SODIUM CORROSION AND MASS-TRANSFER ANALYSIS WITH AN ION PROBE MASS-SPECTROMETER

被引:4
作者
BERKEY, E
SWEENEY, GG
HICKAM, WM
机构
关键词
ION PROBE MASS SPECTROMETRY;
D O I
10.13182/NT72-A31192
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The initial application of ion probe mass spectrometry, a new analytical technique, to the characterization of samples from an experimental sodium mass transfer loop has been made. The technique is capable of performing multielement analyses from hydrogen to uranium at parts per million sensitivities with a spatial resolution of 1 mu m. Analyses of hot leg samples from a 10 000 h/low oxygen loop reveal significant concentration changes over the depleted zone and confirm extensive loss of carbon. Analyses of cold leg deposits from the same loop show the presence of occluded metallic sodium and a small component of oxides, in addition to numerous other constituents. Concentration profiles in the deposits indicate that they are both nitrided and carburized with a major oxide layer in the interface between the deposits and the stainless-steel substrate.
引用
收藏
页码:263 / &
相关论文
共 19 条
[11]  
ROY P, 1968, 1968 P INT C SOD TEC
[12]  
SCHROCK SL, 1970, CORROSION LIQUID MET
[13]  
SHIELS SA, 1972, CHEMICAL ASPECTS COR
[14]   ANALYSIS OF SURFACES UTILIZING SPUTTER ION SOURCE INSTRUMENTS [J].
SOCHA, AJ .
SURFACE SCIENCE, 1971, 25 (01) :147-&
[15]   LASER MICROPROBE APPLIED TO INVESTIGATION OF SODIUM PENETRATION INTO STAINLESS STEEL [J].
SOWA, ES .
NUCLEAR APPLICATIONS, 1969, 7 (01) :100-&
[16]  
Tyzack C, 1967, CORROSION BEHAV STEE
[17]  
WHITLOW GA, 1972, CHEMICAL ASPECTS COR
[18]  
1967, 1966 P S ALK MET COO
[19]  
1968, ANL7520 1