EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM

被引:65
|
作者
DIMICH, I
SINGH, PP
ADELL, A
HENDLER, M
SONNENKLAR, N
JHAVERI, M
机构
[1] MT SINAI MED SCH,DEPT ANESTHESIOL,NEW YORK,NY
[2] CITY HOSP CTR,ELMHURST,NY 11373
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1991年 / 38卷 / 08期
关键词
ANESTHESIA; -; OBSTETRICAL; NEONATES; MEASUREMENT TECHNIQUES - OXIMETERS; MONITORING; OXYGEN; OXYGEN - BLOOD LEVELS; MEASUREMENT;
D O I
10.1007/BF03008616
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.
引用
收藏
页码:985 / 988
页数:4
相关论文
共 37 条
  • [21] END-TIDAL OXYGEN CONCENTRATION AND PULSE OXIMETRY FOR MONITORING OXYGENATION DURING INTRATRACHEAL JET VENTILATION
    BAER, GA
    PALOHEIMO, M
    RAHNASTO, J
    PUKANDER, J
    JOURNAL OF CLINICAL MONITORING, 1995, 11 (06): : 373 - 380
  • [22] EXAMINATION OF CARDIORESPIRATORY CHANGES DURING UPPER GASTROINTESTINAL ENDOSCOPY - COMPARISON OF MONITORING OF ARTERIAL OXYGEN-SATURATION, ARTERIAL-PRESSURE AND THE ELECTROCARDIOGRAM
    MURRAY, AW
    MORRAN, CG
    KENNY, GNC
    MACFARLANE, P
    ANDERSON, JR
    ANAESTHESIA, 1991, 46 (03) : 181 - 184
  • [23] Design and Implementation of an OCC-Based Real-Time Heart Rate and Pulse-Oxygen Saturation Monitoring System
    Ahmed, Md. Faisal
    Hasan, Moh. Khalid
    Shahjalal, Md.
    Alam, Md. Morshed
    Jang, Yeong Min
    IEEE ACCESS, 2020, 8 : 198740 - 198747
  • [24] Can the blood content of the tissues be determined optically during pulse oximetry without knowledge of the oxygen saturation? An in-vitro investigation
    Edrich, T
    Knitza, R
    Rall, G
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 3072 - 3075
  • [25] A Smart Phone Healthcare Monitoring System for Oxygen Saturation and Heart Rate
    Fang, Dongjian
    Hu, Jicheng
    Wei, Xiaofeng
    Shao, Heng
    Luo, Yongen
    2014 INTERNATIONAL CONFERENCE ON CYBER-ENABLED DISTRIBUTED COMPUTING AND KNOWLEDGE DISCOVERY (CYBERC), 2014, : 245 - 247
  • [26] Peripheral Oxygen Saturation Levels: A Comparative Assessment among Different Fingers and between the 2 Most Commonly Used Pulse Oximetry Systems
    Govindarajan, Shruti
    Hegde, Usha
    Nitin, Priyanka
    Sreeshyla, Huchanahalli Sheshanna
    Rajashekaraiah, Premalatha Bidadi
    BIOMEDICAL AND BIOTECHNOLOGY RESEARCH JOURNAL, 2023, 7 (03): : 371 - 376
  • [27] Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury
    Souter, MJ
    Andrews, PJD
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (05) : 744 - 746
  • [28] Assessment of oxygen saturation in retinal vessels of normal subjects and diabetic patients with and without retinopathy using Flow Oximetry System
    Ibrahim, Mohamed A.
    Annam, Rachel E.
    Sepah, Yasir J.
    Luu, Long
    Bittencourt, Millena G.
    Jang, Hyun S.
    Lemaillet, Paul
    Munoz, Beatriz
    Duncan, Donald D.
    West, Sheila
    Nguyen, Quan Dong
    Ramella-Roman, Jessica C.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2015, 5 (01) : 86 - 96
  • [29] MONITORING OF MIXED VENOUS OXYGEN-SATURATION AND PRESSURE FROM BIOSENSORS IN THE RIGHT VENTRICLE - A 24-HOUR STUDY IN PATIENTS WITH HEART-FAILURE
    OHLSSON, A
    BECK, R
    BENNETT, T
    NORDLANDER, R
    RYDEN, J
    ASTROM, H
    RYDEN, L
    EUROPEAN HEART JOURNAL, 1995, 16 (09) : 1215 - 1222
  • [30] Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry
    Giguere, Steeve
    Sanchez, L. Chris
    Shih, Andre
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2014, 24 (05) : 529 - 535