RELIABILITY OF A CLINICAL KINEMATIC ASSESSMENT OF THE SIT-TO-STAND MOVEMENT

被引:30
|
作者
JENG, SF
SCHENKMAN, M
ORILEY, P
LIN, SJ
机构
[1] MASSACHUSETTS GEN HOSP,INST HLTH PROFESS,BOSTON,MA 02108
[2] BOSTON UNIV,SARGENT COLL ALLIED HLTH PROFESS,DEPT PHYS THERAPY,BOSTON,MA 02215
[3] MASS GEN HOSP,BIOMOT LAB,BOSTON,MA 02114
[4] LAWRENCE MEM HOSP MEDFORD,MEDFORD,MA 02155
来源
PHYSICAL THERAPY | 1990年 / 70卷 / 08期
关键词
Functional movement; Kinesiology/biomechanics; sit-to-stand analysis; Tests and measurements; functional;
D O I
10.1093/ptj/70.8.511
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined the reproducibility of a kinematic assessment of the sit-to-stand movement in 15 healthy subjects using a standardized protocol. We examined the within-rater and between-rater reliability of the assessment using a clinically feasible method, the video-goniometric measurement method, to analyze the task. Two variables were measured to characterize the sit-to-stand movement: 1) joint angles for four body segments (head, trunk, knee, and ankle) and 2) three events (maximal trunk flexion, lift-off, and maximal trunk extension). High reproducibility was found for all joint angles, except for the head angle. Both within-rater and between-rater goniometric measurements were highly reliable (ICC > .80). Identification of the events was reproducible within raters and between different raters. We conclude that this method can lead to reliable assessments of a healthy population. The reliability data established in this study can be used to help clinicians determine the impairments of patients.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 50 条
  • [31] Optimum position and orientation of handrail for sit-to-stand movement
    Chihara, Takanori
    Fukuchi, Naoko
    Seo, Akihiko
    JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2015, 9 (03):
  • [32] A Comparison of Four Approaches to Evaluate the Sit-to-Stand Movement
    Shukla, Brajesh K.
    Jain, Hiteshi
    Vijay, Vivek
    Yadav, Sandeep K.
    Mathur, Arvind
    Hewson, David J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (06) : 1317 - 1324
  • [33] Readiness potential reflects the intention of sit-to-stand movement
    Balbir Singh
    Kiyohisa Natsume
    Cognitive Neurodynamics, 2023, 17 : 605 - 620
  • [34] Validity of accelerometry in assessing the duration of the sit-to-stand movement
    Wim G. M. Janssen
    Johannes B. J. Bussmann
    Herwin L. D. Horemans
    Henk J. Stam
    Medical & Biological Engineering & Computing, 2008, 46 : 879 - 887
  • [35] Readiness potential reflects the intention of sit-to-stand movement
    Singh, Balbir
    Natsume, Kiyohisa
    COGNITIVE NEURODYNAMICS, 2023, 17 (03) : 605 - 620
  • [36] INVERSE DYNAMIC ROBUST CONTROL OF SIT-TO-STAND MOVEMENT
    Nematollahi, Mohammad Hassan
    Haghpanah, Seyyed Arash
    Taghvaei, Sajjad
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2019, 31 (06):
  • [37] Spinopelvic movement strategies during sit-to-stand and stand-to-sit in adult spinal deformity
    Severijns, Pieter
    Overbergh, Thomas
    Desloovere, Kaat
    Moke, Lieven
    Scheys, Lennart
    GAIT & POSTURE, 2022, 92 : 15 - 23
  • [38] Comparison of Kinematic Movement Patterns Between 2 Subgroups of Females With Low Back Pain and Healthy Women During Sit-to-Stand and Stand-to-Sit
    Orakifar, Neda
    Shaterzadeh-Yazdi, Mohammad Jafar
    Salehi, Reza
    Mehravar, Mohammad
    Namnik, Neda
    Haghpanah, Seyyed Arash
    JOURNAL OF APPLIED BIOMECHANICS, 2022, 38 (05) : 346 - 354
  • [39] Reliability and validity of a smartphone-based application for the quantification of the sit-to-stand movement in healthy seniors
    Cerrito, Adrien
    Bichsel, Lukas
    Radlinger, Lorenz
    Schmid, Stefan
    GAIT & POSTURE, 2015, 41 (02) : 409 - 413
  • [40] A new integrated kinematic sensor for the classification of sit-to-stand locomotion task
    Costantini, Giovanni
    Carota, Massimo
    Maccioni, Giovanni
    Giansanti, Daniele
    2007 2ND INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACE, 2007, : 21 - +