STUDY OF THE MECHANISM OF ULTRASOUND ANGIOPLASTY FROM HUMAN THROMBI AND BOVINE AORTA

被引:48
作者
ROSENSCHEIN, U
FRIMERMAN, A
LANIADO, S
MILLER, HI
机构
[1] Department of Cardiology, Tel Aviv Medical Center, Tel Aviv
关键词
D O I
10.1016/0002-9149(94)90560-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ultrasound angioplasty is a newly developed technology for percutaneous arterial recanalization. Data suggest that ultrasound is particularly effective in ablating fresh thrombi. Arterial walls were found to be resistant to ultrasound ablation. Thrombi, aortic wall segments, and hydroxyproline gelatin were studied in vitro to determine their respective ablation rates. The elasticity of the samples was determined is a force-mode apparatus. The cavitation threshold was determined in an arterial phantom apparatus. Thrombi displayed ablation rates that were >20 times higher than those of aortic wall samples (591 +/- 82 vs 25 +/- 14 mg/s, p <0.001). The differences in ablation rates were accompanied by significantly lower elasticities in the thrombus group compared with those in the aortic wall group (0.16 +/- 0.05 vs 312 +/- 37 g/cm(2), p <0.001). Experiments with hydroxyproline gelatin suggest a negative correlation (r = -0.90) between elasticity and ultrasound ablation. Ultrasound ablation of thrombi was evident only above the cavitation threshold. Thus, ultrasound angioplasty has the potential to induce the selective injury required for successful transluminal intervention in the treatment of thrombus-rich lesions.
引用
收藏
页码:1263 / 1266
页数:4
相关论文
共 14 条
[1]  
[Anonymous], 1988, ULTRASOUND ITS CHEM
[2]  
APFEL R, 1981, METHODS EXPT PHYSICS, P19
[3]  
DETWILER PW, 1991, DIAGNOSTIC THERAPEUT, V1425, P149
[4]   THE TEMPERATURE OF CAVITATION [J].
FLINT, EB ;
SUSLICK, KS .
SCIENCE, 1991, 253 (5026) :1397-1399
[5]  
FUNG YC, 1981, BIOMECHANICS MECH PR, P23
[6]   ULTRASONIC THROMBUS ABLATION - INVITRO ASSESSMENT OF A NOVEL DEVICE FOR INTRACORONARY USE [J].
HARTNELL, GG ;
SAXTON, JM ;
FRIEDL, SE ;
ABELA, GS ;
ROSENSCHEIN, U .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1993, 6 (01) :69-76
[7]  
HENRY GE, 1954, SCI AM, V5, P55
[8]  
KOMOWSKI R, 1994, CIRCULATION, V89, P339
[9]   ULTRASOUND-ENHANCED POLYMER DEGRADATION AND RELEASE OF INCORPORATED SUBSTANCES - (CONTROLLED RELEASE DRUG DELIVERY SYSTEMS) [J].
KOST, J ;
LEONG, K ;
LANGER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (20) :7663-7666
[10]   EFFECT OF ULTRASOUND ON TISSUE-TYPE PLASMINOGEN-ACTIVATOR INDUCED THROMBOLYSIS [J].
LAUER, CG ;
BURGE, R ;
TANG, DB ;
BASS, BG ;
GOMEZ, ER ;
ALVING, BM .
CIRCULATION, 1992, 86 (04) :1257-1264