THE COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT BY GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR PUFF TONOMETER: A CROSS-SECTIONAL RESEARCH

被引:0
|
作者
Arooj, Bushra [1 ]
Nadeem, Asmarah [1 ]
Ali, Sobia [1 ]
机构
[1] Lahore Gen Hosp, Lahore, Pakistan
来源
INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES | 2018年 / 5卷 / 12期
关键词
Tonometry; Glaucoma; Goldmann Applanation Tonometer and Air Puff Tonometer;
D O I
10.5281/zenodo.2526307
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Objective: The aim of this particular research was to determine the accuracy and frequency of intraocular pressure which measured with the help of an Air Puff (non-contact tonometer); moreover, we also confirmed the same by Goldmann applanation tonometer. Material and methods: Our research design was cross-sectional and it was carried out at Ophthalmology Department of Mayo Hospital, Lahore (February to July 2017) on a total of 240 patients. All the patients were in the age bracket of (10 - 70) years including males and females. The selection process included those patients who visited Eye OPD for regular intraocular pressure, refraction, glaucoma, cataract surgery and suspected glaucoma. A complete ocular assessment was mandatory for every individual participating in the research. Results: In the age bracket of (10 - 70) years the mean age was (43.844 +/- 15.434) years and the values of mean IOP was for Goldmann Applanation Tonometer as (18.92 +/- 8.852) mmHg and for Air Puff Tonometer as (21.463 +/- 9.456) mmHg. The different measurement ranges for Air-Puff Tonometer and Goldmann Applanation Tonometer was respectively (10 - 54) mmHg and (11 - 58) mmHg. Conclusion: In order to measure intraocular pressure, the method of Air puff tonometer is non-contact and quick. Air Puff tonometer is effective for screening purposes; whereas, the intraocular pressure measurements are accurately measured through Goldmann applanation tonometer.
引用
收藏
页码:16875 / 16879
页数:5
相关论文
共 50 条
  • [21] Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    Annette Lösch
    Alexander Scheuerle
    Volker Rupp
    Gerd Auffarth
    Matthias Becker
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 313 - 316
  • [22] THE KEELER PULSAIR AIR IMPULSE TONOMETER - COMPARISON WITH THE PERKINS HAND-HELD APPLANATION TONOMETER FOR PERI-OPERATIVE MEASUREMENT OF INTRAOCULAR-PRESSURE
    BRICKER, SRW
    MCGALLIARD, JN
    MOSTAFA, SM
    ANAESTHESIA, 1990, 45 (01) : 36 - 39
  • [23] Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits
    Pereira, Fabiana Quartiero
    Bercht, Bernardo Stefano
    Soares, Mirian Gomes
    Bittencourt da Mota, Mauricio Grillo
    Tadeu Pigatto, Joao Antonio
    VETERINARY OPHTHALMOLOGY, 2011, 14 (05) : 321 - 326
  • [24] Reliability and reproducibility of introcular pressure (IOP) measurement with the Icare® Home rebound tonometer (model TA022) and comparison with Goldmann applanation tonometer in glaucoma patients
    Valero, B.
    Fenolland, J. -R.
    Rosenberg, R.
    Sendon, D.
    Mesnard, C.
    Sigaux, M.
    Giraud, J. -M.
    Renard, J. -P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (10): : 865 - 875
  • [25] Measurement of intraocular pressure using the NT-4000: A new non-contact tonometer equipped with pulse synchronous measurement function
    Yaoeda, K
    Shirakashi, M
    Fukushima, A
    Funaki, S
    Funaki, H
    Ofuchi, N
    Nakatsue, T
    Abe, H
    JOURNAL OF GLAUCOMA, 2005, 14 (03) : 201 - 205
  • [26] A comparison of postural and diurnal variations in intraocular pressure using the iCare rebound tonometer and Perkins applanation tonometer in admitted adults in Kenya
    Chikasirimobi, Timothy G.
    Ndinyo, Mercy
    Ondieki, Maxine N.
    Miti, Isaac
    Ejiochi-Iyoke, Ndidi J.
    Osuagwu, Uchechukwu L.
    Zeried, Ferial M.
    Agho, Kingsley
    Ogbuehi, Kelechi C.
    Mashige, Khathutshelo P.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2021, 80 (01):
  • [27] Comparison of intraocular pressure measurement with Schiotz tonometer and Tono-Pen Vet tonometer in healthy dogs
    Wrzesniewska, Karolina
    Madany, Jacek
    Winiarczyk, Dagmara
    JOURNAL OF VETERINARY RESEARCH, 2018, 62 (02) : 243 - 247
  • [28] Intraocular pressure measurements with the newly reconfigured Ocuton S*TT-MV self-tonometer in comparison to Goldmann applanation tonometry in glaucoma patients
    Lanfermann, Elena
    Juergens, Clemens
    Grossjohann, Rico
    Antal, Susanna
    Tost, Frank
    MEDICAL SCIENCE MONITOR, 2009, 15 (11): : CR556 - CR562
  • [29] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Luebke, Jan
    Bryniok, L.
    Neuburger, M.
    Jordan, J. F.
    Boehringer, D.
    Reinhard, T.
    Wecker, T.
    Anton, A.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2517 - 2521
  • [30] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Jan Luebke
    L. Bryniok
    M. Neuburger
    J. F. Jordan
    D. Boehringer
    T. Reinhard
    T. Wecker
    A. Anton
    International Ophthalmology, 2019, 39 : 2517 - 2521