EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM

被引:65
|
作者
DIMICH, I
SINGH, PP
ADELL, A
HENDLER, M
SONNENKLAR, N
JHAVERI, M
机构
[1] MT SINAI MED SCH,DEPT ANESTHESIOL,NEW YORK,NY
[2] CITY HOSP CTR,ELMHURST,NY 11373
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1991年 / 38卷 / 08期
关键词
ANESTHESIA; -; OBSTETRICAL; NEONATES; MEASUREMENT TECHNIQUES - OXIMETERS; MONITORING; OXYGEN; OXYGEN - BLOOD LEVELS; MEASUREMENT;
D O I
10.1007/BF03008616
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.
引用
收藏
页码:985 / 988
页数:4
相关论文
共 37 条
  • [11] ANESTHETIC-POSTOPERATIVE MORPHINE REGIMENS FOR CESAREAN-SECTION AND POSTOPERATIVE OXYGEN-SATURATION MONITORED BY A TELEMETRIC PULSE OXIMETRY NETWORK FOR 24 CONTINUOUS HOURS
    PAN, PH
    JAMES, CF
    JOURNAL OF CLINICAL ANESTHESIA, 1994, 6 (02) : 124 - 128
  • [12] OXYGEN-CONSUMPTION AND MIXED VENOUS OXYGEN-SATURATION MONITORING DURING ORTHOTOPIC LIVER-TRANSPLANTATION
    SPIESS, BD
    TUMAN, KJ
    MCCARTHY, RJ
    LOGAS, WG
    LUBENOW, TR
    WILLIAMS, J
    SANKRAY, H
    FOSTER, P
    JOURNAL OF CLINICAL MONITORING, 1992, 8 (01): : 7 - 11
  • [13] Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients
    Hinkelbein, Jochen
    Genzwuerker, Harald V.
    Sogl, Reiner
    Fiedler, Fritz
    RESUSCITATION, 2007, 72 (01) : 82 - 91
  • [14] EFFECTS OF ANEMIA ON PULSE OXIMETRY AND CONTINUOUS MIXED VENOUS HEMOGLOBIN SATURATION MONITORING IN DOGS
    LEE, S
    TREMPER, KK
    BARKER, SJ
    ANESTHESIOLOGY, 1991, 75 (01) : 118 - 122
  • [15] NONINVASIVE MONITORING OF REGIONAL CEREBRAL OXYGEN-SATURATION - EXPERIENCES IN INTENSIVE-CARE MEDICINE
    LITSCHER, G
    SCHWARZ, G
    JOBSTMANN, R
    KLEIN, G
    NEUMANN, I
    PRIETL, B
    BIOMEDIZINISCHE TECHNIK, 1995, 40 (03): : 70 - 75
  • [16] Reference Interval for Pulse Oxygen Saturation in Neonates at Different Altitudes: A Systematic Review
    Wang, Bo
    Zhang, Jia
    Wu, Ya-Zhen
    Lu, Zhi-Hui
    Wang, Na
    Yu, Zhang-Bin
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [17] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION FOR DETECTING ALTERATIONS IN CARDIAC-OUTPUT AFTER DISCONTINUATION OF CARDIOPULMONARY BYPASS
    INOMATA, S
    NISHIKAWA, T
    TAGUCHI, M
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) : 11 - 16
  • [18] Comparison of human smartwatch and transmittance pulse oximetry for evaluating peripheral oxygen saturation in anesthetized dogs
    Senocak, M. G.
    Okur, S.
    Ersoz, U.
    Yanmaz, L. E.
    Kocaman, Y.
    Turgut, F.
    Bedir, A. G.
    Orhun, O. T.
    IRANIAN JOURNAL OF VETERINARY RESEARCH, 2024, 25 (02)
  • [19] ARTERIAL OXYGEN-SATURATION DURING INDUCTION OF ANESTHESIA AND LARYNGEAL MASK INSERTION - PROSPECTIVE EVALUATION OF 4 TECHNIQUES
    HAYNES, SR
    ALLSOP, JR
    GILLIES, GWA
    BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (05) : 519 - 522
  • [20] A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients
    Ebmeier, S. J.
    Barker, M.
    Bacon, M.
    Beasley, R. C.
    Bellomo, R.
    Chong, C. Knee
    Eastwood, G. M.
    Gilchrist, J.
    Kagaya, H.
    Pilcher, J.
    Reddy, S. K.
    Ridgeon, E.
    Sarma, N.
    Spragas, S.
    Tanaka, A.
    Tweedie, M.
    Weatherall, M.
    Young, P. J.
    ANAESTHESIA AND INTENSIVE CARE, 2018, 46 (03) : 297 - 303