A MODULAR 4-PI COUNTER FOR BETA-DELAYED NEUTRONS

被引:4
作者
KUNZE, V [1 ]
SCHMIDTOTT, WD [1 ]
BOSCHWICKE, U [1 ]
BOTTGER, R [1 ]
KLEIN, H [1 ]
机构
[1] PHYS TECH BUNDESANSTALT,D-38116 BRAUNSCHWEIG,GERMANY
关键词
D O I
10.1016/0168-9002(95)00125-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the construction of a detector array for low-energy beta-delayed neutrons consisting of sixteen NE 213 scintillation counters. Three pulse-shape discrimination techniques were compared, with special emphasis on the discrimination of neutrons from gamma-rays in the energy region down to 50 keVee (keV electron equivalent). The efficiency as a function of neutron energy was obtained by comparing the precisely known neutron spectrum from the spontaneous fission of Cf-252 and the neutron distribution measured in coincidence with the fission events. The neutron energy was determined with the time-of-flight (TOF) technique. In order to examine the light output function L(E(p)) for recoil protons, a careful energy calibration was done by fitting the Compton edges from standard gamma-ray sources. Neutron efficiencies were also calculated with a Monte Carlo code. Agreement between measured and calculated efficiency curves was observed for two differently shaped detectors and neutron flight paths of 1 and 3 m. This correspondence justifies the efficiency calculation for the 4 pi array with the source in the center. For neutron energies above 800 keV an error of less than 5% in detection efficiency can be reached.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 21 条
[1]   A NE213 LIQUID SCINTILLATOR, NEUTRON DETECTOR DESIGNED FOR LIFETIME MEASUREMENTS OF VERY NEUTRON-RICH NUCLEI [J].
BAZIN, D ;
MUELLER, AC ;
SCHMIDTOTT, WD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (01) :117-127
[2]  
BOTTGER R, 1990, NUCL SCI ENG, V106, P377
[3]   RESPONSE OF NE213 LIQUID SCINTILLATION DETECTORS TO HIGH-ENERGY PHOTONS (E-GAMMA-GREATER-THAN 3 MEV) [J].
BUERMANN, L ;
DING, S ;
GULDBAKKE, S ;
KLEIN, H ;
NOVOTNY, T ;
TICHY, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (03) :483-492
[4]   THE NEUTRON DETECTION EFFICIENCY OF NE213 DETECTORS MEASURED BY MEANS OF A CF-252 SOURCE [J].
CUB, J ;
FINCKH, E ;
GEBHARDT, K ;
GEISSDORFER, K ;
LIN, R ;
STRATE, J ;
KLEIN, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2) :217-221
[5]   GAMMA-CALIBRATION OF NE-213 SCINTILLATION-COUNTERS [J].
DIETZE, G ;
KLEIN, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 193 (03) :549-556
[6]  
DIETZE G, 1982, PTBND22 BER
[7]  
DIETZE G, 1991, UNPUB HOW USE VERSIO
[8]   THE GSI PROJECTILE FRAGMENT SEPARATOR (FRS) - A VERSATILE MAGNETIC SYSTEM FOR RELATIVISTIC HEAVY-IONS [J].
GEISSEL, H ;
ARMBRUSTER, P ;
BEHR, KH ;
BRUNLE, A ;
BURKARD, K ;
CHEN, M ;
FOLGER, H ;
FRANCZAK, B ;
KELLER, H ;
KLEPPER, O ;
LANGENBECK, B ;
NICKEL, F ;
PFENG, E ;
PFUTZNER, M ;
ROECKL, E ;
RYKACZEWSKI, K ;
SCHALL, I ;
SCHARDT, D ;
SCHEIDENBERGER, C ;
SCHMIDT, KH ;
SCHROTER, A ;
SCHWAB, T ;
SUMMERER, K ;
WEBER, M ;
MUNZENBERG, G ;
BROHM, T ;
CLERC, HG ;
FAUERBACH, M ;
GAIMARD, JJ ;
GREWE, A ;
HANELT, E ;
KNODLER, B ;
STEINER, M ;
VOSS, B ;
WECKENMANN, J ;
ZIEGLER, C ;
MAGEL, A ;
WOLLNIK, H ;
DUFOUR, JP ;
FUJITA, Y ;
VIEIRA, DJ ;
SHERRILL, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 70 (1-4) :286-297
[9]  
GUILLEMAUDMUELL, 1989, Z PHYS A, V332, P189
[10]  
GULDBAKKE S, 1995, ASTM STP, V1228, P280