SAMPLE PREPARATION APPROACHES FOR ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC CERTIFICATION OF REFERENCE MATERIALS

被引:22
作者
BEARY, ES
PAULSEN, PJ
FASSETT, JD
机构
[1] National Institute of Standards and Technology, Gaithersburg
关键词
ISOTOPE DILUTION; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; SAMPLE PREPARATION; CHEMICAL SEPARATIONS; RATIO MEASUREMENT;
D O I
10.1039/ja9940901363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ratio measurements can be made by inductively coupled plasma mass spectrometry (ICP-MS) with precisions approaching 0.1-0.2% relative standard deviation, under carefully controlled conditions. This capability is well suited to isotope dilution quantification, since quantitative data are based solely on ratio measurements. Conversion of the precision of isotopic ratio measurements to accuracy requires attention to both the operation of the ICP mass spectrometer and to the sample preparation procedures. The concentration of Mg, Cd, Mo and Pb were determined in synthetic samples with average precision and accuracy of < 0.15%. Although more extensive chemistry was required, analytical precision was better than 0.15% for Cu and Cd in zinc ore and for Cu and Mo in domestic sludge.
引用
收藏
页码:1363 / 1369
页数:7
相关论文
共 37 条
[1]   DETERMINATION OF URANIUM AND THORIUM CONCENTRATIONS IN SOILS - COMPARISON OF ISOTOPE-DILUTION SECONDARY ION MASS-SPECTROMETRY AND ISOTOPE-DILUTION THERMAL IONIZATION MASS-SPECTROMETRY [J].
ADRIAENS, AG ;
FASSETT, JD ;
KELLY, WR ;
SIMONS, DS ;
ADAMS, FC .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :2945-2950
[2]   PROPAGATION OF UNCERTAINTIES IN ISOTOPE-DILUTION MASS-SPECTROMETRY USING PULSE COUNTING DETECTION [J].
ADRIAENS, AG ;
KELLY, WR ;
ADAMS, FC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :660-663
[3]   REDUCTION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY CRYOGENIC DESOLVATION [J].
ALVES, LC ;
WIEDERIN, DR ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1164-1169
[4]   SELECTIVE APPLICATION OF CHEMICAL SEPARATIONS TO ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC ANALYSES OF STANDARD REFERENCE MATERIALS [J].
BEARY, ES ;
PAULSEN, PJ .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1602-1608
[5]   DETERMINATION OF SELENIUM AND TELLURIUM IN COPPER STANDARD REFERENCE MATERIALS USING STABLE ISOTOPE-DILUTION SPARK SOURCE-MASS SPECTROMETRY [J].
BEARY, ES ;
PAULSEN, PJ ;
LAMBERT, GM .
ANALYTICAL CHEMISTRY, 1988, 60 (07) :733-736
[6]   A COMPARISON OF ISOTOPE-DILUTION MASS-SPECTROMETRIC METHODS FOR THE ASSAY OF COPPER IN COPPER ORE REFERENCE MATERIALS [J].
BEARY, ES ;
BRLETIC, KA ;
PAULSEN, PJ ;
MOODY, JR .
ANALYST, 1987, 112 (04) :441-444
[8]   DETERMINATION OF ULTRATRACE NEODYMIUM IN HIGH-PURITY LANTHANUM COMPOUNDS BY HIGH-ACCURACY ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC ANALYSIS WITH CHEMICAL PRECONCENTRATION [J].
BEARY, ES ;
PAULSEN, PJ .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :431-439
[9]   DETERMINATION OF TRACE-METALS IN A RIVER WATER REFERENCE MATERIAL BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
MYKYTIUK, AP ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :778-783
[10]  
DEBIEVRE P, 1993, ANAL PROC, V30, P328, DOI DOI 10.1039/AP9933000328