MECHANICAL IMPEDANCES OF LUNGS AND CHEST-WALL IN THE CAT

被引:140
作者
HANTOS, Z [1 ]
ADAMICZA, A [1 ]
GOVAERTS, E [1 ]
DAROCZY, B [1 ]
机构
[1] SZENT GYORGYI ALBERT MED UNIV,INST EXPTL SURG,H-6720 SZEGED,HUNGARY
关键词
PULMONARY RESISTANCE; PULMONARY ELASTANCE; CHEST WALL RESISTANCE; CHEST WALL ELASTANCE; TISSUE HYSTERESIVITY; TISSUE NONLINEARITY; FORCED OSCILLATIONS;
D O I
10.1152/jappl.1992.73.2.427
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In nine anesthetized and paralyzed cats, the mechanical impedances of the total respiratory system (Zrs) and the lungs (ZL) were measured with small-volume pseudorandom forced oscillations between 0.2 and 20 Hz. ZL was measured after thoracotomy, and chest wall impedance (Zw) was calculated as Zw = Zrs - ZL. All impedances were determined by using input airflow [input impedance (Z(i))] and output flow measured with a body box [transfer impedance (Z(t))]. The differences between Z(i) and Z(t) were small for Zrs and negligible for ZL. At 0.2 Hz, the real and imaginary parts Of ZL amounted to 33 +/- 4 and 35 +/- 3% (SD), respectively, Of Zrs. Up to 8 Hz, all impedances were consistent with a model containing a frequency-independent resistance and inertance and a constant-phase tissue part (G - jH)/omega(alpha), where G and H are coefficients for damping and elastance, respectively, omega is angular frequency, and a determines the frequency dependence of the real and imaginary parts. G/H was higher for Zw than for ZL (0.29 +/- 0.05 vs. 0.22 +/- 0.04, P < 0.01). In four cats, the amplitude dependence of impedances was studied: between oscillation volumes of 0.8 and 3 ml, GL, HL, Gw, and Hw decreased on average by 3, 9, 26, and 29%, respectively, whereas the change in G/H was small for both ZL (7%) and Zw (-4%). The values of H were two to three times higher than the quasistatic elastances estimated with greater volume changes (>20 ml).
引用
收藏
页码:427 / 433
页数:7
相关论文
共 28 条
[1]   AMPLITUDE DEPENDENCY OF REGIONAL CHEST WALL RESISTANCE AND ELASTANCE AT NORMAL BREATHING FREQUENCIES [J].
BARNAS, GM ;
MACKENZIE, CF ;
SKACEL, M ;
HEMPLEMAN, SC ;
WICKE, KM ;
SKACEL, CM ;
LORING, SH .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (01) :25-30
[2]   PROPORTIONALITY BETWEEN CHEST-WALL RESISTANCE AND ELASTANCE [J].
BARNAS, GM ;
STAMENOVIC, D ;
FREDBERG, JJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) :511-515
[3]   MECHANICAL COUPLING OF THE RIB CAGE, ABDOMEN, AND DIAPHRAGM THROUGH THEIR AREA OF APPOSITION [J].
BOYNTON, BR ;
BARNAS, GM ;
DADMUN, JT ;
FREDBERG, JJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (03) :1235-1244
[4]   NATURAL FREQUENCY, DAMPING FACTOR AND INERTANCE OF THE CHEST-LUNG SYSTEM IN CATS [J].
BRODY, AW ;
DUBOIS, AB ;
NISELL, OI ;
ENGELBERG, J .
AMERICAN JOURNAL OF PHYSIOLOGY, 1956, 186 (01) :142-148
[5]   DETERMINATION OF TISSUE, AIRWAY AND TOTAL RESISTANCE TO RESPIRATION IN CATS [J].
BRODY, AW ;
DUBOIS, AB .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 9 (02) :213-218
[6]  
Csendes T., 1988, Acta Cybernetica, V8, P361
[7]   GENERATION OF OPTIMUM PSEUDORANDOM SIGNALS FOR RESPIRATORY IMPEDANCE MEASUREMENTS [J].
DAROCZY, B ;
HANTOS, Z .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1990, 25 (01) :21-31
[8]   ON THE IMPERFECT ELASTICITY OF LUNG-TISSUE [J].
FREDBERG, JJ ;
STAMENOVIC, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (06) :2408-2419
[9]   INTERRUPTER TECHNIQUE FOR MEASUREMENT OF RESPIRATORY MECHANICS IN ANESTHETIZED CATS [J].
GOTTFRIED, SB ;
ROSSI, A ;
CALVERLEY, PMA ;
ZOCCHI, L ;
MILICEMILI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (03) :681-690
[10]   MODELING OF LOW-FREQUENCY PULMONARY IMPEDANCE IN DOGS [J].
HANTOS, Z ;
DAROCZY, B ;
CSENDES, T ;
SUKI, B ;
NAGY, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 68 (03) :849-860