Visual Outcomes and Refractive Status after Combined Silicone Oil Removal/Cataract Surgery with Intraocular Lens Implantation

被引:22
作者
Al-Habboubi, Hussain F. [1 ,2 ]
Al-Zamil, Waseem [2 ]
Al-Habboubi, Ali A. [3 ]
Khandekar, Rajiv [4 ]
机构
[1] King Khalid Eye Specialist Hosp, Anterior Segment Unit, Riyadh, Saudi Arabia
[2] Univ Dammam, Dept Ophthalmol, Dammam, Saudi Arabia
[3] Taibah Univ, Dept Ophthalmol, Madinah, Saudi Arabia
[4] King Khalid Eye Specialist Hosp, Res Dept, POB 7191,Aruba Rd, Riyadh 11462, Saudi Arabia
关键词
Cataract Extraction; Intraocular Lens Implantation; Refractive Errors; Silicone Oil;
D O I
10.4103/jovr.jovr_252_16
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate refractive status and identify predictors of surgical success following a combined silicone oil removal/cataract surgery with intraocular lens (IOL) implantation procedure. Methods: In this single-armed, retrospective study, we reviewed patients who underwent vitreoretinal surgery followed by a combined silicone oil removal/cataract surgery procedure between 2009 and 2013. Preoperative data included patient demographics, refractive status, IOL power, and axial length (measured with the IOL Master). Postoperative data were obtained from the 8-week follow-up visit and from the last follow-up visit attended that included refractive error (RE) evaluation (e.g., myopic, hyperopic, and astigmatic). Associations between variables and refractive status were examined. Blindness was defined as a best-corrected visual acuity (BCVA) worse than 3/60. Results: Nighty-eight eyes were ultimately included in analyses. Following surgery, 37.0% of eyes achieved BCVA better than 6/18. The incidence of blindness (BCVA worse than 3/60) was reduced from 47.0% before surgery to 17.3% after surgery. Additionally, 33.7% of eyes did not require refractive correction. Forty-two percent of eyes were under-corrected (>0.5 D hyperopia) following surgery. Age, gender, silicone oil viscosity, axial length, IOL type, initial vitreoretinal pathology, surgeon, and IOL calculation formula were not significantly associated with surgical outcomes (all P > 0.05). Conclusion: A combined silicone oil removal/cataract surgery with IOL implantation procedure restored functional vision in approximately one-third of cases. However, nearly half of patients were under-corrected. Unfortunately, we did not identify any factors that predicted surgical success.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 14 条
[1]   Cataract and surgery for cataract [J].
Allen, David ;
Vasavada, Abhay .
BMJ-BRITISH MEDICAL JOURNAL, 2006, 333 (7559) :128-132
[2]   VITREORETINAL SURGERY WITH SILICONE OIL TAMPONADE IN PRIMARY UNCOMPLICATED RHEGMATOGENOUS RETINAL DETACHMENT: Clinical Outcomes and Complications [J].
Antoun, Joelle ;
Azar, Georges ;
Jabbour, Elyse ;
Kourie, Hampig Raphael ;
Slim, Elise ;
Schakal, Alexandre ;
Jalkh, Alex .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (10) :1906-1912
[3]   Complications of silicone oil tamponade [J].
Baillif, S. ;
Gastaud, P. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2014, 37 (03) :259-265
[4]   Silicone Oil: Different Physical Proprieties and Clinical Applications [J].
Barca, Francesco ;
Caporossi, Tomaso ;
Rizzo, Stanislao .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[5]   Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal [J].
El-Baha, SM ;
El-Samadoni, A ;
Idris, HF ;
Rashad, KM .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (07) :622-626
[6]   The problems of biometry in combined silicone oil removal and cataract extraction - A clinical trial [J].
Ghoraba, HH ;
El-Dorghamy, AA ;
Atia, AF ;
Yassin, ABDEAI .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (05) :589-596
[7]   Cataract surgery practice patterns in the United States Veterans Health Administration [J].
Greenberg, Paul B. ;
Havnaer, Annika ;
Oetting, Thomas A. ;
Garcia-Ferrer, Francisco J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04) :705-709
[8]   Refractive outcome of silicone oil removal and intraocular lens implantation using her interferometry [J].
Habibabadi, HF ;
Hashemi, H ;
Jalali, KH ;
Amini, A ;
Esfahani, MR .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2005, 25 (02) :162-166
[9]   Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis [J].
Helaly, Hany A. ;
El-Hifnawy, Mohammad A. M. ;
Shaheen, Mohamed Shafik ;
Abou El-Kheir, Amr F. .
MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (01) :122-128
[10]  
Janco L, 2014, Cesk Slov Oftalmol, V70, P178