MR-Based Cardiac and Respiratory Motion-Compensation Techniques for PET-MR Imaging

被引:35
作者
Munoz, Camila [1 ]
Kolbitsch, Christoph [1 ]
Reader, Andrew J. [1 ]
Marsden, Paul [1 ]
Schaeffter, Tobias [1 ]
Prieto, Claudia [1 ]
机构
[1] Kings Coll London, St Thomas Hosp, Dept Biomed Engn, Div Imaging Sci & Biomed Engn, 4th Floor,Lambeth Wing,Westminster Bridge Rd, London SE1 7EH, England
基金
英国工程与自然科学研究理事会;
关键词
Motion compensation; Respiratory motion; Cardiac motion; PET-MR imaging;
D O I
10.1016/j.cpet.2015.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac and respiratory motion cause image quality degradation in PET imaging, affecting diagnostic accuracy of the images. Whole-body simultaneous PET-MR scanners allow for using motion information estimated from MR images to correct PET data and produce motion-compensated PET images. This article reviews methods that have been proposed to estimate motion from MR images and different techniques to include this information in PET reconstruction, in order to overcome the problem of cardiac and respiratory motion in PET-MR imaging. MR-based motion correction techniques significantly increase lesion detectability and contrast, and also improve accuracy of uptake values in PET images.
引用
收藏
页码:179 / 191
页数:13
相关论文
共 53 条
[1]  
Ambwani S, 2011, I S BIOMED IMAGING, P1702, DOI 10.1109/ISBI.2011.5872732
[2]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[3]   MODEL OBSERVERS FOR ASSESSMENT OF IMAGE QUALITY [J].
BARRETT, HH ;
YAO, J ;
ROLLAND, JP ;
MYERS, KJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (21) :9758-9765
[4]   Investigation of MR-Based Attenuation Correction and Motion Compensation for Hybrid PET/MR [J].
Buerger, Christian ;
Tsoumpas, Charalampos ;
Aitken, Andrew ;
King, Andrew Peter ;
Schleyer, Paul ;
Schulz, Volkmar ;
Marsden, Paul K. ;
Schaeffter, Tobias .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) :1967-1976
[5]   MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI [J].
Chun, Se Young ;
Reese, Timothy G. ;
Ouyang, Jinsong ;
Guerin, Bastien ;
Catana, Ciprian ;
Zhu, Xuping ;
Alpert, Nathaniel M. ;
El Fakhri, Georges .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) :1284-1291
[6]   MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems [J].
Dikaios, Nikolaos ;
Izquierdo-Garcia, David ;
Graves, Martin J. ;
Mani, Venkatesh ;
Fayad, Zahi A. ;
Fryer, Tim D. .
EUROPEAN RADIOLOGY, 2012, 22 (02) :439-446
[7]   Respiratory Motion Correction of PET using Motion Parameters from MR [J].
Dikaios, Nikolaos ;
Fryer, Tim D. .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :2806-2808
[8]  
Dutta J, 2013, I S BIOMED IMAGING, P800
[9]  
Fayad H, 2010, IEEE NUCL SCI CONF R, P2455, DOI 10.1109/NSSMIC.2010.5874229
[10]   The use of a generalized reconstruction by inversion of coupled systems (GRICS) approach for generic respiratory motion correction in PET/MR imaging [J].
Fayad, Hadi ;
Odille, Freddy ;
Schmidt, Holger ;
Wuerslin, Christian ;
Kuestner, Thomas ;
Felblinger, Jacques ;
Visvikis, Dimitris .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (06) :2529-2546