We studied surface adherence and its effects on color Doppler jet areas and color encoding in an in vitro model with a noncompliant receiving chamber into which a steady flow jet was directed parallel to either a straight or a curved surface adjacent to and 4 mm away from the inflow orifice (1.50 mm2) with the control condition being a free jet matched for flow rates and driving pressures. Jets were imaged perpendicular to the plane of the surface, the plane in which most clinical images of jet-surface interactions are obtained. Ten different flow rates ranging from 0.13 to 0.30 l/min were used. Surface-adherent jet areas were smaller than control jets for every driving pressure-volume combination (paired t test, p < 0.01). Computer analysis of color Doppler images showed more green and blue (reverse flow) pixels on the surface side of the adherent jets than the control jets (p < 0.05), suggesting that viscous energy loss and flow deceleration and reversal play a role in the jet-surface interaction. Analysis of variance demonstrated that linear regression slopes of flow rate versus jet area for surface jets were lower (slopes, 11-21 cm2/l/min; r = 0.95-0.97) than those for the control (slope, 33 cm2/l/min; r = 0.97) (p < 0.0001). Surface adherence (Coanda effect) influences jet size and color encoding, causing smaller color Doppler jet areas and greater variance and reverse velocity encoding.
引用
收藏
页码:333 / 341
页数:9
相关论文
共 50 条
  • [1] ANALYSIS OF COLOR DOPPLER - AN INVITRO STUDY OF THE EFFECTS OF JET VELOCITY ON DOPPLER COLOR FLOW MAPPING
    NANNA, M
    FENG, X
    HOLEN, J
    GRAMIAK, R
    MELTZER, RS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A110 - A110
  • [2] FACTORS AFFECTING JET VISUALIZATION BY COLOR FLOW MAPPING DOPPLER ECHO - INVITRO STUDIES
    SAHN, DJ
    CHUNG, KJ
    TAMURA, T
    MEYER, T
    YOGANATHAN, AP
    MCMILLAN, S
    SUNG, HW
    CIRCULATION, 1986, 74 (04) : 271 - 271
  • [3] COLOR DOPPLER FLOW MAPPING
    SIMPSON, IA
    CAMM, AJ
    BRITISH MEDICAL JOURNAL, 1990, 300 (6716): : 1 - 2
  • [4] DOPPLER COLOR FLOW MAPPING
    SWITZER, DF
    NANDA, NC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03): : 403 - 416
  • [5] MITRAL REGURGITANT JET SIZE BY DOPPLER COLOR FLOW MAPPING - INFLUENCE OF AFTERLOAD
    CZER, L
    MAURER, G
    LIN, SL
    RESSER, K
    BOLGER, A
    MATLOFF, J
    CLINICAL RESEARCH, 1987, 35 (03): : A272 - A272
  • [6] COLOR DOPPLER FLOW MAPPING STUDIES OF JET FORMATION IN HYPERTROPHIC CARDIOMYOPATHY (HCM)
    HOIT, B
    SAHN, DJ
    DALTON, N
    SMITH, SC
    YUN, Y
    DITTRICH, H
    CIRCULATION, 1985, 72 (04) : 447 - 447
  • [7] INTRAOPERATIVE DOPPLER FLOW STUDIES - EMPHASIS ON COLOR MAPPING
    DUNCAN, WJ
    TYRRELL, MJ
    BHARADWAJ, B
    IYENGAR, SKS
    CANADIAN JOURNAL OF SURGERY, 1988, 31 (05) : 313 - 318
  • [8] ATRIAL INFLOW CAN ALTER COLOR DOPPLER REGURGITANT JET AREA - INVITRO STUDIES
    GRIMES, RY
    WALKER, PG
    NYARKO, SJ
    YOGANATHAN, AP
    CIRCULATION, 1992, 86 (04) : 318 - 318
  • [9] DOPPLER ECHOCARDIOGRAPHY AND COLOR FLOW MAPPING
    COPEL, JA
    HOBBINS, JC
    KLEINMAN, CS
    OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 1991, 18 (04) : 845 - 851
  • [10] THE FLOW MAPPING METHOD USING COLOR DOPPLER DEVICE
    CHIHARA, K
    HYOUTANI, H
    SHIRAE, K
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 433 - 434