Improved district heating network operation by the integration of high-temperature heat pumps

被引:12
作者
Sartor, Kevin [1 ]
Lemort, Vincent [1 ]
Dewallef, Pierre [1 ]
机构
[1] Univ Liege, Aerosp & Mech Engn Dept, Liege, Belgium
关键词
District heating network; heat pump; application test case; heat losses;
D O I
10.1080/14786451.2017.1383409
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Biomass combined heat and power (CHP) plants connected to district heating networks are a very good opportunity to increase the share of renewable sources into energy systems. Frequently, important consumers are connected to ensure a stable base heat demand throughout the year but they often have higher requirements in terms of temperature (i.e. steam), which involves a high level of temperature in the district heating network during the whole year and high levels of heat losses in the network. This contribution presents the possibility to decrease the level of temperature at which the district heating network operates and to use high-temperature heat pumps connected locally at the consumption point to produce steam when it is required. An investigation of the global design and integration through thermodynamic simulation models is realised for the University of Liege district heating network. This study is intended to determine the heat pump coefficient of performance and, therefore, to assess the balance between the savings in terms of heat losses and the additional heat pump electricity consumption.
引用
收藏
页码:842 / 856
页数:15
相关论文
共 38 条
[31]   Prediction of SOx and NOx emissions from a medium size biomass boiler [J].
Sartor, K. ;
Restivo, Y. ;
Ngendakumana, P. ;
Dewallef, P. .
BIOMASS & BIOENERGY, 2014, 65 :91-100
[32]  
Stene J, 2008, 8 IIR G LOR C NAT WO
[33]  
Thumann A., 2008, HDB ENERGY ENG, Veighth, P2021
[34]   LCA of renewable energy for electricity generation systems-A review [J].
Varun ;
Bhat, I. K. ;
Prakash, Ravi .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (05) :1067-1073
[35]   Investigation of the performance of a high-temperature heat pump using parallel cycles with serial heating on the water side [J].
Wang, Kai ;
Cao, Feng ;
Wang, Shouguo ;
Xing, Ziwen .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (06) :1142-1151
[36]   Scroll compressors using gas and liquid injection: experimental analysis and modelling [J].
Winandy, EL ;
Lebrun, J .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (08) :1143-1156
[37]  
Wolf S., 2012, ECEEE 2012 SUMMER ST
[38]   Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures [J].
Zhang, Shengjun ;
Wang, Huaixin ;
Guo, Tao .
APPLIED ENERGY, 2010, 87 (05) :1554-1561