PIN DIODE FOR REAL-TIME DOSIMETRY IN A MIXED FIELD OF NEUTRONS AND GAMMA-RAYS

被引:12
|
作者
MATSUMOTO, T
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a080949
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dose equivalent of neutrons and gamma rays in a mixed field was measured with a single small PIN diode implanted with boron atoms. The pulse height of the signals was discriminated against thermal, fast neutrons and gamma rays. The sensitivities corresponding to 1 cps of the detector in the mixed field were found to be 130-mu-Sv.h-1 and 280-mu-Sv.h-1 for photons and thermal neutrons, respectively. The directional dependence in free air irradiation for photons was almost isotropic with angle of incidence while the response for neutrons fell above an incident angle of 45-degrees. The energy response to neutrons was measured as a function of polyethylene thickness. The results obtained using a 4 cm thickness were in good agreement with the ICRP dose equivalent values for thermal, 144 keV and fast neutrons.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 50 条
  • [1] NATURAL FLUORITE IN DOSIMETRY OF MIXED FIELD OF GAMMA-RAYS AND THERMAL-NEUTRONS
    MISHEV, IT
    RADICHEVA, MA
    LEVI, SM
    HEALTH PHYSICS, 1972, 23 (03): : 367 - +
  • [2] DOSIMETRY SYSTEM FOR NEUTRONS AND GAMMA-RAYS
    TUMBRAGEL, GE
    NIEMANN, K
    EYL, HJ
    HOEGL, AJ
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 141 - 143
  • [3] OER FOR MIXED NEUTRONS AND GAMMA-RAYS
    KATZ, R
    SHARMA, SC
    BRITISH JOURNAL OF RADIOLOGY, 1974, 47 (563): : 823 - 823
  • [4] CHEMICAL DOSIMETER FOR NEUTRONS AND GAMMA-RAYS FOR PERSONNEL ACCIDENTAL DOSIMETRY
    DVORNIK, I
    ZEC, U
    ZIVADINOVIC, M
    RAZEM, D
    MISCEVIC, S
    HEALTH PHYSICS, 1976, 31 (03): : 276 - 276
  • [5] Quick algorithms for real-time discrimination of neutrons and gamma rays
    Amiri, Moslem
    Prenosil, Vaclav
    Cvachovec, Frantisek
    Matej, Zdenek
    Mravec, Filip
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (01) : 583 - 599
  • [6] Quick algorithms for real-time discrimination of neutrons and gamma rays
    Moslem Amiri
    Václav Přenosil
    František Cvachovec
    Zdeněk Matěj
    Filip Mravec
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 583 - 599
  • [7] DEPTH DOSE DISTRIBUTION IN A BEAGLE PHANTOM WITHIN A MIXED FIELD OF NEUTRONS AND GAMMA-RAYS
    SIMPSON, RE
    SAYEG, JA
    LUCAS, AC
    HEALTH PHYSICS, 1966, 12 (12): : 1793 - +
  • [8] The production of gamma-rays by neutrons
    Burhop, EHS
    Hill, RD
    Townsend, AA
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1938, 165 (A920) : 0116 - 0132
  • [9] USABILITY OF TRACK DETECTORS IN MIXED FIELDS OF NEUTRONS AND GAMMA-RAYS
    GOMAA, MA
    ELKOLALY, MA
    NUCLEAR INSTRUMENTS & METHODS, 1976, 134 (02): : 253 - 255
  • [10] Study of silicon PIN diode responses to low energy gamma-rays
    Lee, S. C.
    Jeon, H. B.
    Kang, K. H.
    Park, H.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (10) : 1587 - 1590