MAGNETIC-RESONANCE-IMAGING AND PULSED DOPPLER SONOGRAPHY OF POSTSTENOTIC JETS - CORRELATION BETWEEN SIGNAL VOID AND FLOW VELOCITY DISTRIBUTION

被引:6
|
作者
SPIELMANN, RP
ZHEN, J
TRIEBEL, HJ
NICOLAS, V
HELLER, M
BUCHELER, E
机构
[1] Department of Diagnostic Radiology, Eppendorf University Hospital, Hamburg
关键词
MAGNETIC RESONANCE IMAGING; DOPPLER SONOGRAPHY; FLOW; STENOSIS; TURBULENCE;
D O I
10.1016/0730-725X(92)90443-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To correlate the appearance of poststenotic jets on gradient echo images with features of localized Doppler spectra of the jets, we studied an in vitro model of steady flow-through stenoses of 86, 96, and 99% area reduction. As fluids, water and a 400% glycerol solution in water were used. MRI was performed with a 1.5 T whole body imager and gradient echo images were obtained in planes parallel to the direction of flow. Doppler spectra were acquired separately from the MR measurements at 1 cm intervals for a distance of 10 cm downstream from the stenosis. Poststenotic signal void was observed for water and for the 40% glycerol solution only if the mean velocity within the stenosis exceeded a limit of 50-60 cm/sec. On the MR images, the jets could be divided into two segments: A proximal jet segment of uniform width equal to the diameter of the stenosis, followed by a distal jet segment which was characterized by broadening and then dissipating signal void. Except for the 99% stenosis, a high signal intensity core was present within the proximal jet segment. In the proximal jet segment, the Doppler measurements showed a low temporal fluctuation of the maximal flow velocity and only little flow opposite to the main flow direction. In the distal jet segment, the velocity fluctuation and the intensity of reverse flow increased sharply. The high signal intensity core of the jet was associated with a poststenotic zone of constant maximal flow velocity. The results demonstrate a close relationship between characteristic features of poststenotic jets in MRI and pulsed Doppler sonography.
引用
收藏
页码:893 / 901
页数:9
相关论文
共 21 条
  • [1] Brain Blood Flow and Velocity Correlations Between Magnetic Resonance Imaging and Transcranial Doppler Sonography
    Sorond, Farzaneh A.
    Hollenberg, Norman K.
    Panych, Lawrence P.
    Fisher, Naomi D. L.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (07) : 1017 - 1022
  • [2] IMPACT OF VESSEL DISTORTION ON TRANSCRANIAL DOPPLER VELOCITY-MEASUREMENTS - CORRELATION WITH MAGNETIC-RESONANCE-IMAGING
    FINN, JP
    QUINN, MW
    HALLCRAGGS, MA
    KENDALL, BE
    JOURNAL OF NEUROSURGERY, 1990, 73 (04) : 572 - 575
  • [3] WHICH DISK AS VISUALIZED BY MAGNETIC-RESONANCE-IMAGING IS ACTUALLY A SOURCE OF PAIN - A CORRELATION BETWEEN MAGNETIC-RESONANCE-IMAGING AND DISCOGRAPHY
    HORTON, WC
    DAFTARI, TK
    SPINE, 1992, 17 (06) : S164 - S171
  • [4] CORRELATION BETWEEN COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING IN DIASTEMATOMYELIA
    OZEK, MM
    PAMIR, MN
    OZER, AF
    KELES, GE
    ERZEN, C
    EUROPEAN JOURNAL OF RADIOLOGY, 1991, 13 (03) : 209 - 214
  • [5] In vitro agreement between magnetic resonance imaging and intraluminal Doppler ultrasound for high flow velocity measurements
    Matre, K
    Ersland, L
    Larsen, TH
    Andersen, E
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2002, 36 (03) : 180 - 186
  • [6] CORRELATION BETWEEN COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING IN GRAVES ORBITOPATHY
    NIANIARIS, N
    HURWITZ, JJ
    CHEN, JC
    WORTZMAN, G
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1994, 29 (01): : 9 - 12
  • [7] High-flow priapism due to cavernous artery pseudoaneurysm: color Doppler sonography and magnetic resonance imaging findings
    Engin, G
    Tunaci, M
    Acunas, B
    EUROPEAN RADIOLOGY, 1999, 9 (08) : 1698 - 1699
  • [8] High-flow priapism due to cavernous artery pseudoaneurysm: color Doppler sonography and magnetic resonance imaging findings
    Gülgün Engin
    Mehtap Tunaci
    Bülent Acunaş
    European Radiology, 1999, 9 : 1698 - 1699
  • [9] HISTOPATHOLOGIC CORRELATION OF MAGNETIC-RESONANCE-IMAGING SIGNAL PATTERNS IN A SPINAL-CORD INJURY MODEL
    WEIRICH, SD
    COTLER, HB
    NARAYANA, PA
    HAZLE, JD
    JACKSON, EF
    COUPE, KJ
    MCDONALD, CL
    LANGFORD, LA
    HARRIS, JH
    SPINE, 1990, 15 (07) : 630 - 638
  • [10] THE CORRELATION BETWEEN MAGNETIC-RESONANCE-IMAGING AND ULTRASTRUCTURAL PATTERNS OF BROWN ADIPOSE-TISSUE
    OSCULATI, F
    SBARBATI, A
    LECLERCQ, F
    ZANCANARO, C
    ACCORDINI, C
    ANTONAKIS, K
    BOICELLI, A
    CINTI, S
    JOURNAL OF SUBMICROSCOPIC CYTOLOGY AND PATHOLOGY, 1991, 23 (01) : 167 - 174