Medial Pivot in Total Knee Arthroplasty: Literature Review and Our First Experience

被引:51
作者
Sabatini, Luigi [1 ]
Risitano, Salvatore [2 ]
Parisi, Gennaro [2 ]
Tosto, Ferdinando [2 ]
Indelli, Pier Francesco [3 ]
Atzori, Francesco [4 ]
Masse, Alessandro [1 ]
机构
[1] CTO Hosp, Dept Orthopaed & Traumatol, Citta Salute & Sci Torino, Via Zuretti 29, I-10126 Turin, Italy
[2] Univ Turin, Turin, Italy
[3] Stanford Univ, Sch Med, Dept Orthopaed Surg, Palo Alto, CA 94304 USA
[4] Cottolengo Hosp, Dept Orthopaed, Turin, Italy
关键词
medial pivot insert; Medial Congruent insert; total knee arthroplasty;
D O I
10.1177/1179544117751431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Traditional total knee implants designs, usually, are not able to reproduce the physiological kinematics of the knee, leaving almost 20% of the patients, those who underwent a total knee arthroplasty (TKA), not fully satisfied. Modern inserts are nowadays designed with a fully congruent medial compartment to reproduce the normal medial pivoting biomechanics of the knee. The aim of this article was to evaluate preliminary clinical improvement using the Medial Congruent (MC) insert as specific level of constraint. MATERIALS AND METHODS: A total of 10 consecutive patients have been enrolled in this study and treated using an MC tibial polyethylene insert. The Oxford Knee Score (OKS) and the Knee Society Score (KSS) have been assessed preoperatively and at 3-month, 6-month, and 1-year follow-up (FU) and used as validated measurements to evaluate early clinical improvements. Postoperative radiological examination was reviewed looking for radiolucent lines or loosening of the components. RESULTS: Average improvement in OKS was from 19.5 to 41.2, whereas KSS improved with an average score from 64.7 preoperatively to 167.5 at the final FU showing good to excellent results in 95% of the treated knees. Evaluating the range of motion, the average maximum active movement was 124 degrees and none of the patients needing for a revision surgery or manipulation under anesthesia. No complications were observed at the final FU as septic or aseptic loosening or vascular or neurologic injury. DISCUSSION AND CONCLUSIONS: Medial Congruent insert showed good to excellent clinical results at 1-year FU. Range of motion and subjective outcomes were satisfying and comparable with results obtained in literature using traditional TKA design.
引用
收藏
页数:4
相关论文
共 27 条
[1]  
Blaha JD, 2002, ORTHOPEDICS, V25, P963
[2]  
Choi Young-Joon, 2016, Knee Surg Relat Res, V28, P1, DOI 10.5792/ksrr.2016.28.1.1
[3]   Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[4]   Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57
[5]   The movement of the normal tibio-femoral joint [J].
Freeman, MAR ;
Pinskerova, V .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :197-208
[6]   Knee Arthroplasty With a Medially Conforming Ball-and-Socket Tibiofemoral Articulation Provides Better Function [J].
Hossain, Fahad ;
Patel, Shelain ;
Rhee, Shin-Jae ;
Haddad, Fares Sami .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (01) :55-63
[7]   Relationship between Tibial Baseplate Design and Rotational Alignment Landmarks in Primary Total Knee Arthroplasty [J].
Indelli, Pier Francesco ;
Graceffa, Angelo ;
Baldini, Andrea ;
Payne, Brielle ;
Pipino, Gennaro ;
Marcucci, Massimiliano .
ARTHRITIS, 2015,
[8]  
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[9]   Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using 'interventional' MRI [J].
Johal, P ;
Williams, A ;
Wragg, P ;
Hunt, D ;
Gedroyc, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :269-276
[10]   In vivo fluoroscopic analysis of the normal human knee [J].
Komistek, RD ;
Dennis, DA ;
Mahfouz, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :69-81