THE EFFECT OF HENNA PASTE ON OXYGEN-SATURATION READING OBTAINED BY PULSE OXIMETRY

被引:0
作者
ALMAJED, SA [1 ]
HARAKATI, MS [1 ]
机构
[1] KING SAUD UNIV, KING KHALID UNIV HOSP, COLL MED, DEPT MED 38, RIYADH 11472, SAUDI ARABIA
来源
TROPICAL AND GEOGRAPHICAL MEDICINE | 1994年 / 46卷 / 01期
关键词
HENNA; PULSE OXIMETRY; OXYGEN SATURATION; SAUDI ARABIA;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A controlled study was designed to examine the effect of red and black henna on the measurement of oxygen saturation by pulse oximetry. Fifty adult normal female volunteers had their left thumb coloured with red henna (40) or black henna (10). The uncoloured right thumb was used as a control. All measurements were done under room temperature, and the same pulse oximeter was used in ah volunteers. In the red henna group there was no difference on oximetry reading between right and left thumb. In contrast, the thumb coloured with black henna gave no reading when compared to the uncoloured right thumb, On the basis of this study, pulse oximetry is not limited by red henna while black henna has a potential of causing major error in the measurement of oxygen saturation by pulse oximetry, In these cases we recommend to use ear oximetry for accurate measurement of oxygen saturation.
引用
收藏
页码:38 / 39
页数:2
相关论文
共 50 条
  • [21] Low signal quality pulse oximetry measurements in newborn infants are reliable for oxygen saturation but underestimate heart rate
    Narayen, Ilona C.
    Smit, Marrit
    van Zwet, Erik W.
    Dawson, Jennifer A.
    Blom, Nico A.
    te Pas, Arjan B.
    ACTA PAEDIATRICA, 2015, 104 (04) : E158 - E163
  • [22] Pattern Analysis of Oxygen Saturation Variability in Healthy Individuals: Entropy of Pulse Oximetry Signals Carries Information about Mean Oxygen Saturation
    Bhogal, Amar S.
    Mani, Ali R.
    FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [23] Doppler ultrasonographic evidence of intrapartum brain-sparing effect in fetuses with low oxygen saturation according to pulse oximetry
    Sütterlin, MW
    Seelbach-Göbel, B
    Oehler, MK
    Heupel, M
    Dietl, J
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1999, 181 (01) : 216 - 220
  • [24] Low oxygen saturation by pulse oximetry may be associated with a low oxygen affinity hemoglobin variant, hemoglobin titusville
    Deyell, R
    Jackson, S
    Spier, S
    Le, D
    Poon, MC
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2006, 28 (02) : 100 - 102
  • [25] Rate of decline in oxygen saturation at various pulse oximetry values with prehospital rapid sequence intubation
    Davis, Daniel P.
    Hwang, James Q.
    Dunford, James V.
    PREHOSPITAL EMERGENCY CARE, 2008, 12 (01) : 46 - 51
  • [26] Discrepancy between arterial oxygen saturation and pulse oximetry measurement in a Chinese pediatric patient cohort
    Chen, Qin-chang
    Shen, Jun-jun
    Huang, Yu-lu
    Kong, Ran
    Xie, Yu-mei
    Wang, Shu- shui
    HELIYON, 2024, 10 (07)
  • [27] Quantifying Blood-Oxygen Saturation Measurement Error in Motion Contaminated Pulse Oximetry Signals
    Clarke, G. W. J.
    Chan, A. D. C.
    Adler, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 986 - 989
  • [28] Comparison of human smartwatch and transmittance pulse oximetry for evaluating peripheral oxygen saturation in anesthetized dogs
    Senocak, M. G.
    Okur, S.
    Ersoz, U.
    Yanmaz, L. E.
    Kocaman, Y.
    Turgut, F.
    Bedir, A. G.
    Orhun, O. T.
    IRANIAN JOURNAL OF VETERINARY RESEARCH, 2024, 25 (02) : 166 - 169
  • [29] EFFECT OF INTRAOPERATIVE INSPIRED GAS-MIXTURES ON POSTOPERATIVE NOCTURNAL OXYGEN-SATURATION
    ROBERTS, CJ
    PARKE, TJ
    SYKES, MK
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (04) : 476 - 480
  • [30] Accuracy of pulse oximetry in preterm and term infants is insufficient to determine arterial oxygen saturation and tension
    Wackernagel, Dirk
    Blennow, Mats
    Hellstrom, Ann
    ACTA PAEDIATRICA, 2020, 109 (11) : 2251 - 2257