Cobb Angle Measurement of Scoliosis Using Computer Measurement of Digitally Acquired Radiographs-Intraobserver and Interobserver Variability

被引:24
作者
Srinivasalu, S. [1 ]
Modi, Hitesh N. [1 ]
SMehta, Satyen [1 ]
Suh, Seung-Woo [1 ]
Chen, Ting [1 ]
Murun, Temuujin [1 ]
机构
[1] Korea Univ Guro Hosp, Scoliosis Res Inst, Dept Orthped Surg, Seoul, South Korea
关键词
Scoliosis; Digital imaging; Cobb angle; Intraobserver and interobserver variability;
D O I
10.4184/asj.2008.2.2.90
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: We evaluated computer assisted digital measurement of radiographic parameters in patients with idiopathic scoliosis. Purpose: To assess the reliability of digital measurements. Overview of Literatures: Various authors analyzed scoliotic deformities by conventional radiographs, but very few studies have addressed the reliability of digital radiographic measurement using computer software. Methods: Three independent, blinded observers measured 318 whole spine pre-operative antero-posterior radiograms of children with varying degrees of idiopathic scoliosis. Only one curve per radiograph was measured. Each observer measured the Cobb angle three times with a 1-week gap between each measurement. The computer system, picture archiving and communication system (PACS, PiViewSTAR version 5) was used in all cases. The end vertebrae were pre-selected to avoid this as a potential source of error. The results were statistically analyzed for intraobserver and interobserver reliability and variability. Results: The 95% confidence intervals for intraobserver and interobserver variability were +/- 1.30 and +/- 1.260, respectively. There was better reliability in larger curves. Conclusions: Measurement using a digitized system may help to minimize measurement discrepancies by eliminating an intrinsic cause of error.
引用
收藏
页码:90 / 93
页数:4
相关论文
共 13 条
[1]   MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION [J].
CARMAN, DL ;
BROWNE, RH ;
BIRCH, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :328-333
[2]   The reliability of quantitative analysis on digital images of the scoliotic spine [J].
Cheung, J ;
Wever, DJ ;
Veldhuizen, AG ;
Klein, JP ;
Verdonck, B ;
Nijlunsing, R ;
Cool, JC ;
Van Horn, JR .
EUROPEAN SPINE JOURNAL, 2002, 11 (06) :535-542
[3]  
Cobb JR, 1948, AM ACADEMY ORTHOPAED, V7, P261
[4]   Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual [J].
Dang, NR ;
Moreau, MJ ;
Hill, DL ;
Mahood, JK ;
Raso, J .
SPINE, 2005, 30 (09) :1064-1069
[5]   REPRODUCIBILITY AND RESPONSIVENESS OF HEALTH-STATUS MEASURES - STATISTICS AND STRATEGIES FOR EVALUATION [J].
DEYO, RA ;
DIEHR, P ;
PATRICK, DL .
CONTROLLED CLINICAL TRIALS, 1991, 12 (04) :S142-S158
[6]   Comparison of manual and digital measurements in adolescent idiopathic scoliosis [J].
Kuklo, Timothy R. ;
Potter, Benjamin K. ;
Schroeder, Teresa M. ;
O'Brien, Michael F. .
SPINE, 2006, 31 (11) :1240-1246
[7]   Reliability analysis for digital adolescent idiopathic scoliosis measurements [J].
Kuklo, TR ;
Potter, BK ;
O'Brien, MF ;
Schroeder, TM ;
Lenke, LG ;
Polly, DW .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (02) :152-159
[8]   Reliability analysis for manual adolescent idiopathic scoliosis measurements [J].
Kuklo, TR ;
Potter, BK ;
Polly, DW ;
O'Brien, MF ;
Schroeder, TM ;
Lenke, LG .
SPINE, 2005, 30 (04) :444-454
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]   MEASUREMENT OF THE COBB ANGLE ON RADIOGRAPHS OF PATIENTS WHO HAVE SCOLIOSIS - EVALUATION OF INTRINSIC ERROR [J].
MORRISSY, RT ;
GOLDSMITH, GS ;
HALL, EC ;
KEHL, D ;
COWIE, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :320-327