HEMATOPOIETIC BONE-MARROW IN THE ADULT KNEE - SPIN-ECHO AND OPPOSED-PHASE GRADIENT-ECHO MR IMAGING

被引:0
|
作者
LANG, P [1 ]
FRITZ, R [1 ]
MAJUMDAR, S [1 ]
VAHLENSIECK, M [1 ]
PETERFY, C [1 ]
GENANT, HK [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,M-392,SAN FRANCISCO,CA 94143
关键词
MR-IMAGING; KNEE; BONE MARROW;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hematopoietic bone marrow in the distal femur of the adult may be mistaken for a pathologic marrow process in magnetic resonance imaging of the knee. We investigated the incidence of hematopoietic marrow in the distal femur in a series of 51 adult patients and compared spin-echo (TR/TE in ms: 500/35, 2000/80) and opposed-phase gradient-echo (0.35 T, TR/TE in ms: 1000/30, theta = 75-degrees) magnetic resonance images. Zones with intermediate to low signal intensity on T1-weighted spin-echo and opposed-phase gradient-echo sequences representing hematopoietic marrow within high signal intensity fatty marrow were observed in 18 of the 51 patients. Five patterns of marrow signal reduction were identified; type 0: uniform high signal, i.e., no signal change; type I, focal signal loss; type II, multifocal signal loss without confluence; type III, confluent signal loss; and type IV, complete homogeneous reduction in marrow signal. Opposed-phase gradient-echo sequences demonstrated markedly greater red-yellow marrow contrast than conventional spin-echo sequences. Follow-up studies in three patients using a gradient-echo sequence with TE varying from 10 to 21 ms at 1-ms increments showed a cyclic increase and decrease in red and yellow marrow signal intensity depending on the TE. The contribution of intravoxel chemical shift effects on red-yellow marrow contrast in opposed-phase gradient-echo images was verified by almost complete cancellation of the TE-dependent marrow signal oscillation with use of a chemically selective pulse presaturating the water protons. Hematopoietic marrow in the adult distal femur in the absence of hematologic abnormalities is found primarily in women of menstruating age. It may be residual and may represent a biologic variation in the normal adult pattern of red-yellow marrow distribution. Reconverted red marrow appears to be related to increased erythrocyte demand. Residual and reconverted red marrow should not be mistaken for bone marrow malignancy. Opposed-phase gradient-echo imaging is easily implemented and appears ideally suited to monitor the distribution of hematopoietic marrow as a function of age and erythrocyte demand in vivo.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [1] RESIDUAL AND RECONVERTED HEMATOPOIETIC MARROW IN THE DISTAL FEMUR - SPIN-ECHO AND OPPOSED-PHASE GRADIENT-ECHO MRI
    LANG, P
    FRITZ, R
    VAHLENSIECK, M
    MAJUMDAR, S
    BERTHEZENE, Y
    GRAMPP, S
    GENANT, HK
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (01): : 89 - 95
  • [2] MR IMAGING OF BONE-MARROW WITH GRADIENT ECHO SEQUENCES .1. CONTRAST CONDITIONS OF PHASE-IDENTICAL AND OPPOSED-PHASE GRADIENT ECHO SEQUENCES
    HOSTEN, N
    SANDER, B
    SCHORNER, W
    HACKL, A
    HENKES, H
    SCHUBEUS, P
    NEUMANN, K
    FELIX, R
    SCHNEIDER, V
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (06): : 614 - 620
  • [3] MRI of bone marrow: opposed-phase gradient-echo sequences with long repetition time
    Seiderer, M
    Staebler, A
    Wagner, H
    EUROPEAN RADIOLOGY, 1999, 9 (04) : 652 - 661
  • [4] MRI of bone marrow: opposed-phase gradient-echo sequences with long repetition time
    M. Seiderer
    A. Staebler
    H. Wagner
    European Radiology, 1999, 9 : 652 - 661
  • [5] MULTIPLE-MYELOMA - SCREENING BY GD-DTPA ENHANCED OPPOSED-PHASE GRADIENT-ECHO MR IMAGING
    HOSTEN, N
    SCHORNER, W
    NEUMANN, K
    SANDER, B
    OERTEL, J
    KIRSCH, A
    SCHUBEUS, P
    CORDES, M
    FELIX, R
    HUHN, D
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (01): : 53 - 58
  • [6] Spin-echo and 3D gradient-echo imaging of the knee joint: A clinical and histopathological comparison
    Guckel, C
    Jundt, G
    Schnabel, K
    Gachter, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 25 - 33
  • [7] Osteodensitometry of human heel bones by MR spin-echo imaging: Comparison with MR gradient-echo imaging and quantitative computed tomography
    Machann, J
    Raible, A
    Schnatterbeck, P
    Lutz, O
    Claussen, CD
    Schick, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (02) : 147 - 155
  • [8] Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging:: features on conventional spin-echo, fast spin-echo and gradient-echo pulse sequences
    Precetti-Morel, S
    Bellin, MF
    Ghebontni, L
    Zaïm, S
    Opolon, P
    Poynard, T
    Mathurin, P
    Cluzel, P
    EUROPEAN RADIOLOGY, 1999, 9 (08) : 1535 - 1542
  • [9] SCREENING FOR SKELETAL METASTASES OF THE SPINE AND PELVIS - GRADIENT-ECHO OPPOSED-PHASE MRI COMPARED WITH BONE-SCINTIGRAPHY
    NEUMANN, K
    HOSTEN, N
    VENZ, S
    EUROPEAN RADIOLOGY, 1995, 5 (03) : 276 - 284
  • [10] Value of opposed-phase gradient-echo technique in distinguishing between benign and malignant vertebral lesions
    Zampa, V
    Cosottini, M
    Michelassi, MC
    Ortori, S
    Bruschini, L
    Bartolozzi, C