Multimodality imaging for the diagnosis and assessment of aortic stenosis severity

被引:2
作者
Davin, Laurent [1 ]
Dulgheru, Raluca [1 ]
Bernard, Anne [2 ,3 ]
Marchetta, Stella [1 ]
Pierard, Luc A. [1 ]
Lancellotti, Patrizio [1 ,4 ]
机构
[1] CHU Sart Tilman, Univ Liege Hosp, Heart Valve Clin, GIGA Cardiovasc Sci,Dept Cardiol, Liege, Belgium
[2] CHU Tours, Dept Cardiol, Tours, France
[3] Univ Tours, Tours, France
[4] Anthea Hosp, Grp Villa Maria Care & Res, Bari, Italy
关键词
Aortic stenosis; imaging; cardiac resonance imaging; computed tomography; echocardiography; guidelines; nuclear cardiology;
D O I
10.1080/14779072.2016.1213630
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Aortic stenosis (AS) is the most common cause of valvular heart disease. Imaging plays a major role in the diagnosis and evaluation of AS severity. Areas covered: The present review focuses on new emerging concepts in AS by stressing the substantial value of imaging into the understanding of the complex pathophysiology and management of AS. Expert commentary: Though, standard 2D echocardiography is often diagnostic multi-modality imaging can be required in patients with doubtful results or to refine the evaluation of AS.
引用
收藏
页码:1177 / 1188
页数:12
相关论文
共 79 条
[1]   Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Normal Ejection Fraction Is Associated With Severe Left Ventricular Dysfunction as Assessed by Speckle-Tracking Echocardiography A Multicenter Study [J].
Adda, Jerome ;
Mielot, Christopher ;
Giorgi, Roch ;
Cransac, Frederic ;
Zirphile, Xavier ;
Donal, Erwan ;
Sportouch-Dukhan, Catherine ;
Reant, Patricia ;
Laffitte, Stephane ;
Cade, Stephane ;
Le Dolley, Yvan ;
Thuny, Franck ;
Touboul, Nathalie ;
Lavoute, Cecile ;
Avierinos, Jean-Francois ;
Lancellotti, Patrizio ;
Habib, Gilbert .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (01) :27-35
[2]   Sex Differences in Aortic Valve Calcification Measured by Multidetector Computed Tomography in Aortic Stenosis [J].
Aggarwal, Shivani R. ;
Clavel, Marie-Annick ;
Messika-Zeitoun, David ;
Cueff, Caroline ;
Malouf, Joseph ;
Araoz, Philip A. ;
Mankad, Rekha ;
Michelena, Hector ;
Vahanian, Alec ;
Enriquez-Sarano, Maurice .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (01) :40-47
[3]   Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation [J].
Altiok, Ertunc ;
Koos, Ralf ;
Schroeder, Joerg ;
Brehmer, Kathrin ;
Hamada, Sandra ;
Becker, Michael ;
Mahnken, Andreas H. ;
Almalla, Mohammad ;
Dohmen, Guido ;
Autschbach, Ruediger ;
Marx, Nikolaus ;
Hoffmann, Rainer .
HEART, 2011, 97 (19) :1578-1584
[4]   Prognostic Significance of LGE by CMR in Aortic Stenosis Patients Undergoing Valve Replacement [J].
Barone-Rochette, Gilles ;
Pierard, Sophie ;
de Ravenstein, Christophe De Meester ;
Seldrum, Stephanie ;
Melchior, Julie ;
Maes, Frederic ;
Pouleur, Anne-Catherine ;
Vancraeynest, David ;
Pasquet, Agnes ;
Vanoverschelde, Jean-Louis ;
Gerber, Bernhard L. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (02) :144-154
[5]   Overestimation of catheter gradients by Doppler ultrasound in patients with aortic stenosis: A predictable manifestation of pressure recovery [J].
Baumgartner, H ;
Stefenelli, T ;
Niederberger, J ;
Schima, H ;
Maurer, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1655-1661
[6]   Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :1-25
[7]   B-Type natriuretic peptide in low-flow, low-gradient aortic stenosis - Relationship to hemodynamics and clinical outcome: Results from the multicenter truly or pseudo-severe aortic stenosis (TOPAS) study [J].
Bergler-Klein, Jutta ;
Mundigler, Gerald ;
Pibarot, Philippe ;
Burwash, Ian G. ;
Dumesnil, Jean G. ;
Blais, Claudia ;
Fuchs, Christina ;
Mohty, Dania ;
Beanlands, Rob S. ;
Hachicha, Zeineb ;
Walter-Publig, Nicole ;
Rader, Florian ;
Baumgartner, Helmut .
CIRCULATION, 2007, 115 (22) :2848-2855
[8]   Projected valve area at normal flow rate improves the assessment of stenosis severity in patients with low-flow, low-gradient aortic stenosis - The Multicenter TOPAS (truly or pseudo-severe aortic stenosis) study [J].
Blais, C ;
Burwash, IG ;
Mundigler, G ;
Dumesnil, JG ;
Loho, N ;
Rader, F ;
Baumgartner, H ;
Beanlands, RS ;
Chayer, B ;
Kadem, L ;
Garcia, D ;
Durand, LG ;
Pibarot, P .
CIRCULATION, 2006, 113 (05) :711-721
[9]   Reduced systemic arterial compliance impacts significantly on left ventricular afterload and function in aortic stenosis - Implications for diagnosis and treatment [J].
Briand, M ;
Dumesnil, JG ;
Kadem, L ;
Tongue, AG ;
Rieu, R ;
Garcia, D ;
Pibarot, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :291-298
[10]   Effect of Lipid Lowering With Rosuvastatin on Progression of Aortic Stenosis Results of the Aortic Stenosis Progression Observation: Measuring Effects of Rosuvastatin (ASTRONOMER) Trial [J].
Chan, Kwan Leung ;
Teo, Koon ;
Dumesnil, Jean G. ;
Ni, Andy ;
Tam, James .
CIRCULATION, 2010, 121 (02) :306-U247