EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM

被引:65
作者
DIMICH, I
SINGH, PP
ADELL, A
HENDLER, M
SONNENKLAR, N
JHAVERI, M
机构
[1] MT SINAI MED SCH,DEPT ANESTHESIOL,NEW YORK,NY
[2] CITY HOSP CTR,ELMHURST,NY 11373
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1991年 / 38卷 / 08期
关键词
ANESTHESIA; -; OBSTETRICAL; NEONATES; MEASUREMENT TECHNIQUES - OXIMETERS; MONITORING; OXYGEN; OXYGEN - BLOOD LEVELS; MEASUREMENT;
D O I
10.1007/BF03008616
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.
引用
收藏
页码:985 / 988
页数:4
相关论文
共 37 条
  • [31] MONITORING OF MIXED VENOUS OXYGEN-SATURATION AND PRESSURE FROM BIOSENSORS IN THE RIGHT VENTRICLE - A 24-HOUR STUDY IN PATIENTS WITH HEART-FAILURE
    OHLSSON, A
    BECK, R
    BENNETT, T
    NORDLANDER, R
    RYDEN, J
    ASTROM, H
    RYDEN, L
    EUROPEAN HEART JOURNAL, 1995, 16 (09) : 1215 - 1222
  • [32] NEAR-PATIENT MEASUREMENTS OF METHEMOGLOBIN, OXYGEN-SATURATION, AND TOTAL HEMOGLOBIN - EVALUATION OF A NEW INSTRUMENT FOR ADULT AND NEONATAL INTENSIVE-CARE
    GONG, AK
    CRITICAL CARE MEDICINE, 1995, 23 (01) : 193 - 201
  • [33] Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves
    Kanz, P.
    Krieger, S.
    Drillich, M.
    Iwersen, M.
    JOURNAL OF DAIRY SCIENCE, 2018, 101 (07) : 6437 - 6442
  • [34] DISSOLVED OXYGEN MONITORING SYSTEM USING A PULSED ELECTRODE: DESIGN, PERFORMANCE, AND EVALUATION.
    Langdon, Christopher
    Deep-Sea Research, Part A: Oceanographic Research Papers, 1984, 31 (11 A Pt A): : 1357 - 1367
  • [35] Remote Health Monitoring System for the Estimation of Blood Pressure, Heart Rate, and Blood Oxygen Saturation Level
    Nwibor, Chike
    Haxha, Shyqyri
    Ali, Mian Mujtaba
    Sakel, Mohamed
    Haxha, Anda Rexha
    Saunders, Karen
    Nabakooza, Shakira
    IEEE SENSORS JOURNAL, 2023, 23 (05) : 5401 - 5411
  • [36] Pulsoximetric monitoring of fetal arterial oxygen saturation and fetal pulse at stage II of labor to predict acidosis in newborn Holstein Friesian calves
    Kanz, P.
    Gusterer, E.
    Krieger, S.
    Schweinzer, V.
    Suess, D.
    Drillich, M.
    Iwersen, M.
    THERIOGENOLOGY, 2020, 142 : 303 - 309
  • [37] Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
    Biancofiore, G.
    Critchley, L. A. H.
    Lee, A.
    Bindi, L.
    Bisa, M.
    Esposito, M.
    Meacci, L.
    Mozzo, R.
    DeSimone, P.
    Urbani, L.
    Filipponi, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) : 47 - 54