HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR BASIC AMINE DRUGS IN HUMAN PLASMA WITH A SILICA-GEL COLUMN AND AN AQUEOUS MOBILE PHASE .4. ALBUTEROL

被引:7
作者
WU, YQ [1 ]
SHI, R [1 ]
WILLIAMS, RL [1 ]
LIN, ET [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,SCH PHARM,DEPT PHARM,SAN FRANCISCO,CA 94143
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1991年 / 14卷 / 02期
关键词
D O I
10.1080/01483919108049612
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high performance liquid chromatographic (HPLC) assay is presented for the determination of albuterol in human plasma. Sample analysis is performed with a silica gel column and an aqueous mobile phase. Plasma samples are extracted with chloroform containing di(2-ethylhexyl) phosphate. Samples are back extracted into a hydrochloric acid solution. A fluorescence detector is used for this assay. The detection limit of the assay is 0.2 ng/ml for 0.5 ml plasma samples. This method has been used in a bioavailability study of albuterol sulfate tablets (4.8 mg) given to healthy volunteers.
引用
收藏
页码:253 / 264
页数:12
相关论文
共 13 条
[1]   SEPARATION OF ORGANIC AMINE COMPOUNDS ON SILICA-GEL WITH REVERSED-PHASE ELUENTS [J].
BIDLINGMEYER, BA ;
DELRIOS, JK ;
KORPI, J .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :442-447
[2]   DETERMINATION OF SALBUTAMOL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
HUTCHINGS, MJ ;
PAULL, JD ;
MORGAN, DJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 277 (OCT) :423-426
[3]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF SALBUTAMOL IN RABBIT PLASMA [J].
KUROSAWA, N ;
MORISHIMA, S ;
OWADA, E ;
ITO, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 305 (02) :485-488
[4]  
LEFERRINK JD, 1987, J CHROMATOGR, V229, P217
[5]  
LOO JCK, 1987, RES COMMUN CHEM PATH, V55, P283
[6]   DETERMINATION OF ALBUTEROL IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
MILLER, LG ;
GREENBLATT, DJ .
JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01) :205-208
[7]   ANALYSIS OF ALBUTEROL IN HUMAN-PLASMA BASED ON IMMUNOAFFINITY CHROMATOGRAPHIC CLEANUP COMBINED WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORIMETRIC DETECTION [J].
ONG, H ;
ADAM, A ;
PERREAULT, S ;
MARLEAU, S ;
BELLEMARE, M ;
DUSOUICH, P ;
BEAULIEU, N .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 :213-221
[8]   DETERMINATION OF SALBUTAMOL IN HUMAN-PLASMA WITH BIMODAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND A ROTATED DISK AMPEROMETRIC DETECTOR [J].
OOSTERHUIS, B ;
VANBOXTEL, CJ .
JOURNAL OF CHROMATOGRAPHY, 1982, 232 (02) :327-334
[9]   COMPARATIVE BIOAVAILABILITY AND PHARMACOKINETICS OF 3 FORMULATIONS OF ALBUTEROL [J].
POWELL, ML ;
WEISBERGER, M ;
GURAL, R ;
CHUNG, M ;
PATRICK, JE ;
RADWANSKI, E ;
SYMCHOWICZ, SS .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1985, 74 (02) :217-219
[10]  
SHI RJY, 1987, ANAL LETT, V20, P131