Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device

被引:16
作者
Erqou, Sebhat [1 ,2 ]
Kormos, Robert L. [3 ]
Wang, Norman C. [3 ]
McNamara, Dennis M. [3 ]
Bazaz, Raveen [3 ]
机构
[1] Brown Univ, Dept Med, Alpert Med Sch, Providence, RI 02912 USA
[2] Providence VA Med Ctr, Dept Med, Providence, RI 02908 USA
[3] Univ Pittsburgh, Med Ctr, Heart & Vasc Inst, Pittsburgh, PA USA
关键词
D O I
10.1155/2018/6195045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is an increasing prevalence of patients with concomitant implantable cardioverter-defibrillators (ICDs) and left ventricular devices (LVADs). The potential for negative interactions between these continually evolving technologies is a valid concern. Previously reported interactions include inappropriate ICD therapy and interference with ICD telemetry function. Understanding the nature of such interactions and developing a comprehensive strategy to approach such situations are important. In this report, we describe a case of electromagnetic interference from LVAD inhibiting the pacing function of an ICD that was corrected by reprograming the device. We would encourage investigators to review patients with ICD and LVAD in their institutions in order to help assess the frequency and nature of these and other interactions.
引用
收藏
页数:4
相关论文
共 8 条
  • [1] Chhabra Lovely, 2015, Conn Med, V79, P351
  • [2] Left Ventricular Mechanical Assist Devices and Cardiac Device Interactions: An Observational Case Series
    Foo, David
    Walker, Bruce D.
    Kuchar, Dennis L.
    Thorburn, Charles W.
    Tay, Andre
    Hayward, Christopher S.
    Macdonald, Peter
    Keogh, Anne
    Kotlyar, Eugene
    Spratt, Philip
    Jansz, Paul
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07): : 879 - 887
  • [3] "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator
    Jacob, Sony
    Cherian, Prasad K.
    Ghumman, Waqas S.
    Das, Mithilesh K.
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 28 (03) : 221 - 225
  • [4] Matthews JC, 2007, J CARDIOVASC ELECTR, V18, P1107, DOI 10.1111/j.1540-8167.2007.00805.x
  • [5] Inappropriate implantable cardioverter-defibrillator therapy due to electromagnetic interference in patient with a HeartWare HVAD left ventricular assist device
    Mozes, Abram
    DeNofrio, David
    Duc Thinh Pham
    Homoud, Munther K.
    [J]. HEART RHYTHM, 2011, 8 (05) : 778 - 780
  • [6] Interactions between a Left Ventricular Assist Device and Implantable Cardioverter-Defibrillator
    Netzler, Peter C.
    Vasuki, Nagavardhan
    Peura, Jennifer L.
    Gold, Michael R.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (09): : e272 - e273
  • [7] Oswald Hanno, 2009, Interact Cardiovasc Thorac Surg, V8, P579, DOI 10.1510/icvts.2009.202077
  • [8] Long-term use of a left ventricular assist device for end-stage heart failure
    Rose, EA
    Gelijns, AC
    Moskowitz, AJ
    Heitjan, DF
    Stevenson, LW
    Dembitsky, W
    Long, JW
    Ascheim, DD
    Tierney, AR
    Levitan, RG
    Watson, JT
    Meier, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (20) : 1435 - 1443