Predictors of residual flow in embolized intracranial ruptured aneurysms at early follow-up

被引:4
|
作者
Serafin, Zbigniew [1 ]
Strzesniewski, Piotr [1 ]
Beuth, Wojciech [2 ]
机构
[1] Nicolaus Copernicus Univ, Collegium Medicum Bydgoszcz, Dept Radiol & Diagnost Imaging, Bydgoszcz, Poland
[2] Higher Sch Humanities & Econ Wloclawek, Fac Hlth Sci, Wloclawek, Poland
关键词
Follow-up Imaging; Embolization; Therapeutic; Intracranial Aneurysm;
D O I
10.12659/PJR.889919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The possibility of recanalization and the need for retreatment are the most important drawbacks of intracranial aneurysm embolization. The purpose of the study was to prospectively analyze the results of early follow-up angiography of embolized ruptured aneurysms in an attempt to determine factors predicting the presence of residual flow. Material/Methods: Evaluation included 72 patients with 72 aneurysms, which were followed-up 3 months after the treatment. Analysis of residual flow predictors included: age and gender, clinical state in Hunt-Hess scale, aneurysm localization, aneurysm three dimensions and volume, neck width, sac-to-neck ratio, initial result of embolization, number of coils used and the use of hydrogel coils and stents. Results: Mean sac diameter was 6.5 +/- 3.9 mm, and mean neck width was 2.9 +/- 1.4 mm. Follow-up angiography presented residual flow in 26 aneurysms (36.1%): class 2 in 8 aneurysms (11.1%), and class 3 in 18 cases (25.0%). Stable aneurysm filling was observed in 45 cases (62.5%), progression of residual flow in 25 cases (34.7%), and regression in 2 cases (2.8%). According to ROC analysis independent predictors of residual flow were aneurysm neck diameter (AUC 0.857, 95% CI: 0.755-0.928, p<0.0001) and sac-to-neck ratio (AUC 0.817, 95% CI: 0.708-0.898, p<0.0001). Cut-off point of the ROC curve was established at 2.8 mm for neck diameter, and 1.73 for sac-to-neck ratio. Conclusions: Aneurysm neck diameter and sac-to-neck ratio are independently related to the residual flow in embolized ruptured aneurysms at early follow-up.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 50 条
  • [21] Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms
    Papke, Karsten
    Brassel, Friedhelm
    EUROPEAN RADIOLOGY, 2006, 16 (09) : 2051 - 2066
  • [22] Coil Embolization of Intracranial Aneurysms: A Six-Month Follow-Up Study
    Miri, Mojtaba
    Ghanaati, Hossein
    Salamati, Payman
    Nik, Hojat Ebrahimi
    Jalali, Amir Hossein
    Saeednejad, Mina
    Firouznia, Kavous
    IRANIAN JOURNAL OF RADIOLOGY, 2015, 12 (03) : 1 - 6
  • [23] Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms
    Karsten Papke
    Friedhelm Brassel
    European Radiology, 2006, 16 : 2051 - 2066
  • [24] Computerized Occlusion Rating of Embolized Ruptured Intracranial Aneurysms: Relation to Intra- and Postinterventional Aneurysm Rehemorrhage
    Milavec, Helena
    Gruber, Andreas
    Schuster, Ernst
    Lahnsteiner, Eva
    Dorfer, Christian
    Krawagna, Maximilian
    Knosp, Engelbert
    Sherif, Camillo
    CEREBRAL VASOSPASM: NEUROVASCULAR EVENTS AFTER SUBARACHNOID HEMORRHAGE, 2013, 115 : 119 - +
  • [25] Stent-assisted coiling of unruptured intracranial aneurysms: Long-term follow-up in 164 patients with 183 aneurysms
    Mine, Benjamin
    Aljishi, Ali
    D'Harcour, Jean-Bernard
    Brisbois, Denis
    Collignon, Laurent
    Lubicz, Boris
    JOURNAL OF NEURORADIOLOGY, 2014, 41 (05) : 322 - 328
  • [26] CORTICAL BLOOD-FLOW RECORDED DURING EARLY OR DELAYED SURGERY FOR RUPTURED INTRACRANIAL ANEURYSMS
    VIALE, GL
    COSSU, M
    CELLA, F
    BALESTRERO, M
    ROSSI, A
    MASONI, D
    ACTA NEUROCHIRURGICA, 1994, 131 (1-2) : 1 - 5
  • [27] Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study
    Berge, J.
    Biondi, A.
    Machi, P.
    Brunel, H.
    Pierot, L.
    Gabrillargues, J.
    Kadziolka, K.
    Barreau, X.
    Dousset, V.
    Bonafe, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1150 - 1155
  • [28] Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms
    John, Seby
    Bain, Mark D.
    Hui, Ferdinand K.
    Hussain, M. Shazam
    Masaryk, Thomas J.
    Rasmussen, Peter A.
    Toth, Gabor
    NEUROSURGERY, 2016, 78 (06) : 862 - 867
  • [29] Natural History of Unruptured Intracranial Aneurysms A Long-term Follow-up Study
    Juvela, Seppo
    Poussa, Kristiina
    Lehto, Hanna
    Porras, Matti
    STROKE, 2013, 44 (09) : 2414 - 2421
  • [30] Long-term angiographic follow-up of intracranial aneurysms treated with the intracranial neuroform stent reconstruction.
    Zhu, Chun-Yan
    Liu, Cun-Xiang
    Liu, Ji-Xiang
    Zhou, Tao
    Li, Cong-Hui
    Yang, Song-Tao
    Gao, Bu-Lang
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (15): : 6700 - 6705