AN IMPROVED VOLTAMMETRIC METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF URIC-ACID WITH ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODES

被引:84
作者
CAI, XH
KALCHER, K
NEUHOLD, C
OGOREVC, B
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,UNIV PLATZ 1,A-8010 GRAZ,AUSTRIA
[2] NATL INST CHEM,LJUBLJANA,SLOVENIA
关键词
D O I
10.1016/0039-9140(94)80146-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon paste electrodes, preanodized in alkaline medium at 1.4 V vs SCE for a short period of time, exhibit a great shift of the oxidation potential of uric acid in cathodic direction and a marked enhancement of its current response, compared to unpretreated electrodes. These effects are dependent on the preanodization potential and the time imposed on the electrodes as well as on the alkalinity of the supporting electrolyte. The enhanced voltammetric response can be used to determine uric acid in the concentration range of 5.0-4.0 x 10(4) mug/l (3.0 x 10(-8)-2.4 x 10(-4)M) with a detection limit (3sigma) of 2.0 mug/l (1.2 x 10(-8)M). Ascorbic acid in less than 30-fold excess does not interfere. For multiple determinations (5 runs), the relative standard deviation is 2.1% at a concentration of 1 mg/l uric acid. The proposed procedure can be used to determine uric acid in human urine and serum without any preliminary treatment of the samples in an accurate, rapid and simple way.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 32 条
[1]   STUDY OF ELECTROCHEMICAL OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE [J].
BLAEDEL, WJ ;
JENKINS, RA .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1337-1343
[2]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[3]   ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2310-2314
[4]  
ENGSTROM RC, 1986, ANAL CHEM, V58, P136
[5]   VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1992, 117 (08) :1299-1303
[6]   AMPEROMETRIC SENSOR FOR HYPOXANTHINE AND XANTHINE BASED ON THE DETECTION OF URIC-ACID [J].
GONZALEZ, E ;
PARIENTE, F ;
LORENZO, E ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1991, 242 (02) :267-273
[7]  
Hart J. P., 1990, ELECTROANALYSIS BIOL, P51
[8]   SINGLE COLUMN HPLC METHOD FOR DRUG LEVEL MONITORING BY DIRECT PLASMA SAMPLE INJECTION - APPLICATION TO 6-MERCAPTOPURINE, THEOPHYLLINE AND CHLORPROMAZINE [J].
IMAI, H ;
YOSHIDA, H ;
MASUJIMA, T ;
MORITA, I ;
MATSUURA, K ;
NAKAMARU, A ;
KATAYAMA, K ;
MATSUO, H .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1983, 16 (14) :1109-1120
[9]  
IMAI H, 1981, BUNSEKI KAGAKU, V30, P561
[10]   IMPROVED DATA-PROCESSING FOR ELECTROANALYTICAL MEASUREMENTS [J].
KALCHER, K ;
JORDE, C .
COMPUTERS & CHEMISTRY, 1986, 10 (03) :201-218