB, GA
    MASARYK, TJ
    MODIC, MT
    [J]. RADIOLOGY, 1989, 171 (03) : 785 - 791