A ROTATING PET SCANNER USING BGO BLOCK DETECTORS - DESIGN, PERFORMANCE AND APPLICATIONS

被引:0
作者
TOWNSEND, DW
WENSVEEN, M
BYARS, LG
GEISSBUHLER, A
TOCHONDANGUY, HJ
CHRISTIN, A
DEFRISE, M
BAILEY, DL
GROOTOONK, S
DONATH, A
NUTT, R
机构
[1] UNIV GENEVA,HOP CANTONAL,DIV NUCL MED,CH-1211 GENEVA 4,SWITZERLAND
[2] VRIJE UNIV BRUSSELS,DIV NUCL MED,B-1050 BRUSSELS,BELGIUM
[3] CTI SIEMENS PET SYST,KNOXVILLE,TN
[4] ROYAL PRINCE ALFRED HOSP,DIV NUCL MED,SYDNEY,AUSTRALIA
[5] HAMMERSMITH HOSP,MRC,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in fully three-dimensional reconstruction for multi-ring PET scanners have led us to explore the potential of a prototype scanner based on the rotation of two opposing arrays of BGO block detectors. The prototype contains only one-third of the number of detectors in the equivalent full ring scanner, resulting in reduced cost. With a lower energy threshold at 250 keV, the absolute efficiency of the scanner is 0.5% and the scatter fraction is 35% for a 20-cm cylinder. Transaxial and axial spatial resolution is about 6 mm. The maximum noise equivalent count rate estimated for a 15-cm diameter cylinder is 36,000 cps at a concentration of 26 kBq/ml. The minimum scan time for a F-18-fluoro-2-deoxyglucose (FDG) brain study is 55 sec. The camera has been validated for clinical applications using both FDG and Rb-82.
引用
收藏
页码:1367 / 1376
页数:10
相关论文
共 24 条
  • [11] THE PERFORMANCE OF A MULTIWIRE PROPORTIONAL CHAMBER POSITRON CAMERA FOR CLINICAL USE
    MARSDEN, PK
    OTT, RJ
    BATEMAN, JE
    CHERRY, SR
    FLOWER, MA
    WEBB, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (08) : 1043 - 1062
  • [12] DATA ACQUISITION FOR A MEDICAL IMAGING MWPC DETECTOR
    MCKEE, BTA
    HARVEY, PJ
    MACPHAIL, JD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) : 545 - 551
  • [13] MUEHLLEHNER G, 1977, MED RADIONUCLIDE IMA, V1, P291
  • [14] CLINICAL PET WITH A LARGE AREA MULTIWIRE PROPORTIONAL CHAMBER PET CAMERA
    OTT, RJ
    MARSDEN, PK
    FLOWER, MA
    WEBB, S
    CHERRY, S
    MCCREADY, VR
    BATEMAN, JE
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (02) : 436 - 442
  • [15] PAANS AMJ, 1985, J NUCL MED, V26, P1466
  • [16] PELC NJ, 1979, THESIS HARVARD SCH P, P140
  • [17] TOMOGRAPHIC MEASUREMENT OF LOCAL CEREBRAL GLUCOSE METABOLIC-RATE IN HUMANS WITH (F-18)2-FLUORO-2-DEOXY-D-GLUCOSE - VALIDATION OF METHOD
    PHELPS, ME
    HUANG, SC
    HOFFMAN, EJ
    SELIN, C
    SOKOLOFF, L
    KUHL, DE
    [J]. ANNALS OF NEUROLOGY, 1979, 6 (05) : 371 - 388
  • [18] SCHORR B, 1983, PHYS MED BIOL, V28, P305
  • [19] PHYSICAL PERFORMANCE OF A POSITRON TOMOGRAPH FOR BRAIN IMAGING WITH RETRACTABLE SEPTA
    SPINKS, TJ
    JONES, T
    BAILEY, DL
    TOWNSEND, DW
    GROOTOONK, S
    BLOOMFIELD, PM
    GILARDI, MC
    CASEY, ME
    SIPE, B
    REED, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (08) : 1637 - 1655
  • [20] A PROTOTYPE BAF2/TMAE LOW-PRESSURE MULTIWIRE PROPORTIONAL CHAMBER FOR PET
    SUCKLING, J
    OTT, RJ
    MARSDEN, PK
    BATEMAN, JE
    CONNOLLY, JF
    STEPHENSON, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 703 - 708