Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement

被引:0
作者
Sa, Michel Pompeu [1 ,2 ]
Jacquemyn, Xander [3 ]
Van den Eynde, Jef [3 ]
Tasoudis, Panagiotis [2 ]
Dokollari, Aleksander [2 ]
Torregrossa, Gianluca [1 ,2 ]
Sicouri, Serge [2 ]
Clavel, Marie-Annick [4 ,5 ]
Pibarot, Philippe [4 ,5 ]
Ramlawi, Basel [1 ,2 ]
机构
[1] Main Line Hlth, Lankenau Heart Inst, Lankenau Med Ctr, Dept Cardiothorac Surg, Wynnewood, PA USA
[2] Lankenau Inst Med Res, Dept Cardiothorac Surg Res, Wynnewood, PA USA
[3] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[4] Inst Univ Cardiol & Pneumol Quebec, Ctr Rech, Quebec City, PQ, Canada
[5] Univ Laval, Fac Med, Dept Med, Quebec City, PQ, Canada
关键词
  cardiac surgical procedures; cardiovascular surgical procedures; heart valve diseases; heart valve prosthesis implantation; meta-analysis; transcatheter aortic valve replacement;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND It remains controversial whether prosthesis-patient mismatch (PPM) (in general considered moderate if indexed effective orifice area is 0.65-0.85 cm2/m2 and severe when <0.65 cm2/m2) affects the outcomes after transcatheter aortic valve replacement (TAVR).OBJECTIVES The purpose of this study is to evaluate the time-varying effects and association of PPM with the risk of overall mortality.METHODS Study-level meta-analysis of reconstructed time-to-event data from Kaplan-Meier curves of studies published by December 30, 2021.RESULTS In total, 23 studies met our eligibility criteria and included a total of 81,969 patients included in the Kaplan-Meier curves (19,612 with PPM and 62,357 without PPM). Patients with moderate/severe PPM had a significantly higher risk of mortality compared with those without PPM (HR: 1.09 [95% CI: 1.04-1.14]; P < 0.001). In the first 30 months after the procedure, mortality rates were significantly higher in the moderate/severe PPM group (HR: 1.1 [95% CI: 1.05-1.16]; P < 0.001). In contrast, the landmark analysis beyond 30 months yielded a reversal of the HR (0.83 [95% CI: 0.68-1.01]; P = 0.064), but without statistical significance. In the sensitivity analysis, although the authors observed that severe PPM showed higher risk of mortality in comparison with no PPM (HR: 1.25 [95% CI: 1.16-1.36]; P < 0.001), they did not observe a statistically significant difference for mortality between moderate PPM and no PPM (HR: 1.03 [95% CI: 0.96-1.10]; P = 0.398). CONCLUSIONS Severe PPM, but not moderate PPM, was associated with higher risk of mortality following TAVR. These results provide support to implementation of preventive strategies to avoid severe PPM following TAVR. (J Am Coll Cardiol Img 2023;16:298-310) (c) 2023 by the American College of Cardiology Foundation.
引用
收藏
页码:298 / 310
页数:13
相关论文
共 40 条
[1]   Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients [J].
Barros de Oliveira Sa, Michel Pompeu ;
Barros de Carvalho, Martinha Millianny ;
Sobral Filho, Dario Celestino ;
Pereira Cavalcanti, Luiz Rafael ;
Rayol, Sergio da Costa ;
Silva Diniz, Roberto Gouvea ;
Menezes, Alexandre Motta ;
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Lima, Ricardo Carvalho .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (01) :44-54
[2]   Patient Prosthesis Mismatch After SAVR and TAVR [J].
Bleiziffer, Sabine ;
Rudolph, Tanja K. .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[3]   Valve Prosthesis-Patient Mismatch (VP-PM) A Long-Term Perspective [J].
Daneshvar, Samuel A. ;
Rahimtoola, Shahbudin H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (13) :1123-1135
[4]   Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation [J].
Ewe, See Hooi ;
Muratori, Manuela ;
Delgado, Victoria ;
Pepi, Mauro ;
Tamborini, Gloria ;
Fusini, Laura ;
Klautz, Robert J. M. ;
Gripari, Paola ;
Bax, Jeroen J. ;
Fusari, Melissa ;
Schalij, Martin J. ;
Marsan, Nina Ajmone .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) :1910-1918
[5]   Prosthesis-patient mismatch defined by cardiac computed tomography versus echocardiography after transcatheter aortic valve replacement [J].
Fukui, Miho ;
Garcia, Santiago ;
Lesser, John R. ;
Gossl, Mario ;
Tang, Liang ;
Caye, David ;
Newell, Marc ;
Hashimoto, Go ;
Lopes, Bernardo B. C. ;
Stanberry, Larissa, I ;
Enriquez-Sarano, Maurice ;
Pibarot, Philippe ;
Hahn, RebeccaT ;
Sorajja, Paul ;
Cavalcante, Joao L. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (05) :403-411
[6]   Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research [J].
Genereux, Philippe ;
Piazza, Nicolo ;
Alu, Maria C. ;
Nazif, Tamim ;
Hahn, Rebecca T. ;
Pibarot, Philippe ;
Bax, Jeroen J. ;
Leipsic, Jonathon A. ;
Blanke, Philipp ;
Blackstone, Eugene H. ;
Finn, Matthew T. ;
Kapadia, Samir ;
Linke, Axel ;
Mack, Michael J. ;
Makkar, Raj ;
Mehran, Roxana ;
Popma, Jeffrey J. ;
Reardon, Michael ;
Rodes-Cabau, Josep ;
Van Mieghem, Nicolas M. ;
Webb, John G. ;
Cohen, David J. ;
Leon, Martin B. .
EUROPEAN HEART JOURNAL, 2021, 42 (19) :1825-1857
[7]  
GRAMBSCH PM, 1994, BIOMETRIKA, V81, P515
[8]   Enhanced secondary analysis of survival data: reconstructing the data from published Kaplan-Meier survival curves [J].
Guyot, Patricia ;
Ades, A. E. ;
Ouwens, Mario J. N. M. ;
Welton, Nicky J. .
BMC MEDICAL RESEARCH METHODOLOGY, 2012, 12
[9]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529
[10]   Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry [J].
Herrmann, Howard C. ;
Daneshvar, Samuel A. ;
Fonarow, Gregg C. ;
Stebbins, Amanda ;
Vemulapalli, Sreekanth ;
Desai, Nimesh D. ;
Malenka, David J. ;
Thourani, Vinod H. ;
Rymer, Jennifer ;
Kosinski, Andrzej S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2701-2711