During the past 10 years intense effort has been directed toward the development of biosensors. No goal has been more important than the realization of continuous blood glucose monitoring as an aid to diabetes therapy. Attainment of this goal, however, is made elusive by the need to consider the specific analytical requirements of this special application. In this REPORT our aim is to describe the nature of the analytical problem from chemical and clinical perspectives and to explore possible solutions. © 1992, American Chemical Society. All rights reserved.
引用
收藏
页码:A381 / A386
页数:6
相关论文
共 32 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[3]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[4]   RENAL REPLACEMENT THERAPY IN PATIENTS WITH DIABETIC NEPHROPATHY, 1980-1985 [J].
BRUNNER, FP ;
BRYNGER, H ;
CHALLAH, S ;
FASSBINDER, W ;
GEERLINGS, W ;
SELWOOD, NH ;
TUFVESON, G ;
WING, AJ .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1988, 3 (05) :585-595
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]   SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS [J].
CLAREMONT, DJ ;
SAMBROOK, IE ;
PENTON, C ;
PICKUP, JC .
DIABETOLOGIA, 1986, 29 (11) :817-821
[7]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[8]  
DCCT Res Grp, 1987, DIABETES CARE, V10, P1
[9]   ASSESSMENT OF SUBCUTANEOUS GLUCOSE-CONCENTRATION - VALIDATION OF THE WICK TECHNIQUE AS A REFERENCE FOR IMPLANTED ELECTROCHEMICAL SENSORS IN NORMAL AND DIABETIC DOGS [J].
FISCHER, U ;
ERTLE, R ;
ABEL, P ;
REBRIN, K ;
BRUNSTEIN, E ;
VONDORSCHE, HH ;
FREYSE, EJ .
DIABETOLOGIA, 1987, 30 (12) :940-945
[10]  
FISCHER U, 1989, BIOMED BIOCHIM ACTA, V48, P965