REVISION HIP ARTHROPLASTY WITH CUSTOM TRIFLANGE IMPLANT IN PATIENT WITH PELVIC DISCONTINUITY (case report)

被引:0
作者
Tikhilov, R. M. [1 ,2 ]
Shubnyakov, I. I. [1 ]
Kovalenko, A. N. [1 ]
Bilyk, C. C. [1 ]
Tsybin, A. N. [1 ]
Denisov, A. O. [1 ]
Dmitrevich, G. D. [3 ]
Vopilovsky, P. N. [4 ]
机构
[1] Vreden Russian Res Inst Traumatol & Orthoped, Ul Ak Baykova 8, St Petersburg 195427, Russia
[2] Mechnikov North Western State Med Univ, Kirochnaya Ul 41, St Petersburg 191015, Russia
[3] St Petersburg Electrotech Univ LETI, Ul Prof Popova 5, St Petersburg 197376, Russia
[4] Peter Great St Petersburg Polytech Univ, Ul Politekh Skaya 29, St Petersburg 195251, Russia
来源
TRAVMATOLOGIYA I ORTOPEDIYA ROSSII | 2016年 / 22卷 / 01期
关键词
acetabular defect; pelvic discontinuity; custom implant;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The most challenge of the revision hip arthroplasty is pelvic discontinuity (defect type IV by AAOS classification). In such cases it is very difficult to provide secure fixation of the acetabular component due to limited contact with host bone and mobility of bone fragments. Custom triflange acetabular components(CTAC) is a perspective method of patient management in this cases. CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We present case report of the patient - female 48 years old with aseptic loosening of the acetabular component and pelvic discontinuity. Chronic pelvis discontinuity developed due to conservative treatment of the associative fracture of the acetabulum. Four years after injury total hip arthroplasty using Burch-Schneider.age was performed. After seven years - aseptic loosening of the acetabular component and revision surgery with antiprotrusion revision implant. In two years after last surgery - aseptic loosening of the acetabular component and extensive ilium bone defect along with caudal hip bone part medial displacement and pelvic ring deformity. Due to high difficulty of revision total hip arthroplasty using modular acetabular cup and antiprotrusion implants we perform replacement with custom triflange acetabular component
引用
收藏
页码:108 / 116
页数:9
相关论文
共 20 条
[1]   Management of pelvic discontinuity in revision total hip arthroplasty: a review of the literature [J].
Abdelnasser, Mohammad K. ;
Klenke, Frank M. ;
Whitlock, Patrick ;
Khalil, Aly M. ;
Khalifa, Yaser E. ;
Ali, Hassan M. ;
Siebenrock, Klaus A. .
HIP INTERNATIONAL, 2015, 25 (02) :120-126
[2]   Promising Mid-term Results With a Cup-cage Construct for Large Acetabular Defects and Pelvic Discontinuity [J].
Amenabar, Tomas ;
Rahman, Wael A. ;
Hetaimish, Bandar M. ;
Kuzyk, Paul R. ;
Safir, Oleg A. ;
Gross, Allan E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) :408-414
[3]  
[Anonymous], 2015, TRAVM ORT ZAB SOST T
[4]  
[Anonymous], 2009, TRAVM ORT ZAB SOST T
[5]   Pelvic discontinuity in revision total hip arthroplasty [J].
Berry, DJ ;
Lewallen, DG ;
Hanssen, AD ;
Cabanela, ME .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1692-1702
[6]  
Berry DJ, 2004, CLIN ORTHOP RELAT R, P106
[7]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[8]   Revision total hip arthroplasty for pelvic discontinuity [J].
DeBoer, David K. ;
Christie, Michael J. ;
Brinson, Martha F. ;
Morrison, J. Craig .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :835-840
[9]  
Dianov SV, 2015, TRAVMATOLOGIA ORTOPE, P92
[10]  
Eggli S, 2002, CLIN ORTHOP RELAT R, P136