2-PHASE LIQUID-LIQUID-EXTRACTION IN MONOSEGMENTED FLOW-ANALYSIS - DETERMINATION OF CADMIUM WITH 1-(2'-PYRIDYLAZO)NAPHTHOL

被引:34
作者
FACCHIN, I [1 ]
PASQUINI, C [1 ]
机构
[1] UNIV ESTADUAL CAMPINAS,INST QUIM,BR-13083970 CAMPINAS,BRAZIL
关键词
FLOW SYSTEM; LIQUID-LIQUID EXTRACTION; CADMIUM;
D O I
10.1016/0003-2670(94)00563-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A monosegmented flow system has been developed to perform liquid-liquid extraction. Monosegmented samples are introduced in a glass tube between two air bubbles. The volume of organic phase, containing an extracting reagent, is added after the second bubble by switching on a solenoid valve using an optical sensor and a timer circuit. It was observed that the transference of the analyte from the aqueous to the organic phase is achieved by adsorption on the surface of the tube followed by desorption into the organic phase. The system was evaluated for Cd(II) extraction at pH 9.9, employing chloroform-1-(2'-pyridylazo)naphthol as organic phase. The extraction efficiency is 75% and can be improved to be near 100% if the direction of the carrier flow is changed for a number of cycles in the same injection. Spectrophotometric detection was made without phase isolation at the end of the extraction tube. The detection limit (signal-to-blank = 3) for Cd(II) is 85 ng l(-1) and a linear calibration graph was obtained for concentrations of the metal up to 2.0 mg l(-1). Samples can be introduced in the system at 30 h(-1). Other metals such as Cu(II) and Zn(II) can be also extracted employing the proposed methodology.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 14 条
[1]   AUTOMATED GRAVIMETRIC MANAGEMENT OF SOLUTIONS .1. HIGH-PERFORMANCE MICROCOMPUTER-CONTROLLED GRAVIMETRIC BURET [J].
CUNHA, IBS ;
PASQUINI, C .
ANALYST, 1992, 117 (05) :905-911
[2]   SOLVENT-EXTRACTION IN CONTINUOUS-FLOW SYSTEMS WITH INTELLIGENT ZONE SAMPLING [J].
DASGUPTA, PK ;
LEI, W .
ANALYTICA CHIMICA ACTA, 1989, 226 (02) :255-269
[3]   SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANTS USING MONOSEGMENTED CONTINUOUS-FLOW ANALYSIS [J].
DEANDRADE, JC ;
FERREIRA, M ;
BACCAN, N ;
BATAGLIA, OC .
ANALYST, 1988, 113 (02) :289-293
[4]   SPECTROPHOTOMETRIC DETERMINATION OF CREATININE BY MONOSEGMENTED CONTINUOUS-FLOW ANALYSIS [J].
DEFARIA, LC ;
PASQUINI, C .
JOURNAL OF AUTOMATIC CHEMISTRY, 1992, 14 (03) :97-100
[5]   SINGLE-PHASE LIQUID-LIQUID-EXTRACTION IN MONOSEGMENTED CONTINUOUS-FLOW SYSTEMS [J].
FACCHIN, I ;
MARTINS, JW ;
ZAMORA, PGP ;
PASQUINI, C .
ANALYTICA CHIMICA ACTA, 1994, 285 (03) :287-292
[6]   LIQUID-LIQUID-EXTRACTION FLOW-INJECTION ANALYSIS [J].
KUBAN, V .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1991, 22 (06) :477-557
[7]   FLOW-INJECTION AND SOLVENT-EXTRACTION WITH INTELLIGENT SEGMENT SEPARATION - DETERMINATION OF QUATERNARY AMMONIUM-IONS BY ION-PAIRING [J].
LINDGREN, CC ;
DASGUPTA, PK .
TALANTA, 1992, 39 (02) :101-111
[8]   DIRECT AUTOMATIC-DETERMINATION OF POLYPHENOLS IN OLIVE OILS IN THE AQUEOUS PHASE OF A FLOW-INJECTION LIQUID-LIQUID-EXTRACTION SYSTEM WITHOUT PHASE-SEPARATION [J].
MESA, JAG ;
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1990, 235 (02) :441-444
[10]   MONOSEGMENTED SYSTEM FOR CONTINUOUS-FLOW ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF CHROMIUM(VI), AMMONIA, AND PHOSPHORUS [J].
PASQUINI, C ;
DEOLIVEIRA, WA .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2575-2579